{ "description": "This resource is part of Infusion as defined by the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or ZIB) version 3.2, release 2017.\\r\\n\\r\\nThe administering system contains the entire system making the fluid run from the infusion bag via the cannula/catheter to the patient. This also includes any three-way valves/connecting joints used.", "_filename": "zib-Infusion-AdministeringSystem.json", "package_name": "nictiz.fhir.nl.stu3.zib2017", "date": null, "derivation": "constraint", "publisher": "Nictiz", "fhirVersion": "3.0.1", "purpose": "The purpose of an infusion is usually to administer fluid and/or medication. \r\nInformation on present infusions is recorded to inform other health professionals. This information is of importance in determining the care required for the patient and in safely administering medication. In a transfer situation, the information offers the option to realize continuity of care by organizing specific expertise and materials in advance, for example.", "name": "Zib Infusion AdministeringSystem", "mapping": [ { "uri": "https://zibs.nl/wiki/Infusion-v3.2(2017EN)", "name": "HCIM Infusion-v3.2(2017EN)", "identity": "hcim-infusion-v3.2-2017EN" } ], "abstract": false, "copyright": "CC0", "type": "MedicationAdministration", "experimental": null, "resourceType": "StructureDefinition", "title": "HCIM Infusion AdministeringSystem", "package_version": "1.0.0", "status": "draft", "id": "b4365941-389c-4c42-b880-ef8ed44c81e6", "kind": "resource", "url": "http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-AdministeringSystem", "version": "1.0.0", "differential": { "element": [ { "id": "MedicationAdministration", "path": "MedicationAdministration", "mapping": [ { "map": "NL-CM:10.2.2", "comment": "InfusionFluid", "identity": "hcim-infusion-v3.2-2017EN" } ] }, { "id": "MedicationAdministration.device.extension", "path": "MedicationAdministration.device.extension", "slicing": { "rules": "open", "discriminator": [ { "path": "url", "type": "value" } ] } }, { "path": "MedicationAdministration.device.extension", "definition": "A description of medical devices required for administering the infusion fluid and placing the catheter, such as a volumetric infusion pump, syringe and infusion bag.", "short": "Peripheral", "mapping": [ { "map": "NL-CM:10.2.6", "comment": "Peripheral", "identity": "hcim-infusion-v3.2-2017EN" } ], "type": [ { "code": "Extension", "profile": "http://nictiz.nl/fhir/StructureDefinition/extension-medicaldevice" } ], "sliceName": "Peripheral", "alias": [ "Randapparaat" ], "id": "MedicationAdministration.device.extension:Peripheral", "comment": "Use the direct reference to the Device resource (MedicationAdministration.device.reference) when no meta data regarding the use of the device is available or needed." }, { "id": "MedicationAdministration.note.text", "path": "MedicationAdministration.note.text", "alias": [ "ToedieningsSysteemToelichting" ], "short": "AdministeringSystemComment", "mapping": [ { "map": "NL-CM:10.2.12", "comment": "AdministeringSystemComment", "identity": "hcim-infusion-v3.2-2017EN" } ], "definition": "A comment on the administering system." } ] }, "contact": [ { "name": "Nictiz", "telecom": [ { "use": "work", "value": "info@nictiz.nl", "system": "email" } ] } ], "baseDefinition": "http://nictiz.nl/fhir/StructureDefinition/zib-MedicationAdministration" }