description: Arterial oxygen saturation, also referred to as saturation, is an indicator for the amount of oxygen bound to the hemoglobin in the red blood cells of the arteries. The measurement is usually carried out as a transcutaneous measurement with a blood oxygen monitor or pulse oximeter. The saturation level is expressed as a percentage and should be over 95% in healthy people. \r\n#### Purpose\r\nMeasuring and monitoring oxygen saturation is done to monitor the oxygenation, or the amount of bound oxygen in the arterial blood. package_name: healthdata.be.r4.cbb derivation: specialization name: HdBeO2Saturation abstract: true type: https://fhir.healthdata.be/StructureDefinition/LogicalModel/O2Saturation elements: SpO2value: short: SpO2Value _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-NL} - url: content valueMarkdown: "Het element bevat de waarde van de indirect, perifeer gemeten O2-saturatie.\r\nDe O2-saturatie geeft in % de mate aan waarin de hemoglobine in het bloed verzadigd is met zuurstof, de ratio van oxy-hemoglobine en hemoglobine.\r\nDe meting wordt uitgevoerd op plaatsen waar de huid voldoende licht doorlaat, zoals een vinger, teen of oorlel." type: Quantity _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-NL} - {url: content, valueMarkdown: SpO2Waarde} index: 0 O2saturationDateTime: short: O2SaturationDateTime _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-NL} - {url: content, valueMarkdown: Het moment van waarneming van de SpO2.} type: dateTime _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-NL} - {url: content, valueMarkdown: O2SaturatieDatumTijd} index: 1 Comment: short: Comment _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-NL} - {url: content, valueMarkdown: Toelichting op de meting van de saturatie.} type: string _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-NL} - {url: content, valueMarkdown: Toelichting} index: 2 ExtraOxygenAdministration: short: ExtraOxygenAdministration _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-NL} - {url: content, valueMarkdown: Indicatie of de meting gedaan werd in een situatie waar sprake was van extra zuurstof toediening.} type: boolean _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-NL} - {url: content, valueMarkdown: ExtraZuurstofToediening} index: 3 package_version: 0.10.0-beta class: logical kind: logical url: https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-O2Saturation base: http://hl7.org/fhir/StructureDefinition/Element version: null required: [SpO2value, O2saturationDateTime]