description: A point in time collection of post-acute care observations for a patient. This profile is used for exchanging a set of observation data collected through the use of a structured resource (e.g. assessment tool, instrument, or screen) with multiple questions. The specific questions within the structured tool are captured as child [observations](StructureDefinition-pfe-observation.html). package_name: hl7.fhir.us.pacio derivation: constraint name: PFECollection type: Observation elements: category: array: true min: 2 index: 4 slicing: slices: functioning: match: {} schema: mustSupport: true pattern: type: CodeableConcept value: coding: - {code: functioning, system: 'http://hl7.org/fhir/us/pacio-pfe/CodeSystem/pfe-functioning-cs', display: Functioning} _required: true index: 5 min: 1 max: 1 PFEDomain: match: {} schema: binding: {strength: required, valueSet: 'http://hl7.org/fhir/us/pacio-pfe/ValueSet/pfe-category-vs'} mustSupport: true array: true index: 6 min: 0 hasMember: type: Reference short: Each post-acute care observation in the collection. May also be another collection to support nested sections. refers: ['http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/pfe-observation'] index: 15 derivedFrom: type: Reference short: Should point back to the QuestionnaireResponse that this resource is derived from. refers: ['http://hl7.org/fhir/us/core/StructureDefinition/us-core-questionnaireresponse'] index: 16 value: short: If used, should use the CodeableConcept datatype whenever possible to provide a suitable code to define the concept for the observation data. When capturing a collection of related observations, typically this field is not used. If the outcome of an assessment includes one or more summary scores, leave this field unused and use the 'hasMember' field to point to one or more Observation resources with each of which has a score provided in the 'value' field. choices: [] index: 14 extension: index: 0 slicing: rules: open ordered: false discriminator: - {path: url, type: value} min: null slices: event-location: match: {url: null} schema: {short: An extension to indicate where the observation event occurred., type: Extension, mustSupport: true, url: 'http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/event-location', index: 1} min: 0 max: 1 device-use: match: {url: null} schema: {type: Extension, short: An extension to indicate a record of assistive device usage by a patient during an assessment., mustSupport: true, url: 'http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/device-patient-used', index: 2} min: 0 effectiveDateTime: {type: dateTime, short: 'Clinical relevant time for an assessment such as post-acute care observations performed with structured evaluation tools is the time the evaluation occurs, i.e., when the clinician obtains the answers entered in the tool. However, the only timing available may be when then tool is completed by the clinician. That timing is generally documented as a point in time (dateTime).', choiceOf: effective, index: 10} status: {short: 'Should have the value ''final'' when all the observatons are complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.', index: 3} effective: short: Clinical relevant time for an assessment such as post-acute care observations performed with structured evaluation tools is the time the evaluation occurs, i.e., when the clinician obtains the answers entered in the tool. However, the only timing available may be when then tool is completed by the clinician. That timing is generally documented as a point in time (dateTime). choices: [effectiveDateTime, effectivePeriod] index: 9 code: short: For a Post-Acute Care structured assessment resource such as an instrument or screen, use a LOINC code to identify the instrument/screen name or panel/section title to indicate the kind of assessment. binding: {strength: extensible, valueSet: 'http://hl7.org/fhir/us/pacio-pfe/ValueSet/pfe-loinc-snomed-vs'} index: 7 performer: type: Reference short: The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization. refers: ['http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization', 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner', 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole'] index: 12 effectivePeriod: {type: Period, short: 'Clinical relevant time for an assessment such as post-acute care observations performed with structured evaluation tools is the time the evaluation occurs, i.e., when the clinician obtains the answers entered in the tool. However, the only timing available may be when then tool is completed by the clinician. That timing is generally documented as a point in time (dateTime).', choiceOf: effective, index: 11} package_version: pfe-1.0.0-ballot extensions: event-location: {url: 'http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/event-location', min: 0, max: 1, short: An extension to indicate where the observation event occurred., type: Extension, mustSupport: true, index: 1} device-use: {url: 'http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/device-patient-used', min: 0, type: Extension, short: An extension to indicate a record of assistive device usage by a patient during an assessment., mustSupport: true, index: 2} class: profile kind: resource url: http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/pfe-collection base: http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-survey version: 1.0.0-ballot required: [effectiveDateTime, effectivePeriod, effective, performer]