description: null package_name: de.medizininformatikinitiative.kerndatensatz.icu derivation: constraint name: MII_PR_ICU_VENT_Spontanes_Plus_Mechanisches_Atemzugvolumen type: Observation elements: category: pattern: type: CodeableConcept value: coding: - {code: '40617009', system: 'http://snomed.info/sct', display: Artificial ventilation (regime/therapy)} index: 0 slicing: slices: kuenstlicheBeatmung: match: {} schema: pattern: type: CodeableConcept value: coding: - {code: '40617009', system: 'http://snomed.info/sct', display: Artificial ventilation (regime/therapy)} _required: true index: 0 min: 1 max: 1 code: elements: coding: index: 1 slicing: slices: sct: match: {} schema: {index: 1} max: 0 loinc: match: {} schema: pattern: type: Coding value: {code: 20118-6, display: Tidal volume.spontaneous+mechanical --on ventilator} _required: true index: 2 min: 1 max: 1 IEEE-11073: match: {} schema: {index: 3} max: 0 value: pattern: type: Quantity value: {code: mL, system: 'http://unitsofmeasure.org'} choices: [] index: 5 package_version: 2027.0.0-ballot.rc1 class: profile kind: resource url: https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-spontanes-mechanisches-atemzugvolumen-waehrend-beatmung base: https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-parameter-von-beatmung version: 2027.0.0-ballot.rc1 required: [category]