{ "description": "Profile on the Communication resource which represents the reply proposal contraindication conform information standard [CiO](https://informatiestandaarden.nictiz.nl/wiki/Landingspagina_Contra-indicaties_en_Overgevoeligheden).", "_filename": "cio-ReplyProposalContraIndication.json", "package_name": "nictiz.fhir.nl.r4.cio", "date": null, "derivation": "constraint", "publisher": "Nictiz", "fhirVersion": "4.0.1", "purpose": "To define the reply proposal contraindication as stated in the information standard CiO.", "name": "CioReplyProposalContraIndication", "mapping": [ { "uri": "https://decor.nictiz.nl/pub/cio/cio-html-20241023T071643/ds-2.16.840.1.113883.2.4.3.11.60.26.1.2-2020-04-02T000000.html", "name": "ART-DECOR Dataset Contraindications and hypersensitivities 2.0.0-beta.3 20241023", "identity": "cio-dataset-200-beta3-20241023" } ], "abstract": false, "copyright": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.", "type": "Communication", "experimental": null, "resourceType": "StructureDefinition", "title": "cio ReplyProposalContraIndication", "package_version": "1.0.0-beta.5", "status": "draft", "id": "c6fbdcd7-5f22-49df-95af-e7aea0cdabfa", "kind": "resource", "url": "http://nictiz.nl/fhir/StructureDefinition/cio-ReplyProposalContraIndication", "version": "1.0.0-beta.5", "differential": { "element": [ { "id": "Communication", "path": "Communication", "alias": [ "AntwoordVoorstelContraIndicatie" ], "short": "ReplyProposalContraIndication", "comment": "Since all concepts within the ReplyProposalContraIndication building block are mapped to elements within this profile, it is not necessary to use the [cio-RegistrationInformation](http://nictiz.nl/fhir/StructureDefinition/cio-RegistrationInformation) profile to convey the RegistrationInformation concepts.", "mapping": [ { "map": "cio-dataelement-20-937", "comment": "ReplyProposalContraIndication", "identity": "cio-dataset-200-beta3-20241023" }, { "map": "cio-dataelement-20-943", "comment": "RegistrationInformation", "identity": "cio-dataset-200-beta3-20241023" } ], "definition": "The response to the proposal for registering, retracting, or modifying a medication contraindication." }, { "id": "Communication.meta", "path": "Communication.meta" }, { "id": "Communication.meta.tag", "min": 1, "path": "Communication.meta.tag", "slicing": { "rules": "open", "discriminator": [ { "path": "$this", "type": "pattern" } ] } }, { "id": "Communication.meta.tag:actionable", "max": "1", "min": 1, "path": "Communication.meta.tag", "sliceName": "actionable", "patternCoding": { "code": "actionable", "system": "http://terminology.hl7.org/CodeSystem/common-tags" } }, { "id": "Communication.identifier", "max": "1", "min": 1, "path": "Communication.identifier", "alias": [ "Identificatienummer" ], "short": "IdentificationNumber", "mapping": [ { "map": "cio-dataelement-20-780", "comment": "IdentificationNumber", "identity": "cio-dataset-200-beta3-20241023" } ], "definition": "Globally unique number that identifies the instantiation of the information model. The number is composed of an identification of the issuer organization and a unique number assigned by this organization." }, { "id": "Communication.basedOn", "min": 1, "path": "Communication.basedOn", "type": [ { "code": "Reference", "targetProfile": [ "http://hl7.org/fhir/StructureDefinition/Resource", "http://nictiz.nl/fhir/StructureDefinition/cio-MedicationContraIndication" ] } ], "alias": [ "RelatieVoorstelContraIndicatie" ], "short": "RelationProposalContraIndication", "mapping": [ { "map": "cio-dataelement-20-945", "comment": "RelationProposalContraIndication", "identity": "cio-dataset-200-beta3-20241023" } ], "definition": "Relation to the proposal contraindication to which the reply is made." }, { "id": "Communication.subject", "min": 1, "path": "Communication.subject", "type": [ { "code": "Reference", "targetProfile": [ "http://hl7.org/fhir/StructureDefinition/Patient", "http://nictiz.nl/fhir/StructureDefinition/nl-core-Patient" ] } ], "alias": [ "Patient" ], "short": "Patient", "mapping": [ { "map": "cio-dataelement-20-302", "comment": "Patient", "identity": "cio-dataset-200-beta3-20241023" } ], "definition": "The patient that was the focus of this communication." }, { "id": "Communication.sent", "min": 1, "path": "Communication.sent", "alias": [ "OntstaansDatumTijd" ], "short": "CreationDateTime", "mapping": [ { "map": "cio-dataelement-20-783", "comment": "CreationDateTime", "identity": "cio-dataset-200-beta3-20241023" } ], "definition": "Date and of the response to the proposal." }, { "id": "Communication.sender", "min": 1, "path": "Communication.sender", "type": [ { "code": "Reference", "profile": [ "http://nictiz.nl/fhir/StructureDefinition/pattern-NlCoreHealthProfessionalReference" ], "targetProfile": [ "http://hl7.org/fhir/StructureDefinition/Practitioner", "http://hl7.org/fhir/StructureDefinition/PractitionerRole", "http://nictiz.nl/fhir/StructureDefinition/nl-core-HealthProfessional-PractitionerRole" ] } ], "alias": [ "Auteur" ], "short": "Author", "mapping": [ { "map": "cio-dataelement-20-781", "comment": "Author", "identity": "cio-dataset-200-beta3-20241023" } ], "definition": "Author of the response to the proposal." }, { "id": "Communication.payload", "max": "2", "min": 1, "path": "Communication.payload", "slicing": { "rules": "open", "discriminator": [ { "path": "content.extension(url='http://nictiz.nl/fhir/5.0/StructureDefinition/extension-Communication.payload.content%5Bx%5D:contentCodeableConcept')", "type": "exists" } ] } }, { "id": "Communication.payload:responseProposalContraIndication", "max": "1", "min": 1, "path": "Communication.payload", "sliceName": "responseProposalContraIndication" }, { "id": "Communication.payload:responseProposalContraIndication.content[x]", "path": "Communication.payload.content[x]", "type": [ { "code": "string" } ] }, { "id": "Communication.payload:responseProposalContraIndication.content[x].extension", "min": 1, "path": "Communication.payload.content[x].extension" }, { "id": "Communication.payload:responseProposalContraIndication.content[x].extension:contentCodeableConcept", "min": 1, "path": "Communication.payload.content[x].extension", "type": [ { "code": "Extension", "profile": [ "http://nictiz.nl/fhir/5.0/StructureDefinition/extension-Communication.payload.content%5Bx%5D:contentCodeableConcept" ] } ], "comment": "This is a pre-adopt of R5 in which the string data type of `.payload.content` is changed to a CodeableConcept.", "sliceName": "contentCodeableConcept" }, { "id": "Communication.payload:responseProposalContraIndication.content[x].extension:contentCodeableConcept.value[x]", "min": 1, "path": "Communication.payload.content[x].extension.value[x]", "alias": [ "BeantwoordingVoorstelContraIndicatie" ], "short": "ResponseProposalContraIndication", "binding": { "strength": "required", "valueSet": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.26.11.38--20240709000000" }, "mapping": [ { "map": "cio-dataelement-20-944", "comment": "ResponseProposalContraIndication", "identity": "cio-dataset-200-beta3-20241023" } ], "definition": "The response to the proposal for registering, retracting, or modifying a medication contraindication. The proposed medication contraindication is either accepted or rejected." }, { "id": "Communication.payload:comment", "max": "1", "path": "Communication.payload", "sliceName": "comment" }, { "id": "Communication.payload:comment.content[x]", "path": "Communication.payload.content[x]", "type": [ { "code": "string" } ], "alias": [ "Toelichting" ], "short": "Comment", "mapping": [ { "map": "cio-dataelement-20-942", "comment": "Comment", "identity": "cio-dataset-200-beta3-20241023" } ], "definition": "Textual explanation of the response to the proposal contraindication. This free text field can be used to provide the reason for rejecting the proposed medication contraindication." } ] }, "contact": [ { "name": "Nictiz", "telecom": [ { "use": "work", "value": "https://www.nictiz.nl", "system": "url" } ] } ], "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Communication" }