{
"description": "Code system for codes that are defined in DICOM but for which no matching code system is available in FHIR.",
"_filename": "CodeSystem-codesystem-missing-dicom-terminology.json",
"package_name": "hl7.fhir.cz.img",
"date": "2026-08-05T13:47:14+02:00",
"publisher": "HL7 Czech Republic",
"jurisdiction": [ {
"coding": [ {
"code": "CZ",
"system": "urn:iso:std:iso:3166",
"display": "Czechia"
} ]
} ],
"content": "fragment",
"name": "MissingDicomTerminology",
"type": null,
"experimental": "false",
"resourceType": "CodeSystem",
"title": "Missing DICOM Terminology",
"package_version": "1.0.0",
"status": "draft",
"hierarchyMeaning": "is-a",
"id": "11d9e48e-278d-4222-9e1c-4629b74b79f9",
"kind": null,
"url": "http://hl7.eu/fhir/imaging/CodeSystem/codesystem-missing-dicom-terminology",
"concept": [ {
"code": "elements",
"concept": [ {
"code": "00080016",
"display": "SOP Class UID",
"definition": "Uniquely identifies the SOP Class."
}, {
"code": "00080018",
"display": "SOP Instance UID",
"definition": "Uniquely identifies the SOP Instance."
}, {
"code": "00080060",
"display": "Modality",
"definition": "Type of device, process or method that originally acquired or produced the data used to create the Instances in this Series."
}, {
"code": "00083010",
"display": "Irradiation Event UID",
"definition": "Irradiation Event UID"
}, {
"code": "00181000",
"display": "Device Serial Number",
"definition": "Device Serial Number"
}, {
"code": "00181002",
"display": "Device UID",
"definition": "Unique identifier of the equipment."
}, {
"code": "00181008",
"display": "Manufacturer Device Class UID",
"definition": "Manufacturer Device Class UID"
}, {
"code": "0020000D",
"display": "Study Instance UID",
"definition": "Unique identifier for the Study."
}, {
"code": "0020000E",
"display": "Series Instance UID",
"definition": "Unique identifier of the Series."
}, {
"code": "00080050",
"display": "Accession Number",
"definition": "A departmental Information System generated number that identifies the Imaging Service Request."
}, {
"code": "0040A171",
"display": "Observation UID",
"definition": "Unique identifier for the observation Content Item (and its subsidiary Content Items, if any). The UID represents the semantic content of the observation; an encoding of the same observation with the same context into another representation (e.g., a CDA Entry) may use the same UID."
}, {
"code": "00400554",
"display": "Specimen UID",
"definition": "Unique identifier for the Specimen."
}, {
"code": "00620021",
"display": "Tracking UID",
"definition": "A unique identifier used for tracking a finding or feature, potentially across multiple reporting objects, over time."
} ],
"display": "DICOM Elements",
"definition": "DICOM Element definitions"
} ],
"caseSensitive": true,
"version": "1.0.0",
"contact": [ {
"name": "HL7 Czech Republic",
"telecom": [ {
"value": "https://www.hl7.cz/",
"system": "url"
} ]
} ]
}