description: 'This template is intended to be used in addition to the **Product Instance** template urn:oid:2.16.840.1.113883.10.20.22.4.37 to exchange the **Device Identifier** (also known as the \"Primary DI Number\") for a medical device marketed in the US. The device identifier is parsed from the UDI value.\n\nThe Device Identifier number can be used as a key to look-up device identification information in the publicly available version of the US FDA Global UDI Database (GUDID) - the AccessGUDID: https://accessgudid.nlm.nih.gov/resources/home' package_name: hl7.cda.us.ccda derivation: constraint name: DeviceIdentifierObservation type: http://hl7.org/cda/stds/core/StructureDefinition/Observation elements: templateId: index: 0 slicing: rules: open discriminator: - {path: root, type: value} - {path: extension, type: value} min: 1 slices: device-id-obs: match: {root: 2.16.840.1.113883.10.20.22.4.304, extension: '2022-06-01'} schema: _required: true index: 1 elements: root: pattern: {type: String, value: 2.16.840.1.113883.10.20.22.4.304} index: 2 extension: pattern: {type: String, value: '2022-06-01'} index: 3 required: [root, extension] extensions: {} code: short: Primary DI Number Code from NCIt index: 4 elements: code: pattern: {type: Code, value: C101722} index: 5 codeSystem: pattern: {type: String, value: 2.16.840.1.113883.3.26.1.1} index: 6 codeSystemName: {short: MAY be set to 'NCI Thesaurus', index: 7} displayName: {short: MAY be set to 'Primary DI Number', index: 8} required: [codeSystem, code] text: short: SHOULD reference the portion of section narrative text corresponding to this entry index: 9 elements: reference: constraint: value-starts-octothorpe: {human: 'If reference/@value is present, it SHALL begin with a ''#'' and SHALL point to its corresponding narrative', source: 'http://hl7.org/cda/us/ccda/StructureDefinition/DeviceIdentifierObservation', severity: error, expression: value.exists() implies value.startsWith('#')} index: 10 value: type: http://hl7.org/cda/stds/core/StructureDefinition/II short: This value is assigned by the Manufacturer by using an FDA-accredited UDI-issuing agency constraint: should-extension: {human: SHOULD contain extension, source: 'http://hl7.org/cda/us/ccda/StructureDefinition/DeviceIdentifierObservation', severity: warning, expression: extension.exists()} index: 11 elements: displayable: pattern: {type: Boolean, value: true} index: 12 root: {index: 13} extension: {index: 14} required: [root, displayable] extensions: {} package_version: 3.0.0-ballot class: logical kind: logical url: http://hl7.org/cda/us/ccda/StructureDefinition/DeviceIdentifierObservation base: http://hl7.org/cda/stds/core/StructureDefinition/Observation version: 3.0.0-ballot required: [value, templateId]