{
"description": "Legal authenticator (The person taking responsibility for the medical content of the document).\\nSection A1.7 of the eHN guideline.",
"_filename": "StructureDefinition-LegalAuthenticatorCz.json",
"package_name": "hl7.fhir.cz.lab",
"date": "2026-08-14T16:12:29+02:00",
"derivation": "specialization",
"publisher": "HL7 Czech Republic",
"fhirVersion": "4.0.1",
"jurisdiction": [ {
"coding": [ {
"code": "CZ",
"system": "urn:iso:std:iso:3166",
"display": "Czechia"
} ]
} ],
"name": "LogEnLegalAuthenticatorLabEhnCz",
"abstract": false,
"type": "https://hl7.cz/fhir/lab/StructureDefinition/LegalAuthenticatorCz",
"experimental": null,
"resourceType": "StructureDefinition",
"title": "A.1.7 - Legal authenticator",
"package_version": "1.0.0",
"snapshot": {
"element": [ {
"id": "LegalAuthenticatorCz",
"max": "*",
"min": 0,
"base": {
"max": "*",
"min": 0,
"path": "Base"
},
"path": "LegalAuthenticatorCz",
"short": "A.1.7 - Legal authenticator",
"definition": "Legal authenticator (The person taking responsibility for the medical content of the document).\nSection A1.7 of the eHN guideline.",
"isModifier": false
}, {
"id": "LegalAuthenticatorCz.identifier",
"max": "*",
"min": 1,
"base": {
"max": "*",
"min": 1,
"path": "LegalAuthenticatorCz.identifier"
},
"path": "LegalAuthenticatorCz.identifier",
"type": [ {
"code": "Identifier"
} ],
"short": "A.1.7.1 Legal authenticator identifier",
"definition": "Identification number of the healthcare professional responsible for the overall content of the document. Either an internal identifier assigned by the health care provider's institution or (preferably) a national health professional ID such as a license or registration number. The chief medical officer or head of department who is responsible for the discharge report as a whole. May be the same as the certifying officer."
}, {
"id": "LegalAuthenticatorCz.name",
"max": "1",
"min": 1,
"base": {
"max": "1",
"min": 1,
"path": "LegalAuthenticatorCz.name"
},
"path": "LegalAuthenticatorCz.name",
"type": [ {
"code": "HumanName"
} ],
"short": "A.1.7.2 Legal authenticator name",
"definition": "Full name and identification of the person responsible for the content of the document."
}, {
"id": "LegalAuthenticatorCz.organization",
"max": "1",
"min": 1,
"base": {
"max": "1",
"min": 1,
"path": "LegalAuthenticatorCz.organization"
},
"path": "LegalAuthenticatorCz.organization",
"type": [ {
"code": "Organization",
"profile": [ "https://hl7.cz/fhir/core/StructureDefinition/cz-organization-core" ]
} ],
"short": "A.1.7.3 Legal authenticator organization",
"definition": "The name and identification details of the healthcare facility represented by the person responsible for the content of the document."
}, {
"id": "LegalAuthenticatorCz.dateTime",
"max": "1",
"min": 1,
"base": {
"max": "1",
"min": 1,
"path": "LegalAuthenticatorCz.dateTime"
},
"path": "LegalAuthenticatorCz.dateTime",
"type": [ {
"code": "dateTime"
} ],
"short": "A.1.7.4 Authentication date and time",
"definition": "Date and time when the document was authorized."
} ],
"extension": [ {
"url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
"valueString": "4.0.1"
} ]
},
"status": "active",
"id": "de04bedb-bbe5-470a-a78d-da10140d2f84",
"kind": "logical",
"url": "https://hl7.cz/fhir/lab/StructureDefinition/LegalAuthenticatorCz",
"version": "1.0.0",
"differential": {
"element": [ {
"id": "LegalAuthenticatorCz",
"path": "LegalAuthenticatorCz",
"short": "A.1.7 - Legal authenticator",
"definition": "Legal authenticator (The person taking responsibility for the medical content of the document).\nSection A1.7 of the eHN guideline."
}, {
"id": "LegalAuthenticatorCz.identifier",
"max": "*",
"min": 1,
"path": "LegalAuthenticatorCz.identifier",
"type": [ {
"code": "Identifier"
} ],
"short": "A.1.7.1 Legal authenticator identifier",
"definition": "Identification number of the healthcare professional responsible for the overall content of the document. Either an internal identifier assigned by the health care provider's institution or (preferably) a national health professional ID such as a license or registration number. The chief medical officer or head of department who is responsible for the discharge report as a whole. May be the same as the certifying officer. "
}, {
"id": "LegalAuthenticatorCz.name",
"max": "1",
"min": 1,
"path": "LegalAuthenticatorCz.name",
"type": [ {
"code": "HumanName"
} ],
"short": "A.1.7.2 Legal authenticator name",
"definition": "Full name and identification of the person responsible for the content of the document."
}, {
"id": "LegalAuthenticatorCz.organization",
"max": "1",
"min": 1,
"path": "LegalAuthenticatorCz.organization",
"type": [ {
"code": "Organization",
"profile": [ "https://hl7.cz/fhir/core/StructureDefinition/cz-organization-core" ]
} ],
"short": "A.1.7.3 Legal authenticator organization",
"definition": "The name and identification details of the healthcare facility represented by the person responsible for the content of the document."
}, {
"id": "LegalAuthenticatorCz.dateTime",
"max": "1",
"min": 1,
"path": "LegalAuthenticatorCz.dateTime",
"type": [ {
"code": "dateTime"
} ],
"short": "A.1.7.4 Authentication date and time",
"definition": "Date and time when the document was authorized."
} ]
},
"contact": [ {
"name": "HL7 Czech Republic",
"telecom": [ {
"value": "https://hl7.cz",
"system": "url"
} ]
} ],
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/Base"
}