"description": "This profile defines the expected capabilities of a Da Vinci DEQM Reporter Client when conforming to the Da Vinci DEQM Implementation Guide. Reporters are the systems that calculate quality measure results and submit them to a Receiver. Note that a system acting as a Consumer in an exchange scenario commonly acts as the Reporter in a subsequent reporting scenario. This CapabilityStatement resource includes the complete list of the *recommended* Da Vinci DEQM profiles and RESTful operations that a Da Vinci DEQM Reporter Client could support. Clients have the option of choosing from this list based on their local use cases and other contextual requirements.",
"_filename": "CapabilityStatement-reporter-client.json",
"package_name": "hl7.fhir.uv.deqm",
"format": [ "xml", "json" ],
"date": "2020-07-05",
"publisher": "HL7 International / Clinical Quality Information",
"patchFormat": [ "application/json-patch+json" ],
"fhirVersion": "4.0.1",
"jurisdiction": [ {
"coding": [ {
"code": "001",
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"display": "World"
} ]
} ],
"name": "ReporterClientCapabilityStatement",
"type": null,
"experimental": "false",
"resourceType": "CapabilityStatement",
"title": "Reporter Client CapabilityStatement",
"package_version": "1.0.0",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "cqi"
}, {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 4,
"_valueInteger": {
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueCanonical": "http://hl7.org/fhir/uv/deqm/ImplementationGuide/hl7.fhir.uv.deqm"
} ]
}
}, {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode": "trial-use",
"_valueCode": {
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueCanonical": "http://hl7.org/fhir/uv/deqm/ImplementationGuide/hl7.fhir.uv.deqm"
} ]
}
} ],
"status": "active",
"id": "94a723dd-86d5-470b-a5f8-771f6aebb7d8",
"kind": "requirements",
"implementationGuide": [ "http://hl7.org/fhir/uv/deqm/ImplementationGuide/hl7.fhir.uv.deqm", "http://hl7.org/fhir/uv/cqm/ImplementationGuide/hl7.fhir.uv.cqm" ],
"url": "http://hl7.org/fhir/uv/deqm/CapabilityStatement/reporter-client",
"version": "1.0.0",
"contact": [ {
"telecom": [ {
"value": "http://www.hl7.org/Special/committees/cqi",
"system": "url"
} ]
} ],
"rest": [ {
"mode": "client",
"resource": [ {
"type": "MeasureReport",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHALL"
} ],
"interaction": [ {
"code": "create",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHALL"
} ]
}, {
"code": "update",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
}, {
"code": "delete",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
} ],
"documentation": "The DaVinci DEQM Reporter Client **SHALL** be capable of supporting at least one of the DEQM MeasureReport Profiles listed above and all the DEQM, CQM and QI Core Profiles they reference.",
"supportedProfile": [ "http://hl7.org/fhir/uv/deqm/StructureDefinition/deqm-summarymeasurereport", "http://hl7.org/fhir/uv/deqm/StructureDefinition/deqm-individualmeasurereport", "http://hl7.org/fhir/uv/deqm/StructureDefinition/deqm-subjectlistmeasurereport" ]
} ],
"security": {
"description": "For general security consideration refer to the [Security and Privacy Considerations](http://hl7.org/fhir/R4/secpriv-module.html)."
},
"interaction": [ {
"code": "transaction",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "MAY"
} ]
}, {
"code": "batch",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "MAY"
} ]
}, {
"code": "search-system",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "MAY"
} ]
}, {
"code": "history-system",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "MAY"
} ]
} ],
"documentation": "Da Vinci DEQM Producer Client **SHALL** support at least one of the following transactions defined in the *Framework* Section of this Implementation Guide:\n\n- Individual Reporting\n- Summary Reporting\n\n\nDEQM Producer Client **SHALL** support at least one of 'batch' or 'transaction'."
} ]
}