    http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6041.html
{
  "description": "Transitive closure of CID 6041 MammographyImageQualityFinding",
  "compose": {
    "include": [ {
      "system": "http://dicom.nema.org/resources/ontology/DCM",
      "concept": [ {
        "code": "111182",
        "display": "View and Laterality Marker is partially obscured"
      }, {
        "code": "111183",
        "display": "View and Laterality Marker is incorrect"
      }, {
        "code": "111184",
        "display": "View and Laterality Marker is off image"
      }, {
        "code": "111185",
        "display": "Flash is not near edge of film"
      }, {
        "code": "111186",
        "display": "Flash is illegible, does not fit, or is lopsided"
      }, {
        "code": "111187",
        "display": "Flash doesn't include patient name and additional patient id"
      }, {
        "code": "111220",
        "display": "Other failure"
      }, {
        "code": "111188",
        "display": "Flash doesn't include date of examination"
      }, {
        "code": "111221",
        "display": "Unknown failure"
      }, {
        "code": "111189",
        "display": "Flash doesn't include facility name and location"
      }, {
        "code": "111200",
        "display": "MLO Evidence of motion blur"
      }, {
        "code": "111180",
        "display": "View and Laterality Marker is not near the axilla"
      }, {
        "code": "111181",
        "display": "View and Laterality Marker overlaps breast tissue"
      }, {
        "code": "111209",
        "display": "Positioning"
      }, {
        "code": "111201",
        "display": "MLO Inframammary fold is not open"
      }, {
        "code": "111202",
        "display": "CC Not all medial tissue visualized"
      }, {
        "code": "111203",
        "display": "CC Nipple not centered on image"
      }, {
        "code": "111204",
        "display": "CC Posterior nipple line does not measure within 1 cm of MLO"
      }, {
        "code": "111205",
        "display": "Nipple not in profile"
      }, {
        "code": "111206",
        "display": "Insufficient implant displacement incorrect"
      }, {
        "code": "111208",
        "display": "Grid artifact(s)"
      }, {
        "code": "111193",
        "display": "Date sticker is missing"
      }, {
        "code": "111194",
        "display": "Technical factors missing"
      }, {
        "code": "111195",
        "display": "Collimation too close to breast"
      }, {
        "code": "111196",
        "display": "Inadequate compression"
      }, {
        "code": "111197",
        "display": "MLO Insufficient pectoral muscle"
      }, {
        "code": "111198",
        "display": "MLO No fat is visualized posterior to fibroglandular tissues"
      }, {
        "code": "111177",
        "display": "View and Laterality Marker is missing"
      }, {
        "code": "111199",
        "display": "MLO Poor separation of deep and superficial breast tissues"
      }, {
        "code": "111210",
        "display": "Motion blur"
      }, {
        "code": "111178",
        "display": "View and Laterality Marker does not have both view and laterality"
      }, {
        "code": "111211",
        "display": "Under exposed"
      }, {
        "code": "111190",
        "display": "Flash doesn't include technologist identification"
      }, {
        "code": "111191",
        "display": "Flash doesn't include cassette/screen/detector identification"
      }, {
        "code": "111192",
        "display": "Flash doesn't include mammography unit identification"
      }, {
        "code": "111179",
        "display": "View and Laterality Marker does not have approved codes"
      }, {
        "code": "111212",
        "display": "Over exposed"
      }, {
        "code": "111213",
        "display": "No image"
      }, {
        "code": "111214",
        "display": "Detector artifact(s)"
      }, {
        "code": "111215",
        "display": "Artifact(s) other than grid or detector artifact"
      }, {
        "code": "111216",
        "display": "Mechanical failure"
      }, {
        "code": "111217",
        "display": "Electrical failure"
      }, {
        "code": "111218",
        "display": "Software failure"
      }, {
        "code": "111219",
        "display": "Inappropriate image processing"
      } ]
    } ]
  },
  "_filename": "ValueSet-dicom-cid-6041-MammographyImageQualityFinding.json",
  "package_name": "fhir.dicom",
  "date": "2024-01-20",
  "publisher": "NEMA MITA DICOM",
  "name": "MammographyImageQualityFinding",
  "copyright": "© 2024 NEMA",
  "type": null,
  "experimental": "false",
  "resourceType": "ValueSet",
  "title": null,
  "package_version": "2024.1.20240120",
  "status": "active",
  "id": "9820c25c-2324-4f81-88e4-46ae13199731",
  "kind": null,
  "url": "http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6041.html",
  "identifier": [ {
    "value": "urn:oid:1.2.840.10008.6.1.371",
    "system": "urn:ietf:rfc:3986"
  } ],
  "version": "2024.1.20240120"
}