PackagesCanonicalsLogsProblems
    Packages
    xtehr.eu.ehds.models@1.0.0
    http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUseObligations
{
  "description": "Obligations for the logical model for device use.",
  "_filename": "StructureDefinition-EHDSDeviceUseObligations.json",
  "package_name": "xtehr.eu.ehds.models",
  "date": "2026-04-13T14:09:30+02:00",
  "derivation": "constraint",
  "publisher": "Xt-EHR",
  "fhirVersion": "5.0.0",
  "name": "EHDSDeviceUseObligations",
  "mapping": [ {
    "uri": "http://hl7.org/v3",
    "name": "RIM Mapping",
    "identity": "rim"
  } ],
  "abstract": false,
  "type": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUse",
  "experimental": null,
  "resourceType": "StructureDefinition",
  "title": "Device use obligations",
  "package_version": "1.0.0",
  "snapshot": {
    "element": [ {
      "path": "EHDSDeviceUse",
      "min": 0,
      "definition": "Model for information about the use of a device in the care of patient.",
      "isModifier": false,
      "short": "Device use model",
      "mapping": [ {
        "map": "n/a",
        "identity": "rim"
      } ],
      "max": "*",
      "id": "EHDSDeviceUse",
      "base": {
        "max": "*",
        "min": 0,
        "path": "Base"
      }
    }, {
      "id": "EHDSDeviceUse.header",
      "max": "1",
      "min": 1,
      "base": {
        "max": "1",
        "min": 1,
        "path": "EHDSDataSet.header"
      },
      "path": "EHDSDeviceUse.header",
      "type": [ {
        "code": "Base"
      } ],
      "short": "Basic metadata for this information",
      "definition": "Basic metadata for this information"
    }, {
      "path": "EHDSDeviceUse.header.subject",
      "min": 1,
      "definition": "Patient/subject information",
      "short": "Patient/subject information",
      "type": [ {
        "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSPatient"
      } ],
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHALL:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        }, {
          "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
          "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUseObligations|1.0.0"
        } ]
      } ],
      "max": "1",
      "id": "EHDSDeviceUse.header.subject",
      "base": {
        "max": "1",
        "min": 1,
        "path": "EHDSDataSet.header.subject"
      }
    }, {
      "id": "EHDSDeviceUse.header.identifier",
      "max": "*",
      "min": 0,
      "base": {
        "max": "*",
        "min": 0,
        "path": "EHDSDataSet.header.identifier"
      },
      "path": "EHDSDeviceUse.header.identifier",
      "type": [ {
        "code": "Identifier"
      } ],
      "short": "Business identifier for the object, unique within its system. Supporting disambiguation between different contexts (systems/countries).",
      "definition": "Business identifier for the object, unique within its system. Supporting disambiguation between different contexts (systems/countries)."
    }, {
      "id": "EHDSDeviceUse.header.author[x]",
      "max": "*",
      "min": 0,
      "base": {
        "max": "*",
        "min": 0,
        "path": "EHDSDataSet.header.author[x]"
      },
      "path": "EHDSDeviceUse.header.author[x]",
      "type": [ {
        "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSHealthProfessional"
      }, {
        "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSOrganisation"
      }, {
        "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDevice"
      } ],
      "short": "The author of the device usage statement.",
      "definition": "The author of the device usage statement."
    }, {
      "id": "EHDSDeviceUse.header.date",
      "max": "1",
      "min": 0,
      "base": {
        "max": "1",
        "min": 0,
        "path": "EHDSDataSet.header.date"
      },
      "path": "EHDSDeviceUse.header.date",
      "type": [ {
        "code": "dateTime"
      } ],
      "short": "Date and optionally time of authoring/issuing",
      "definition": "Date and optionally time of authoring/issuing"
    }, {
      "path": "EHDSDeviceUse.header.status",
      "min": 1,
      "definition": "Current status of the device usage (e.g. active, completed, etc).",
      "short": "Current status of the device usage (e.g. active, completed, etc).",
      "type": [ {
        "code": "CodeableConcept"
      } ],
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHALL:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        }, {
          "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
          "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUseObligations|1.0.0"
        } ]
      } ],
      "binding": {
        "strength": "preferred",
        "description": "HL7 Device Use Statement Status or HL7 Device Usage Status"
      },
      "max": "1",
      "id": "EHDSDeviceUse.header.status",
      "base": {
        "max": "1",
        "min": 1,
        "path": "EHDSDataSet.header.status"
      }
    }, {
      "id": "EHDSDeviceUse.header.source",
      "max": "1",
      "min": 0,
      "base": {
        "max": "1",
        "min": 0,
        "path": "EHDSDataSet.header.source"
      },
      "path": "EHDSDeviceUse.header.source",
      "type": [ {
        "code": "CodeableConcept"
      } ],
      "short": "Source of information (e.g. patient, patient's proxy). Used in case the patient has authored the information or the author has submitted patient-stated information.",
      "definition": "Source of information (e.g. patient, patient's proxy). Used in case the patient has authored the information or the author has submitted patient-stated information."
