{ "patient": { "reference": "Patient/example0" }, "description": null, "_filename": "Device-example0.json", "package_name": "hl7.fhir.au.base", "date": null, "publisher": null, "name": null, "type": "{:coding [{:system \\\"http://snomed.info/sct\\\", :code \\\"86184003\\\", :display \\\"Electrocardiographic monitor and recorder\\\"}], :text \\\"ECG\\\"}", "experimental": null, "resourceType": "Device", "title": null, "note": [ { "text": "QA Checked", "time": "2015-06-28T14:03:32+10:00", "authorReference": { "reference": "Practitioner/example0" } } ], "package_version": "0.9.3", "udi": { "name": "FHIR® Hip System", "issuer": "http://hl7.org/fhir/NamingSystem/gs1", "entryType": "barcode", "carrierHRF": "{01}00844588003288{17}141120{10}7654321D{21}10987654d321", "carrierAIDC": "XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH", "jurisdiction": "http://hl7.org/fhir/NamingSystem/fda-udi", "deviceIdentifier": "00844588003288" }, "status": "active", "id": "bb62df07-9520-4bce-a309-0c560ef1f30f", "safety": [ { "text": "MR Unsafe", "coding": [ { "code": "mr-unsafe", "system": "urn:oid:2.16.840.1.113883.3.26.1.1", "display": "MR Unsafe" } ] } ], "lotNumber": "43453424", "kind": null, "url": "http://acme.com/goodhealth/ehr/", "identifier": [ { "type": { "text": "PAI-D", "coding": [ { "code": "NDI", "system": "http://hl7.org.au/fhir/v2/0203", "display": "National Device Identifier" } ] }, "value": "8003640003999998" } ], "manufacturer": "Acme Devices, Inc", "version": "10.23-23423", "location": { "display": "Central Supply" }, "contact": [ { "value": "0255554352", "system": "phone" } ], "manufactureDate": "2015-08-08", "owner": { "reference": "Organization/example0" }, "expirationDate": "2020-08-08", "model": "AB 45-J" }