{ "description": "Fachliches Modell zur Beschreibung der Informationen, die bei $close und $dispense in der MedicationDispense-Ressource für DiGAs übermittelt werden.", "_filename": "StructureDefinition-logMedDispenseDiGA.json", "package_name": "de.gematik.erezept-workflow.r4", "date": "2024-07-15", "derivation": "specialization", "publisher": null, "fhirVersion": "4.0.1", "name": "GEM_ERP_LOG_MedicationDispense_DiGA", "mapping": [ { "uri": "GEM_ERP_PR_MedicationDispense_DiGA", "name": "Mapping for MedicationDispense DiGA", "comment": "This mapping maps the logical units of the DiGA MedicationDispense to the profile", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "abstract": false, "type": "https://gematik.de/fhir/erp/StructureDefinition/logMedDispenseDiGA", "experimental": null, "resourceType": "StructureDefinition", "title": "Logical DiGA Medication Dispense", "package_version": "1.4.0", "status": "active", "id": "ddbd54d0-601d-4330-bcad-9c081f5c5bd5", "kind": "logical", "url": "https://gematik.de/fhir/erp/StructureDefinition/logMedDispenseDiGA", "version": "1.4", "differential": { "element": [ { "id": "logMedDispenseDiGA", "path": "logMedDispenseDiGA", "short": "Logical DiGA Medication Dispense", "mapping": [ { "map": "GEM_ERP_PR_MedicationDispense_DiGA", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Fachliches Modell zur Beschreibung der Informationen, die bei $close und $dispense in der MedicationDispense-Ressource für DiGAs übermittelt werden." }, { "id": "logMedDispenseDiGA.prescriptionId", "max": "1", "min": 1, "path": "logMedDispenseDiGA.prescriptionId", "type": [ { "code": "string" } ], "short": "ID des E-Rezepts", "mapping": [ { "map": "identifier[prescriptionID].value", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "ID des E-Rezepts" }, { "id": "logMedDispenseDiGA.status", "max": "1", "min": 1, "path": "logMedDispenseDiGA.status", "type": [ { "code": "code" } ], "short": "Status fixedValue: #completed", "mapping": [ { "map": "status", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Status fixedValue: #completed" }, { "id": "logMedDispenseDiGA.patientKVNR", "max": "1", "min": 1, "path": "logMedDispenseDiGA.patientKVNR", "type": [ { "code": "string" } ], "short": "KVNR des Patienten", "mapping": [ { "map": "subject.identifier.value", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "KVNR des Patienten" }, { "id": "logMedDispenseDiGA.angabeAbgebendeInstutition", "max": "1", "min": 1, "path": "logMedDispenseDiGA.angabeAbgebendeInstutition", "type": [ { "code": "Identifier" } ], "short": "Telematik-ID der abgebenden Institution", "mapping": [ { "map": "performer.actor.identifier.value", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Telematik-ID der abgebenden Institution" }, { "id": "logMedDispenseDiGA.freischaltCode", "max": "1", "min": 0, "path": "logMedDispenseDiGA.freischaltCode", "type": [ { "code": "string" } ], "short": "Freischaltcode für die DiGA", "mapping": [ { "map": "extension[redeemCode].valueString", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Optional, da die Kasse die Bereitstellung eines Freischaltcodes ablehnen kann." }, { "id": "logMedDispenseDiGA.deepLink", "max": "1", "min": 0, "path": "logMedDispenseDiGA.deepLink", "type": [ { "code": "string" } ], "short": "Universeller Deep Link, der vom DiGA Hersteller bereitgestellt wird", "mapping": [ { "map": "extension[deepLink].valueUrl", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Universeller Deep Link, der vom DiGA Hersteller bereitgestellt wird" }, { "id": "logMedDispenseDiGA.angabenZurDiGA", "max": "1", "min": 0, "path": "logMedDispenseDiGA.angabenZurDiGA", "type": [ { "code": "BackboneElement" } ], "short": "Angaben zur DiGA. Zwingend anzugeben, wenn ein Freischaltcode bereitgestellt wird.", "mapping": [ { "map": "medicationReference", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Angaben zur DiGA. Zwingend anzugeben, wenn ein Freischaltcode bereitgestellt wird." }, { "id": "logMedDispenseDiGA.angabenZurDiGA.name", "max": "1", "min": 1, "path": "logMedDispenseDiGA.angabenZurDiGA.name", "type": [ { "code": "string" } ], "short": "Name der DiGA-Verordnungseinheit", "mapping": [ { "map": "medicationReference.display", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Name der DiGA-Verordnungseinheit" }, { "id": "logMedDispenseDiGA.angabenZurDiGA.pzn", "max": "1", "min": 1, "path": "logMedDispenseDiGA.angabenZurDiGA.pzn", "type": [ { "code": "string" } ], "short": "Pharmazentralnummer als eindeutige Identifikationsnummer zu einer Verordnungseinheit einer digitalen Gesundheitsanwendung (PZN).", "mapping": [ { "map": "medicationReference.identifier.value", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Pharmazentralnummer als eindeutige Identifikationsnummer zu einer Verordnungseinheit einer digitalen Gesundheitsanwendung (PZN)." }, { "id": "logMedDispenseDiGA.angabenZurDiGA.dataAbsentReason", "max": "1", "min": 0, "path": "logMedDispenseDiGA.angabenZurDiGA.dataAbsentReason", "type": [ { "code": "code" } ], "short": "Wird angegeben, wenn kein Freischaltcode bereitgestellt wird. fixedValue: #unknown", "mapping": [ { "map": "medicationReference.extension[data-absent-reason].valueCode", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Wird angegeben, wenn kein Freischaltcode bereitgestellt wird. fixedValue: #unknown" }, { "id": "logMedDispenseDiGA.datum", "max": "1", "min": 1, "path": "logMedDispenseDiGA.datum", "type": [ { "code": "dateTime" } ], "short": "Abgabedatum im Format YYYY-MM-DD", "mapping": [ { "map": "whenHandedOver", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Abgabedatum im Format YYYY-MM-DD" }, { "id": "logMedDispenseDiGA.note", "max": "1", "min": 0, "path": "logMedDispenseDiGA.note", "type": [ { "code": "Annotation" } ], "short": "Wenn der Workflow abgeschlossen wird, ohne dass ein Freischaltcode bereitgestellt wird, muss dieser Wert angegeben werden.", "mapping": [ { "map": "note", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Wenn der Workflow abgeschlossen wird, ohne dass ein Freischaltcode bereitgestellt wird, muss dieser Wert angegeben werden." }, { "id": "logMedDispenseDiGA.substitution", "max": "0", "min": 0, "path": "logMedDispenseDiGA.substitution", "type": [ { "code": "BackboneElement" } ], "short": "Substitution darf lt. BAS nicht erfolgen.", "mapping": [ { "map": "substitution", "identity": "GEM-ERP-MAP-MedicationDispense-DiGA" } ], "definition": "Substitution darf lt. BAS nicht erfolgen." } ] }, "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Base" }