PackagesCanonicalsLogsProblems
    Packages
    de.medizininformatikinitiative.kerndatensatz.kardiologie@2027.0.0-ballot.rc1
    https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-score-modifizierte-rankin-skala
description: Profil zur Erfassung des Outcomes eines Schlaganfalls mittels modifizierter Rankin-Skala.
package_name: de.medizininformatikinitiative.kerndatensatz.kardiologie
derivation: constraint
name: MII_PR_Kardio_Score_Modifizierte_Rankin_Skala
type: Observation
elements:
  category:
    binding: {strength: required, valueSet: 'http://hl7.org/fhir/ValueSet/observation-category'}
    mustSupport: true
    pattern:
      type: CodeableConcept
      value:
        coding:
        - {code: survey, system: 'http://terminology.hl7.org/CodeSystem/observation-category'}
    index: 0
  code:
    mustSupport: true
    index: 1
    elements:
      coding:
        array: true
        min: 2
        index: 2
        elements:
          system: {mustSupport: true, index: 3}
          version: {mustSupport: true, index: 4}
          code: {mustSupport: true, index: 5}
        required: [version, system, code]
        slicing:
          rules: closed
          discriminator:
          - {path: $this, type: value}
          min: 2
          slices:
            sct:
              match: {code: '1255866005', system: 'http://snomed.info/sct'}
              schema:
                mustSupport: true
                pattern:
                  type: Coding
                  value: {code: '1255866005', system: 'http://snomed.info/sct'}
                _required: true
                index: 6
              min: 1
              max: 1
            loinc:
              match: {code: 75859-9, system: 'http://loinc.org'}
              schema:
                mustSupport: true
                pattern:
                  type: Coding
                  value: {code: 75859-9, system: 'http://loinc.org'}
                _required: true
                index: 7
              min: 1
              max: 1
  subject:
    type: Reference
    mustSupport: true
    refers: ['http://hl7.org/fhir/StructureDefinition/Patient']
    index: 8
  encounter: {mustSupport: true, index: 9}
  effective:
    mustSupport: true
    choices: []
    index: 11
  performer: {mustSupport: true, index: 12}
  value:
    mustSupport: true
    choices: [valueCodeableConcept]
    index: 14
  valueCodeableConcept: {type: CodeableConcept, mustSupport: true, choiceOf: value, index: 15}
package_version: 2027.0.0-ballot.rc1
class: profile
kind: resource
url: https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-score-modifizierte-rankin-skala
base: http://hl7.org/fhir/StructureDefinition/Observation
version: 2027.0.0-ballot.rc1
required: [subject, category, effective]