PackagesCanonicalsLogsProblems
    Packages
    hl7.fhir.us.cqfmeasures@1.0.0
    http://hl7.org/fhir/us/cqfmeasures/Library/exm-logic
{
  "description": "This library is used as an example in the FHIR Quality Measure Implementation Guide",
  "_filename": "example/Library-exm-logic.json",
  "package_name": "hl7.fhir.us.cqfmeasures",
  "date": "2019-09-03T00:00:00-04:00",
  "meta": {
    "profile": [ "http://hl7.org/fhir/us/cqfmeasures/StructureDefinition/library-cqfm" ],
    "versionId": "3",
    "lastUpdated": "2019-03-12T04:14:44.038-04:00"
  },
  "publisher": "Health Level 7 International - Clinical Quality Information Work Group",
  "approvalDate": "2019-08-03",
  "jurisdiction": [ {
    "coding": [ {
      "code": "US",
      "system": "urn:iso:std:iso:3166",
      "display": "United States of America"
    } ]
  } ],
  "content": [ {
    "data": "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",
    "contentType": "application/elm+xml"
  }, {
    "data": "bGlicmFyeSBFWE1fTG9naWMgdmVyc2lvbiAnMC4wLjAnCgp1c2luZyBGSElSIHZlcnNpb24gJzMuMC4wJwoKcGFyYW1ldGVyICJNZWFzdXJlbWVudCBQZXJpb2QiIEludGVydmFsPERhdGVUaW1lPgoKY29udGV4dCBQYXRpZW50Cgo=",
    "contentType": "text/cql"
  } ],
  "name": "EXM_Logic",
  "type": "{:coding [{:system \\\"http://hl7.org/fhir/library-type\\\", :code \\\"logic-library\\\"}]}",
  "experimental": "true",
  "resourceType": "Library",
  "title": "EXM Logic",
  "package_version": "1.0.0",
  "status": "active",
  "id": "ca1cabd5-0712-4ab4-9631-d310a652942e",
  "kind": null,
  "url": "http://hl7.org/fhir/us/cqfmeasures/Library/exm-logic",
  "identifier": [ {
    "use": "official",
    "value": "EXM_Logic",
    "system": "http://example.org/fhir/cqi/ecqm/Library/Identifier"
  } ],
  "lastReviewDate": "2019-08-03",
  "version": "1.0.0",
  "contact": [ {
    "telecom": [ {
      "value": "http://www.hl7.org/Special/committees/cqi/index.cfm",
      "system": "url"
    } ]
  } ]
}