{ "description": "This profile is for submitting whether the patient received enteral nutrition.", "_filename": "NICE-FeedingTubeSystem.json", "package_name": "niceprofiling.v23q1", "date": "2021-11-03T10:28:27.5445855+00:00", "derivation": "constraint", "meta": { "lastUpdated": "2022-07-14T10:35:43.8297312+00:00" }, "publisher": "NICE", "fhirVersion": "3.0.2", "purpose": "This profile is used to submit feeding tube related information to the Dutch National Intensive Care Evaluation (NICE). It was derived from the Nictiz Health and Care Information Model (HCIM; Dutch: Zorginformatiebouwsteen or ZIB) FeedingTubeSystem, 2017 release version 3.1", "name": "NICE-FeedingTubeSystem", "mapping": [ { "uri": "https://www.stichting-nice.nl/dd/#561", "name": "NICE-Datadictionary-Capacity", "comment": "The Patient acuity registration", "identity": "NICE-Datadictionary-Capacity" } ], "abstract": false, "copyright": "CC0", "type": "DeviceUseStatement", "experimental": null, "resourceType": "StructureDefinition", "title": "NICE-FeedingTubeSystem", "package_version": "0.2.0", "status": "active", "id": "b3cdedc4-b2c3-4a3b-9e3d-8512a44bcf66", "kind": "resource", "url": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-FeedingTubeSystem-2022Q1", "version": "1", "differential": { "element": [ { "id": "DeviceUseStatement", "path": "DeviceUseStatement", "mapping": [ { "map": "https://www.stichting-nice.nl/dd/#612", "comment": "Nutrition - enteral", "identity": "NICE-Datadictionary-Capacity" } ] }, { "id": "DeviceUseStatement.extension", "min": 1, "path": "DeviceUseStatement.extension", "slicing": { "rules": "open", "discriminator": [ { "path": "url", "type": "value" } ] } }, { "id": "DeviceUseStatement.extension:MedicalDevice", "max": "0", "min": 0, "path": "DeviceUseStatement.extension", "slicing": { "rules": "open", "discriminator": [ { "path": "url", "type": "value" } ] }, "sliceName": "MedicalDevice" }, { "id": "DeviceUseStatement.extension:Verified", "max": "1", "min": 1, "path": "DeviceUseStatement.extension", "type": [ { "code": "Extension", "profile": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Verified-2022Q1" } ], "short": "Is the instance validated by a medical professional?", "sliceName": "Verified", "definition": "Extension that is used to indicate whether the entire instance has been validated.\r\n\r\nEvery instance shall be validated by a hospital member / datamanager. However, this is not always feasible in case of automated submission of NICE data elements. This extensions shall be used to indicate the validation status of the instance." }, { "id": "DeviceUseStatement.extension:HealthcareProvider", "max": "0", "path": "DeviceUseStatement.extension", "sliceName": "HealthcareProvider" }, { "id": "DeviceUseStatement.extension:HealthProfessional", "max": "0", "path": "DeviceUseStatement.extension", "sliceName": "HealthProfessional" }, { "id": "DeviceUseStatement.extension:reasonReference", "max": "0", "path": "DeviceUseStatement.extension", "sliceName": "reasonReference" }, { "id": "DeviceUseStatement.extension:FeedingTubeLength", "max": "0", "path": "DeviceUseStatement.extension", "sliceName": "FeedingTubeLength" }, { "id": "DeviceUseStatement.extension:EnteralNutrition", "max": "0", "path": "DeviceUseStatement.extension", "sliceName": "EnteralNutrition" }, { "id": "DeviceUseStatement.status", "path": "DeviceUseStatement.status", "short": "validated (completed)", "fixedCode": "completed" }, { "id": "DeviceUseStatement.subject", "path": "DeviceUseStatement.subject", "type": [ { "code": "Reference", "targetProfile": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Patient-2022Q1" } ] }, { "id": "DeviceUseStatement.whenUsed", "path": "DeviceUseStatement.whenUsed", "mustSupport": true }, { "id": "DeviceUseStatement.whenUsed.start", "path": "DeviceUseStatement.whenUsed.start", "mustSupport": true }, { "id": "DeviceUseStatement.whenUsed.end", "path": "DeviceUseStatement.whenUsed.end", "mustSupport": true } ] }, "contact": [ { "name": "NICE", "telecom": [ { "value": "vragen@stichting-nice.nl", "system": "email" } ] } ], "baseDefinition": "http://nictiz.nl/fhir/StructureDefinition/zib-FeedingTubeSystem" }