"description": "Israel Core proposed constraints and extensions on the Observation Resource for use in Blood Pressure measurments.",
"_filename": "StructureDefinition-il-core-bp.json",
"package_name": "il.core.fhir.r4",
"date": "2025-03-27",
"derivation": "constraint",
"publisher": "Israel Core Team",
"fhirVersion": "4.0.1",
"name": "ILCoreBP",
"abstract": false,
"type": "Observation",
"experimental": null,
"resourceType": "StructureDefinition",
"title": "ILCore Blood Pressure Profile",
"package_version": "0.17.3",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode": "draft"
}, {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 0
} ],
"status": "active",
"id": "e2e2d977-b4c4-4211-870f-6c084eabc99f",
"kind": "resource",
"url": "http://fhir.health.gov.il/StructureDefinition/il-core-bp",
"version": "0.17.0",
"differential": {
"element": [ {
"id": "Observation",
"path": "Observation",
"short": "ILCore Blood Pressure Profile"
}, {
"id": "Observation.code",
"path": "Observation.code",
"definition": "Code specifying blood pressure measurement type",
"patternCodeableConcept": {
"coding": [ {
"code": "85354-9",
"system": "http://loinc.org"
} ]
}
}, {
"id": "Observation.value[x]",
"max": "0",
"path": "Observation.value[x]",
"comment": "Should be filled in the 'component' elements"
}, {
"id": "Observation.value[x]:valueQuantity",
"max": "0",
"path": "Observation.value[x]",
"type": [ {
"code": "Quantity"
} ],
"sliceName": "valueQuantity"
}, {
"id": "Observation.value[x]:valueCodeableConcept",
"max": "0",
"path": "Observation.value[x]",
"type": [ {
"code": "CodeableConcept"
} ],
"sliceName": "valueCodeableConcept"
}, {
"id": "Observation.referenceRange",
"max": "0",
"path": "Observation.referenceRange",
"comment": "Should be filled in the 'component' elements"
}, {
"id": "Observation.component",
"min": 2,
"path": "Observation.component",
"slicing": {
"rules": "open",
"ordered": false,
"discriminator": [ {
"path": "code.coding.system",
"type": "value"
}, {
"path": "code.coding.code",
"type": "value"
} ]
}
}, {
"id": "Observation.component:SystolicBP",
"max": "1",
"min": 1,
"path": "Observation.component",
"sliceName": "SystolicBP"
}, {
"id": "Observation.component:SystolicBP.code.coding",
"min": 1,
"path": "Observation.component.code.coding",
"slicing": {
"rules": "open",
"ordered": false,
"discriminator": [ {
"path": "system",
"type": "value"
}, {
"path": "code",
"type": "value"
} ]
}
}, {
"id": "Observation.component:SystolicBP.code.coding:SBPCode",
"max": "1",
"min": 1,
"path": "Observation.component.code.coding",
"sliceName": "SBPCode"
}, {
"id": "Observation.component:SystolicBP.code.coding:SBPCode.system",
"min": 1,
"path": "Observation.component.code.coding.system",
"fixedUri": "http://loinc.org",
"mustSupport": true
}, {
"id": "Observation.component:SystolicBP.code.coding:SBPCode.code",
"min": 1,
"path": "Observation.component.code.coding.code",
"fixedCode": "8480-6",
"mustSupport": true
}, {
"id": "Observation.component:SystolicBP.value[x]",
"path": "Observation.component.value[x]",
"type": [ {
"code": "Quantity"
} ]
}, {
"id": "Observation.component:SystolicBP.value[x]:valueQuantity",
"path": "Observation.component.value[x]",
"type": [ {
"code": "Quantity"
} ],
"sliceName": "valueQuantity"
}, {
"id": "Observation.component:SystolicBP.value[x]:valueQuantity.value",
"min": 1,
"path": "Observation.component.value[x].value",
"mustSupport": true
}, {
"id": "Observation.component:SystolicBP.value[x]:valueQuantity.unit",
"min": 1,
"path": "Observation.component.value[x].unit",
"mustSupport": true
}, {
"id": "Observation.component:SystolicBP.value[x]:valueQuantity.system",
"path": "Observation.component.value[x].system",
"fixedUri": "http://unitsofmeasure.org",
"mustSupport": true
}, {
"id": "Observation.component:SystolicBP.value[x]:valueQuantity.code",
"min": 1,
"path": "Observation.component.value[x].code",
"fixedCode": "mm[Hg]",
"mustSupport": true
}, {
"id": "Observation.component:SystolicBP.value[x]:valueCodeableConcept",
"max": "0",
"path": "Observation.component.value[x]",
"type": [ {
"code": "CodeableConcept"
} ],
"sliceName": "valueCodeableConcept"
}, {
"id": "Observation.component:DiastolicBP",
"max": "1",
"min": 1,
"path": "Observation.component",
"sliceName": "DiastolicBP"
}, {
"id": "Observation.component:DiastolicBP.code.coding",
"min": 1,
"path": "Observation.component.code.coding",
"slicing": {
"rules": "open",
"ordered": false,
"discriminator": [ {
"path": "system",
"type": "value"
}, {
"path": "code",
"type": "value"
} ]
}
}, {
"id": "Observation.component:DiastolicBP.code.coding:DBPCode",
"max": "1",
"min": 1,
"path": "Observation.component.code.coding",
"sliceName": "DBPCode"
}, {
"id": "Observation.component:DiastolicBP.code.coding:DBPCode.system",
"min": 1,
"path": "Observation.component.code.coding.system",
"fixedUri": "http://loinc.org",
"mustSupport": true
}, {
"id": "Observation.component:DiastolicBP.code.coding:DBPCode.code",
"min": 1,
"path": "Observation.component.code.coding.code",
"fixedCode": "8462-4",
"mustSupport": true
}, {
"id": "Observation.component:DiastolicBP.value[x]",
"path": "Observation.component.value[x]",
"type": [ {
"code": "Quantity"
} ]
}, {
"id": "Observation.component:DiastolicBP.value[x]:valueQuantity",
"path": "Observation.component.value[x]",
"type": [ {
"code": "Quantity"
} ],
"sliceName": "valueQuantity"
}, {
"id": "Observation.component:DiastolicBP.value[x]:valueQuantity.value",
"min": 1,
"path": "Observation.component.value[x].value",
"mustSupport": true
}, {
"id": "Observation.component:DiastolicBP.value[x]:valueQuantity.unit",
"min": 1,
"path": "Observation.component.value[x].unit",
"mustSupport": true
}, {
"id": "Observation.component:DiastolicBP.value[x]:valueQuantity.system",
"path": "Observation.component.value[x].system",
"fixedUri": "http://unitsofmeasure.org",
"mustSupport": true
}, {
"id": "Observation.component:DiastolicBP.value[x]:valueQuantity.code",
"min": 1,
"path": "Observation.component.value[x].code",
"fixedCode": "mm[Hg]",
"mustSupport": true
}, {
"id": "Observation.component:DiastolicBP.value[x]:valueCodeableConcept",
"max": "0",
"path": "Observation.component.value[x]",
"type": [ {
"code": "CodeableConcept"
} ],
"sliceName": "valueCodeableConcept"
} ]
},
"contact": [ {
"telecom": [ {
"value": "tal.primak@moh.gov.il",
"system": "email"
} ]
} ],
"baseDefinition": "http://fhir.health.gov.il/StructureDefinition/il-core-vital-signs"
}