PackagesCanonicalsLogsProblems
    Packages
    uk.nhsdigital.stu3.test@0.0.2-prerelease
    https://fhir.nhs.uk/STU3/StructureDefinition/ITK-Device-1
{
  "description": "This resource is primarily used for recording which device performed an action and can also be used to track device location. It is also used for prescribing and dispensing devices for patient use. If the device is implanted in a patient, then the patient element will be present, and there would be no location.",
  "_filename": "ITK-Device-1.json",
  "package_name": "uk.nhsdigital.stu3.test",
  "date": "2017-12-13",
  "derivation": "constraint",
  "meta": {
    "tag": [ {
      "code": "10"
    } ],
    "lastUpdated": "2018-05-16T23:54:04.17+01:00"
  },
  "publisher": "NHS Digital",
  "fhirVersion": "3.0.1",
  "purpose": "A device could be the author of a document in this message.",
  "name": "ITK-Device-1",
  "abstract": false,
  "copyright": "Copyright ©2017 NHS Digital",
  "type": "Device",
  "experimental": null,
  "resourceType": "StructureDefinition",
  "title": "ITK Device",
  "package_version": "0.0.2-prerelease",
  "extension": [ {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
    "valueCode": "oo"
  } ],
  "status": "draft",
  "id": "eac98d2c-d89e-4209-af76-6daa997b09a3",
  "kind": "resource",
  "url": "https://fhir.nhs.uk/STU3/StructureDefinition/ITK-Device-1",
  "version": "1.0.0",
  "differential": {
    "element": [ {
      "id": "Device.identifier.type.coding.system",
      "min": 1,
      "path": "Device.identifier.type.coding.system"
    }, {
      "id": "Device.identifier.type.coding.code",
      "min": 1,
      "path": "Device.identifier.type.coding.code"
    }, {
      "id": "Device.identifier.type.coding.display",
      "min": 1,
      "path": "Device.identifier.type.coding.display",
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/elementdefinition-translatable",
        "valueBoolean": true
      } ]
    }, {
      "id": "Device.identifier.value",
      "min": 1,
      "path": "Device.identifier.value"
    }, {
      "id": "Device.identifier.assigner",
      "path": "Device.identifier.assigner",
      "type": [ {
        "code": "Reference",
        "targetProfile": "https://fhir.hl7.org.uk/STU3/StructureDefinition/CareConnect-Organization-1"
      } ]
    }, {
      "id": "Device.identifier.assigner.reference",
      "min": 1,
      "path": "Device.identifier.assigner.reference"
    }, {
      "id": "Device.type",
      "min": 1,
      "path": "Device.type",
      "binding": {
        "strength": "preferred",
        "extension": [ {
          "url": "http://hl7.org/fhir/StructureDefinition/elementdefinition-bindingName",
          "valueString": "DeviceKind"
        } ],
        "description": "Defines the nature of the device and also the kind of functionality/services/behavior that may be expected from it.",
        "valueSetReference": {
          "reference": "https://fhir.nhs.uk/STU3/ValueSet/DeviceType-1"
        }
      }
    }, {
      "id": "Device.type.coding.system",
      "min": 1,
      "path": "Device.type.coding.system"
    }, {
      "id": "Device.type.coding.code",
      "min": 1,
      "path": "Device.type.coding.code"
    }, {
      "id": "Device.type.coding.display",
      "min": 1,
      "path": "Device.type.coding.display",
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/elementdefinition-translatable",
        "valueBoolean": true
      } ]
    }, {
      "id": "Device.patient",
      "path": "Device.patient",
      "type": [ {
        "code": "Reference",
        "targetProfile": "https://fhir.hl7.org.uk/STU3/StructureDefinition/CareConnect-Patient-1"
      } ]
    }, {
      "id": "Device.patient.reference",
      "min": 1,
      "path": "Device.patient.reference"
    }, {
      "id": "Device.owner",
      "path": "Device.owner",
      "type": [ {
        "code": "Reference",
        "targetProfile": "https://fhir.hl7.org.uk/STU3/StructureDefinition/CareConnect-Organization-1"
      } ]
    }, {
      "id": "Device.owner.reference",
      "min": 1,
      "path": "Device.owner.reference"
    }, {
      "id": "Device.contact.system",
      "min": 1,
      "path": "Device.contact.system"
    }, {
      "id": "Device.contact.value",
      "min": 1,
      "path": "Device.contact.value"
    }, {
      "id": "Device.location",
      "path": "Device.location",
      "type": [ {
        "code": "Reference",
        "targetProfile": "https://fhir.hl7.org.uk/STU3/StructureDefinition/CareConnect-Location-1"
      } ]
    }, {
      "id": "Device.location.reference",
      "min": 1,
      "path": "Device.location.reference"
    }, {
      "id": "Device.note",
      "max": "0",
      "path": "Device.note"
    }, {
      "id": "Device.note.authorReference:authorReference",
      "path": "Device.note.authorReference",
      "type": [ {
        "code": "Reference",
        "targetProfile": "https://fhir.nhs.uk/STU3/StructureDefinition/CareConnect-ITK-Header-Practitioner-1"
      } ],
      "sliceName": "authorReference"
    }, {
      "id": "Device.note.authorReference:authorReference.reference",
      "min": 1,
      "path": "Device.note.authorReference.reference"
    }, {
      "id": "Device.safety.coding.system",
      "min": 1,
      "path": "Device.safety.coding.system"
    }, {
      "id": "Device.safety.coding.code",
      "min": 1,
      "path": "Device.safety.coding.code"
    }, {
      "id": "Device.safety.coding.display",
      "min": 1,
      "path": "Device.safety.coding.display",
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/elementdefinition-translatable",
        "valueBoolean": true
      } ]
    } ]
  },
  "contact": [ {
    "name": "Interoperability Team",
    "telecom": [ {
      "use": "work",
      "value": "interoperabilityteam@nhs.net",
      "system": "email"
    } ]
  } ],
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Device"
}