    }, {
      "path": "EHDSDeviceUse.header.language",
      "min": 0,
      "definition": "Language in which the resource is written. Language is expressed by the IETF language tag.",
      "short": "Language in which the resource is written. Language is expressed by the IETF language tag.",
      "type": [ {
        "code": "CodeableConcept"
      } ],
      "binding": {
        "strength": "preferred",
        "description": "BCP 47"
      },
      "max": "1",
      "id": "EHDSDeviceUse.header.language",
      "base": {
        "max": "1",
        "min": 0,
        "path": "EHDSDataSet.header.language"
      }
    }, {
      "path": "EHDSDeviceUse.periodOfUse",
      "requirements": "eHN PS Guideline, ISO IPS.",
      "min": 0,
      "definition": "The period of time during which the device was implanted in the patient or the external device was in use.",
      "short": "The period of time during which the device was implanted in the patient or the external device was in use.",
      "type": [ {
        "code": "Period"
      } ],
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHOULD:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        }, {
          "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
          "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUseObligations|1.0.0"
        } ]
      } ],
      "max": "1",
      "id": "EHDSDeviceUse.periodOfUse",
      "base": {
        "max": "1",
        "min": 0,
        "path": "EHDSDeviceUse.periodOfUse"
      }
    }, {
      "path": "EHDSDeviceUse.device[x]",
      "requirements": "eHN PS Guideline, ISO IPS.",
      "min": 1,
      "definition": "The details of the device used.",
      "short": "The details of the device used.",
      "type": [ {
        "code": "CodeableConcept"
      }, {
        "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDevice"
      } ],
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHALL:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        }, {
          "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
          "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUseObligations|1.0.0"
        } ]
      } ],
      "max": "1",
      "id": "EHDSDeviceUse.device[x]",
      "base": {
        "max": "1",
        "min": 1,
        "path": "EHDSDeviceUse.device[x]"
      }
    }, {
      "path": "EHDSDeviceUse.bodySite",
      "requirements": "eHN PS Guideline, ISO IPS.",
      "min": 0,
      "definition": "Anatomical location of the device. May include laterality.",
      "short": "Anatomical location of the device. May include laterality.",
      "type": [ {
        "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSBodyStructure"
      } ],
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHOULD:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        }, {
          "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
          "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUseObligations|1.0.0"
        } ]
      } ],
      "max": "1",
      "id": "EHDSDeviceUse.bodySite",
      "base": {
        "max": "1",
        "min": 0,
        "path": "EHDSDeviceUse.bodySite"
      }
    }, {
      "path": "EHDSDeviceUse.reason[x]",
      "requirements": "eHN PS Guideline, ISO IPS.",
      "min": 0,
      "definition": "Reason or justification for the use of the device.",
      "short": "Reason or justification for the use of the device.",
      "type": [ {
        "code": "CodeableConcept"
      }, {
        "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSCondition"
      }, {
        "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSObservation"
      }, {
        "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSProcedure"
      } ],
      "max": "*",
      "id": "EHDSDeviceUse.reason[x]",
      "base": {
        "max": "*",
        "min": 0,
        "path": "EHDSDeviceUse.reason[x]"
      }
    }, {
      "path": "EHDSDeviceUse.note",
      "min": 0,
      "definition": "Note about the device statement that were not represented at all or sufficiently in one of the attributes provided in a class. These may include for example a comment, an instruction, or a note associated with the statement.",
      "short": "Note about the device statement that were not represented at all or sufficiently in one of the attributes provided in a class. These may include for example a comment, an instruction, or a note associated with the statement.",
      "type": [ {
        "code": "string"
      } ],
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHOULD:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        }, {
          "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
          "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUseObligations|1.0.0"
        } ]
      } ],
      "max": "1",
      "id": "EHDSDeviceUse.note",
      "base": {
        "max": "1",
        "min": 0,
        "path": "EHDSDeviceUse.note"
      }
    } ],
    "extension": [ {
      "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
      "valueString": "1.0.0"
    } ]
  },
  "status": "active",
  "language": "en",
  "id": "3daa6201-53fe-4ed3-bd13-429acbc18f93",
  "kind": "logical",
  "url": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUseObligations",
  "version": "1.0.0",
  "differential": {
    "element": [ {
      "id": "EHDSDeviceUse",
      "path": "EHDSDeviceUse"
    }, {
      "id": "EHDSDeviceUse.header.subject",
      "path": "EHDSDeviceUse.header.subject",
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHALL:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        } ]
      } ]
    }, {
      "id": "EHDSDeviceUse.header.status",
      "path": "EHDSDeviceUse.header.status",
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHALL:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        } ]
      } ]
    }, {
      "id": "EHDSDeviceUse.periodOfUse",
      "path": "EHDSDeviceUse.periodOfUse",
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHOULD:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        } ]
      } ]
    }, {
      "id": "EHDSDeviceUse.device[x]",
      "path": "EHDSDeviceUse.device[x]",
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHALL:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        } ]
      } ]
    }, {
      "id": "EHDSDeviceUse.bodySite",
      "path": "EHDSDeviceUse.bodySite",
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHOULD:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        } ]
      } ]
    }, {
      "id": "EHDSDeviceUse.note",
      "path": "EHDSDeviceUse.note",
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/obligation",
        "extension": [ {
          "url": "code",
          "valueCode": "SHOULD:able-to-populate"
        }, {
          "url": "actor",
          "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
        } ]
      } ]
    } ]
  },
  "contact": [ {
    "name": "Xt-EHR",
    "telecom": [ {
      "value": "http://www.xt-ehr.eu/",
      "system": "url"
    } ]
  } ],
  "baseDefinition": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDeviceUse"
}