    https://fhir.hl7.org.uk/StructureDefinition/UKCore-Specimen
description: This profile defines the UK constraints and extensions on the International FHIR resource [Specimen](https://hl7.org/fhir/R4/Specimen.html).
package_name: fhir.r4.ukcore.stu3.currentbuild
derivation: constraint
name: UKCoreSpecimen
type: Specimen
elements:
  extension:
    type: Extension
    short: An extension to record the category of a sample.
    isModifier: false
    url: https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-SampleCategory
    index: 0
    slicing:
      slices:
        sampleCategory:
          match: {}
          schema: {type: Extension, short: An extension to record the category of a sample., isModifier: false, url: 'https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-SampleCategory', index: 0}
          max: 1
  status: {short: The availability of the specimen sample., mustSupport: true, index: 1}
  type:
    short: The kind of material that forms the specimen.
    binding: {strength: preferred, valueSet: 'https://fhir.hl7.org.uk/ValueSet/UKCore-SpecimenType'}
    mustSupport: true
    index: 2
  subject: {short: Where the specimen came from., mustSupport: true, index: 3}
  receivedTime: {short: The time when specimen was received for processing., mustSupport: true, index: 4}
  collection:
    extensions:
      specialHandling: {url: 'http://hl7.org/fhir/StructureDefinition/specimen-specialHandling', type: Extension, short: This SHOULD be included if there is a high contamination risk reason for a sample / biopsy., index: 5}
    elements:
      extension:
        type: Extension
        short: This SHOULD be included if there is a high contamination risk reason for a sample / biopsy.
        url: http://hl7.org/fhir/StructureDefinition/specimen-specialHandling
        index: 5
        slicing:
          slices:
            specialHandling:
              match: {}
              schema: {type: Extension, short: This SHOULD be included if there is a high contamination risk reason for a sample / biopsy., url: 'http://hl7.org/fhir/StructureDefinition/specimen-specialHandling', index: 5}
      bodySite:
        binding: {strength: preferred, valueSet: 'https://fhir.hl7.org.uk/ValueSet/UKCore-SpecimenBodySite'}
        index: 6
  container:
    elements:
      type: {index: 7}
  condition:
    binding: {strength: extensible, valueSet: 'https://fhir.hl7.org.uk/ValueSet/UKCore-SampleState'}
    index: 8
package_version: 0.28.0-pre-release
extensions:
  sampleCategory: {url: 'https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-SampleCategory', max: 1, type: Extension, short: An extension to record the category of a sample., isModifier: false, index: 0}
class: profile
kind: resource
url: https://fhir.hl7.org.uk/StructureDefinition/UKCore-Specimen
base: http://hl7.org/fhir/StructureDefinition/Specimen
version: 4.0.0