"description": "Identifier-Profil für die Abbildung eines Institutionskennzeichens (IKNR)",
"_filename": "Profile-identifier-iknr.json",
"package_name": "de.basisprofil.r4",
"date": "2021-02-17",
"derivation": "constraint",
"publisher": "HL7 Deutschland e.V. (Technisches Komitee FHIR)",
"fhirVersion": "4.0.1",
"name": "IdentifierIknr",
"abstract": false,
"copyright": "HL7 Deutschland e.V.",
"type": "Identifier",
"experimental": null,
"resourceType": "StructureDefinition",
"title": "Identifier-Profil für die Abbildung eines Institutionskennzeichens (IKNR)",
"package_version": "1.2.0-alpha2",
"status": "active",
"id": "7b7b2aa4-e15b-484f-ae36-ac86ba79ec2e",
"kind": "complex-type",
"url": "http://fhir.de/StructureDefinition/identifier-iknr",
"version": "1.0.0",
"differential": {
"element": [ {
"id": "Identifier.use",
"path": "Identifier.use",
"fixedCode": "official"
}, {
"id": "Identifier.type",
"path": "Identifier.type",
"patternCodeableConcept": {
"coding": [ {
"code": "XX",
"system": "http://terminology.hl7.org/CodeSystem/v2-0203"
} ]
}
}, {
"id": "Identifier.system",
"min": 1,
"path": "Identifier.system",
"fixedUri": "http://fhir.de/sid/arge-ik/iknr"
}, {
"id": "Identifier.value",
"min": 1,
"path": "Identifier.value",
"constraint": [ {
"key": "ik-1",
"human": "Eine IK muss 8- (ohne Prüfziffer) oder 9-stellig (mit Prüfziffer) sein",
"source": "http://fhir.de/StructureDefinition/identifier-iknr",
"severity": "warning",
"expression": "matches('[0-9]{8,9}')"
} ]
} ]
},
"contact": [ {
"telecom": [ {
"value": "http://hl7.de/technische-komitees/fhir/",
"system": "other"
} ]
} ],
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/Identifier"
}