PackagesCanonicalsLogsProblems
    Packages
    fhir.r4.ukcore.stu3.currentbuild@0.28.0-pre-release
    https://fhir.hl7.org.uk/StructureDefinition/UKCore-DiagnosticReport
description: This profile defines the UK constraints and extensions on the International FHIR resource [DiagnosticReport](https://hl7.org/fhir/R4/DiagnosticReport.html).
package_name: fhir.r4.ukcore.stu3.currentbuild
derivation: constraint
name: UKCoreDiagnosticReport
type: DiagnosticReport
elements:
  category: {short: 'A code that classifies the clinical discipline, department or diagnostic service that created the report.', mustSupport: true, index: 1}
  conclusionCode: {index: 9}
  encounter: {short: Health care event when test ordered., mustSupport: true, index: 4}
  resultsInterpreter:
    extensions:
      deviceReference: {url: 'https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-DeviceReference', type: Extension, short: A reference to a Device which interprets / performs the results of the DiagnosticReport., isModifier: false, index: 7}
    elements:
      extension:
        type: Extension
        short: A reference to a Device which interprets / performs the results of the DiagnosticReport.
        isModifier: false
        url: https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-DeviceReference
        index: 7
        slicing:
          slices:
            deviceReference:
              match: {}
              schema: {type: Extension, short: A reference to a Device which interprets / performs the results of the DiagnosticReport., isModifier: false, url: 'https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-DeviceReference', index: 7}
  status: {short: The status of the diagnostic report., mustSupport: true, index: 0}
  result: {short: Observations that are part of this diagnostic report., mustSupport: true, index: 8}
  code:
    short: A code or name that describes this diagnostic report.
    binding: {strength: preferred, valueSet: 'https://fhir.hl7.org.uk/ValueSet/UKCore-ReportCode'}
    mustSupport: true
    index: 2
  issued: {short: Clinically relevant time / time-period for report., mustSupport: true, index: 5}
  subject: {short: 'The subject of the report - usually, but not always, the patient.', mustSupport: true, index: 3}
  performer:
    extensions:
      deviceReference: {url: 'https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-DeviceReference', max: 1, type: Extension, short: A reference to a Device which interprets / performs the results of the DiagnosticReport., isModifier: false, index: 6}
    elements:
      extension:
        type: Extension
        short: A reference to a Device which interprets / performs the results of the DiagnosticReport.
        isModifier: false
        url: https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-DeviceReference
        index: 6
        slicing:
          slices:
            deviceReference:
              match: {}
              schema: {type: Extension, short: A reference to a Device which interprets / performs the results of the DiagnosticReport., isModifier: false, url: 'https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-DeviceReference', index: 6}
              max: 1
package_version: 0.28.0-pre-release
class: profile
kind: resource
url: https://fhir.hl7.org.uk/StructureDefinition/UKCore-DiagnosticReport
base: http://hl7.org/fhir/StructureDefinition/DiagnosticReport
version: 3.0.0