"description": "BpcServiceInputParameters",
"_filename": "StructureDefinition-BpcServiceInputParameters.json",
"package_name": "de.medizininformatikinitiative.use",
"date": "2024-12-11",
"derivation": "constraint",
"publisher": "MOLIT gGmbH",
"fhirVersion": "4.0.1",
"name": "BpcServiceInputParameters",
"abstract": false,
"type": "Parameters",
"experimental": null,
"resourceType": "StructureDefinition",
"title": "BpcServiceInputParameters",
"package_version": "case.omi-0.3.16",
"status": "active",
"id": "e94f27a4-7891-480e-a7b5-5fe3a7e172f0",
"kind": "resource",
"url": "http://omi.de/fhir/registry/StructureDefinition/BpcServiceInputParameters",
"version": "0.3.16",
"differential": {
"element": [ {
"id": "Parameters.parameter",
"min": 1,
"path": "Parameters.parameter"
}, {
"id": "Parameters.parameter:imagingStudy",
"max": "1",
"path": "Parameters.parameter",
"sliceName": "imagingStudy"
}, {
"id": "Parameters.parameter:imagingStudy.resource",
"path": "Parameters.parameter.resource",
"constraint": [ {
"key": "mii-imageType-localizer",
"human": "ImageType extension string must contain 'LOCALIZER', returns true if it does",
"source": "http://omi.de/fhir/registry/StructureDefinition/BpcServiceInputParameters",
"severity": "error",
"expression": "ImagingStudy.series.instance.extension('https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-instanz-details').extension('imageType').valueCodeableConcept.coding.where(system = 'https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/CodeSystem/mii-cs-bildgebung-instance-image-type' and code = 'LOCALIZER').exists()"
}, {
"key": "mii-instance-imageType-checker",
"human": "Returns true if there is at most one instance with an imageType that contains `LOCALIZER`",
"source": "http://omi.de/fhir/registry/StructureDefinition/BpcServiceInputParameters",
"severity": "error",
"expression": "ImagingStudy.series.instance.extension('https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-instanz-details').extension('imageType').valueCodeableConcept.coding.where(system = 'https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/CodeSystem/mii-cs-bildgebung-instance-image-type' and code = 'LOCALIZER').count() <= 1"
} ]
}, {
"id": "Parameters.parameter:image-binary",
"max": "1",
"min": 1,
"path": "Parameters.parameter",
"sliceName": "image-binary"
} ]
},
"baseDefinition": "http://omi.de/fhir/registry/StructureDefinition/omi-service-input-parameter"
}