    http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-LumenOrLine
{
  "description": "Lumen and/or line information about the infusion as defined by the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or zib) 'Infusion', modeled as a complex extension.",
  "_filename": "zib-Infusion-LumenOrLine.json",
  "package_name": "nictiz.fhir.nl.stu3.zib2017",
  "date": null,
  "derivation": "constraint",
  "publisher": "Nictiz",
  "fhirVersion": "3.0.1",
  "purpose": "To provide information about the lumens and/or lines in an infusion. Currently, there is no field avaiblable in a DeviceUseStatement resource for this information, hence the reason for this extension.",
  "name": "Zib Infusion-LumenOrLine",
  "abstract": false,
  "copyright": "CC0",
  "type": "Extension",
  "experimental": null,
  "resourceType": "StructureDefinition",
  "title": "HCIM Infusion-LumenOrLine",
  "package_version": "1.0.0",
  "status": "draft",
  "id": "b84503e6-e4a7-40a5-81b0-f7f49cc81ddc",
  "kind": "complex-type",
  "url": "http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-LumenOrLine",
  "context": [ "DeviceUseStatement" ],
  "version": "1.0.0",
  "differential": {
    "element": [ {
      "id": "Extension",
      "path": "Extension",
      "alias": [ "LumenOfLijn" ],
      "short": "LumenOrLine",
      "definition": "Container of the LumenOrLine concept. This container contains all data elements of the LumenOrLine concept.\r\n\r\nCentral lines can contain one or more lumens; peripheral infusions do not have lumens and only have one line."
    }, {
      "id": "Extension.extension",
      "path": "Extension.extension",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "url",
          "type": "value"
        } ]
      }
    }, {
      "id": "Extension.extension:LineStatus",
      "max": "1",
      "path": "Extension.extension",
      "alias": [ "LijnStatus" ],
      "short": "LineStatus",
      "sliceName": "LineStatus",
      "definition": "LineStatus is used to indicate whether it is a running infusion, whether it has been capped, or has been fitted with a heparin lock, etc."
    }, {
      "id": "Extension.extension:LineStatus.url",
      "path": "Extension.extension.url",
      "fixedUri": "LineStatus"
    }, {
      "id": "Extension.extension:LineStatus.value[x]:valueCodeableConcept",
      "path": "Extension.extension.valueCodeableConcept",
      "type": [ {
        "code": "CodeableConcept"
      } ],
      "binding": {
        "strength": "preferred",
        "description": "LineStatusCodeList",
        "valueSetReference": {
          "display": "LineStatusCodeList",
          "reference": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.2.3--20171231000000"
        }
      },
      "sliceName": "valueCodeableConcept"
    }, {
      "id": "Extension.extension:LumenLocation",
      "max": "1",
      "path": "Extension.extension",
      "alias": [ "LumenLocatie" ],
      "short": "LumenLocation",
      "sliceName": "LumenLocation",
      "definition": "For central venous catheters with multiple lumens, LumenLocation indicates the relative position of the lumen with respect to the insertion opening."
    }, {
      "id": "Extension.extension:LumenLocation.url",
      "path": "Extension.extension.url",
      "fixedUri": "LumenLocation"
    }, {
      "id": "Extension.extension:LumenLocation.value[x]:valueCodeableConcept",
      "path": "Extension.extension.valueCodeableConcept",
      "type": [ {
        "code": "CodeableConcept"
      } ],
      "binding": {
        "strength": "preferred",
        "description": "LumenLocationCodeList",
        "valueSetReference": {
          "display": "LumenLocationCodeList",
          "reference": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.2.2--20171231000000"
        }
      },
      "sliceName": "valueCodeableConcept"
    }, {
      "id": "Extension.extension:LockFluid",
      "max": "1",
      "path": "Extension.extension",
      "alias": [ "SlotVloeistof" ],
      "short": "LockFluid",
      "sliceName": "LockFluid",
      "definition": "The description of the fluid used as an anticoagulation lock, such as heparin."
    }, {
      "id": "Extension.extension:LockFluid.url",
      "path": "Extension.extension.url",
      "fixedUri": "LockFluid"
    }, {
      "id": "Extension.extension:LockFluid.value[x]:valueReference",
      "path": "Extension.extension.valueReference",
      "type": [ {
        "code": "Reference",
        "targetProfile": "http://nictiz.nl/fhir/StructureDefinition/zib-MedicationAdministration"
      } ],
      "sliceName": "valueReference"
    }, {
      "id": "Extension.extension:AdministeringSystem",
      "path": "Extension.extension",
      "alias": [ "ToedieningsSysteem" ],
      "short": "AdministeringSystem",
      "sliceName": "AdministeringSystem",
      "definition": "The administering system contains the entire system making the fluid run from the infusion bag via the cannula/catheter to the patient. This also includes any three-way valves/connecting joints used."
    }, {
      "id": "Extension.extension:AdministeringSystem.url",
      "path": "Extension.extension.url",
      "fixedUri": "AdministeringSystem"
    }, {
      "id": "Extension.extension:AdministeringSystem.value[x]:valueReference",
      "path": "Extension.extension.valueReference",
      "type": [ {
        "code": "Reference"
      } ],
      "sliceName": "valueReference"
    }, {
      "id": "Extension.url",
      "path": "Extension.url",
      "fixedUri": "http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-LumenOrLine"
    }, {
      "id": "Extension.value[x]",
      "max": "0",
      "path": "Extension.value[x]",
      "type": [ {
        "code": "base64Binary"
      }, {
        "code": "boolean"
      }, {
        "code": "code"
      }, {
        "code": "date"
      }, {
        "code": "dateTime"
      }, {
        "code": "decimal"
      }, {
        "code": "id"
      }, {
        "code": "instant"
      }, {
        "code": "integer"
      }, {
        "code": "markdown"
      }, {
        "code": "oid"
      }, {
        "code": "positiveInt"
      }, {
        "code": "string"
      }, {
        "code": "time"
      }, {
        "code": "unsignedInt"
      }, {
        "code": "uri"
      }, {
        "code": "Address"
      }, {
        "code": "Age"
      }, {
        "code": "Annotation"
      }, {
        "code": "Attachment"
      }, {
        "code": "CodeableConcept"
      }, {
        "code": "Coding"
      }, {
        "code": "ContactPoint"
      }, {
        "code": "Count"
      }, {
        "code": "Distance"
      }, {
        "code": "Duration"
      }, {
        "code": "HumanName"
      }, {
        "code": "Identifier"
      }, {
        "code": "Money"
      }, {
        "code": "Period"
      }, {
        "code": "Quantity"
      }, {
        "code": "Range"
      }, {
        "code": "Ratio"
      }, {
        "code": "Reference"
      }, {
        "code": "SampledData"
      }, {
        "code": "Signature"
      }, {
        "code": "Timing"
      }, {
        "code": "Reference",
        "targetProfile": "http://nictiz.nl/fhir/StructureDefinition/zib-MedicationAdministration"
      } ]
    } ]
  },
  "contact": [ {
    "name": "Nictiz",
    "telecom": [ {
      "use": "work",
      "value": "info@nictiz.nl",
      "system": "email"
    } ]
  } ],
  "contextType": "resource",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension"
}