PackagesCanonicalsLogsProblems
    Packages
    de.medizininformatikinitiative.kerndatensatz.kardiologie@2026.0.0-alpha.1
    https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-device
{
  "description": "Profil zur Abbildung eines implantierten Herzschrittmachers, Defibrillators oder ventrikulären Unterstützungssystems.",
  "_filename": "StructureDefinition-mii-pr-kardio-device.json",
  "package_name": "de.medizininformatikinitiative.kerndatensatz.kardiologie",
  "date": "2025-09-05",
  "derivation": "constraint",
  "publisher": "Medizininformatik Initiative",
  "fhirVersion": "4.0.1",
  "name": "MII_PR_Kardio_Device",
  "abstract": false,
  "type": "Device",
  "experimental": "false",
  "resourceType": "StructureDefinition",
  "title": "MII PR Kardio Device",
  "package_version": "2026.0.0-alpha.1",
  "status": "active",
  "id": "be2fa316-880d-4447-999c-425face8e3fb",
  "kind": "resource",
  "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-device",
  "version": "2026.0.0-alpha.1",
  "differential": {
    "element": [ {
      "id": "Device.status",
      "path": "Device.status",
      "mustSupport": true
    }, {
      "id": "Device.type",
      "min": 1,
      "path": "Device.type",
      "binding": {
        "strength": "required",
        "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/ValueSet/mii-vs-kardio-geraetetyp-snomedct"
      },
      "comment": "Der Typ soll mit einem SNOMED-Code angegeben werden.\r\nFür ACRIBiS müssen die folgenden Codes verwendet werden (Stand 01.05.2025):\r\n - **ICD**: 72506001 - Implantable defibrillator, device (physical object)\r\n - **CRT**: 704708004 - Cardiac resynchronization therapy implantable pacemaker (physical object)\r\n - **ICD+CRT**: 704707009 - Cardiac resynchronization therapy implantable defibrillator (physical object)\r\n - **Herzschrittmacher ohne genauere Bezeichnung**: 72506001 - Implantable defibrillator, device (physical object)\r\n - **LVAD**: 360066001 - Left ventricular assist device (physical object)\r\n - **RVAD**: 360065002 - Right ventricular assist device (physical object)\r\n - **BiVAD**: 360057000 - Biventricular assist device (physical object)",
      "mustSupport": true
    }, {
      "id": "Device.patient",
      "min": 1,
      "path": "Device.patient",
      "mustSupport": true
    } ]
  },
  "contact": [ {
    "telecom": [ {
      "value": "https://www.medizininformatik-initiative.de",
      "system": "url"
    } ]
  } ],
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Device"
}