PackagesCanonicalsLogsProblems
    Packages
    hl7.fhir.uv.pocd@0.3.0
    http://hl7.org/fhir/uv/pocd/CodeSystem/safety
{
  "description": "CodeSystem for IEEE 11073-10207 SafetyClassification",
  "_filename": "CodeSystem-safety.json",
  "package_name": "hl7.fhir.uv.pocd",
  "date": "2020-05-12",
  "meta": {
    "profile": [ "http://hl7.org/fhir/StructureDefinition/shareablecodesystem" ]
  },
  "publisher": "HL7 International - Devices Work Group",
  "jurisdiction": [ {
    "coding": [ {
      "code": "001",
      "system": "http://unstats.un.org/unsd/methods/m49/m49.htm"
    } ]
  } ],
  "content": "complete",
  "name": "Safety",
  "type": null,
  "experimental": "false",
  "resourceType": "CodeSystem",
  "title": "Safety",
  "package_version": "0.3.0",
  "status": "draft",
  "id": "8de59c4c-c017-4a25-83f7-bc23c10aa21c",
  "kind": null,
  "url": "http://hl7.org/fhir/uv/pocd/CodeSystem/safety",
  "concept": [ {
    "code": "Inf",
    "display": "Informational",
    "definition": "The descriptor and the related state information are intended to be used for information purposes only. They are not intended to be used in clinical functions."
  }, {
    "code": "MedA",
    "display": "Medical Class A",
    "definition": "Medical Class A. The descriptor and related state information are intended to be used in clinical functions, specifically for general display in order to support patient and device monitoring. The displayed data is not intended to be used as sole source for diagnostic or therapeutic decisions. Deviations from this intended use are in the sole responsibility of the SERVICE CONSUMER."
  }, {
    "code": "MedB",
    "display": "Medical Class B",
    "definition": "AThe descriptor and related state information are intended to be used in clinical functions. The manufacturer has specified and considered a specific intended use for the data, which could result in nonserious injury. Deviations from this intended use are in the sole responsibility of the SERVICE CONSUMER."
  }, {
    "code": "MedC",
    "display": "Medical Class C",
    "definition": "The descriptor and related state information are intended to be used in clinical functions. The manufacturer has specified and considered a specific intended use for the data, which could result in serious injury. Deviations from this intended use are in the sole responsibility of the SERVICE CONSUMER."
  } ],
  "caseSensitive": false,
  "version": "0.3.0",
  "contact": [ {
    "telecom": [ {
      "value": "http://hl7.org/Special/committees/healthcaredevices",
      "system": "url"
    } ]
  } ]
}