PackagesCanonicalsLogsProblems
    Packages
    PGO.02@1.02.1
    http://nictiz.nl/fhir/StructureDefinition/zib-BodyTemperature
description: 'This profile is derived from the HL7 Vital Signs profile for Body temperature in order to add mappings from the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or ZIB) BodyTemperature v3.1, release 2017, and to provide extensions for missing concepts.'
package_name: PGO.02
derivation: constraint
name: Zib BodyTemperature
type: Observation
elements:
  effective:
    short: TemperatureDateTime
    choices: []
    index: 1
  valueQuantity: {short: TemperatureValue recorded with UCUM, index: 2}
  comment: {short: Comment, index: 3}
  method: {short: TemperatureType, index: 4}
  device:
    type: Reference
    refers: ['http://nictiz.nl/fhir/StructureDefinition/zib-MedicalDeviceProduct']
    index: 5
package_version: 1.02.1
class: profile
kind: resource
url: http://nictiz.nl/fhir/StructureDefinition/zib-BodyTemperature
base: http://hl7.org/fhir/StructureDefinition/bodytemp
version: 2.0.1
required: [valueQuantity]