PackagesCanonicalsLogsProblems
    Packages
    nictiz.fhir.nl.r4.zib2020@0.5.0-beta1
    http://nictiz.nl/fhir/StructureDefinition/zib-VisualFunction.VisualAid
{
  "description": "Sight is the ability to observe lit objects, with the goal of orienting yourself on objects and people in a lit environment. This pertains to observing the light stimuli, and not processing them in the brain.\\r\\nA sight disorder can lead to things including orientation problems.",
  "_filename": "zib-VisualFunction.VisualAid.json",
  "package_name": "nictiz.fhir.nl.r4.zib2020",
  "date": null,
  "derivation": "constraint",
  "publisher": "Nictiz",
  "fhirVersion": "4.0.1",
  "purpose": "This DeviceUseStatement resource represents the adaptations for the Dutch [zib ('Zorginformatiebouwsteen', i.e. Health and Care Information Model) VisualFunction v3.1 (2020)](https://zibs.nl/wiki/VisualFunction-v3.1(2020EN)) of [zib MedicalDevice v3.3.1 (2020)](https://zibs.nl/wiki/MedicalDevice-v3.3.1(2020EN)).",
  "name": "ZibVisualFunctionVisualAid",
  "mapping": [ {
    "uri": "https://zibs.nl/wiki/VisualFunction-v3.1(2020EN)",
    "name": "zib VisualFunction-v3.1(2020EN)",
    "identity": "zib-visualfunction-v3.1-2020EN"
  } ],
  "abstract": true,
  "copyright": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
  "type": "DeviceUseStatement",
  "experimental": null,
  "resourceType": "StructureDefinition",
  "title": "zib VisualFunction.VisualAid",
  "package_version": "0.5.0-beta1",
  "status": "draft",
  "id": "f394479c-9661-49f4-84a4-74b898db97a3",
  "kind": "resource",
  "url": "http://nictiz.nl/fhir/StructureDefinition/zib-VisualFunction.VisualAid",
  "version": null,
  "differential": {
    "element": [ {
      "id": "DeviceUseStatement",
      "path": "DeviceUseStatement",
      "comment": "This is a specialization of the [zib-MedicalDevice](http://nictiz.nl/fhir/StructureDefinition/zib-MedicalDevice) profile to represent VisualAid devices within the context of zib VisualFunction.",
      "definition": "The medical aids used to support the visual function."
    }, {
      "id": "DeviceUseStatement.device",
      "path": "DeviceUseStatement.device",
      "type": [ {
        "code": "Reference",
        "targetProfile": [ "http://hl7.org/fhir/StructureDefinition/Device", "http://nictiz.nl/fhir/StructureDefinition/zib-VisualFunction.VisualAid.Product" ]
      } ]
    }, {
      "id": "DeviceUseStatement.reasonReference:zibMedicalDeviceReference",
      "max": "0",
      "path": "DeviceUseStatement.reasonReference",
      "sliceName": "zibMedicalDeviceReference"
    }, {
      "id": "DeviceUseStatement.reasonReference:visualFunction",
      "path": "DeviceUseStatement.reasonReference",
      "type": [ {
        "code": "Reference",
        "targetProfile": [ "http://nictiz.nl/fhir/StructureDefinition/zib-VisualFunction" ]
      } ],
      "alias": [ "FunctieZien" ],
      "short": "VisualFunction",
      "comment": "Please note that on a functional level, zib VisualFunction references zib MedicalDevice, but in FHIR this direction is reversed.",
      "mapping": [ {
        "map": "NL-CM:4.16.4",
        "comment": "Reversed reference for zib VisualFunction.VisualAid",
        "identity": "zib-visualfunction-v3.1-2020EN"
      } ],
      "sliceName": "visualFunction"
    } ]
  },
  "contact": [ {
    "name": "Nictiz",
    "telecom": [ {
      "use": "work",
      "value": "https://www.nictiz.nl",
      "system": "url"
    } ]
  } ],
  "baseDefinition": "http://nictiz.nl/fhir/StructureDefinition/zib-MedicalDevice"
}