description: null package_name: de.medizininformatikinitiative.kerndatensatz.icu derivation: constraint name: MII_PR_ICU_Bilanz_Ausfuhr_Haemofiltration_Einzelmesswerte type: Observation elements: category: elements: coding: index: 0 slicing: slices: hl7-category: match: {} schema: index: 0 elements: code: pattern: {type: Code, value: exam} index: 1 code: elements: coding: array: true min: 2 index: 2 slicing: slices: sct: match: {} schema: pattern: type: Coding value: {code: '251850009', system: 'http://snomed.info/sct', display: Ultrafiltrate fluid loss (observable entity)} _required: true index: 3 min: 1 max: 1 loinc: match: {} schema: pattern: type: Coding value: {code: 99741-1, system: 'http://loinc.org', display: Ultrafiltrate volume removed} _required: true index: 4 min: 1 max: 1 IEEE-11073: match: {} schema: {index: 5} max: 0 value[x]: elements: unit: short: Display unit (SI) mustSupport: true pattern: {type: String, value: ml} index: 6 code: binding: {strength: required, valueSet: 'https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/mii-vs-icu-unit-equivalent-ucum-milliliter'} mustSupport: true index: 7 required: [unit, code] package_version: 2026.0.2-rc.3 class: profile kind: resource url: https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-bilanz-ausfuhr-haemofiltration-einzelmesswerte base: https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-bilanz version: 2026.0.2-rc.3