PackagesCanonicalsLogsProblems
    Packages
    de.medizininformatikinitiative.kerndatensatz.icu@2024.0.0-alpha2
    https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/sauerstoffsaettigung-im-blut-preduktal-durch-pulsoxymetrie
{
  "description": null,
  "_filename": "sd-mii-icu-muv-o2saettigung-im-blut-preduktal-durch-pulsoxymetrie.json",
  "package_name": "de.medizininformatikinitiative.kerndatensatz.icu",
  "date": null,
  "derivation": "constraint",
  "publisher": null,
  "fhirVersion": "4.0.1",
  "name": "SD_MII_ICU_Sauerstoffsaettigung_Im_Blut_Preduktal_Durch_Pulsoxymetrie",
  "abstract": false,
  "type": "Observation",
  "experimental": null,
  "resourceType": "StructureDefinition",
  "title": "SD MII ICU Sauerstoffsaettigung Im Blut Preduktal Durch Pulsoxymetrie",
  "package_version": "2024.0.0-alpha2",
  "status": "active",
  "id": "7ba7d489-2ee1-422b-9d9f-4a8db73307c6",
  "kind": "resource",
  "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/sauerstoffsaettigung-im-blut-preduktal-durch-pulsoxymetrie",
  "version": "1.0.0",
  "differential": {
    "element": [ {
      "id": "Observation.code.coding",
      "min": 2,
      "path": "Observation.code.coding"
    }, {
      "id": "Observation.code.coding:sct",
      "max": "0",
      "path": "Observation.code.coding",
      "sliceName": "sct",
      "patternCoding": {
        "system": "http://snomed.info/sct"
      }
    }, {
      "id": "Observation.code.coding:loinc",
      "max": "1",
      "min": 1,
      "path": "Observation.code.coding",
      "sliceName": "loinc",
      "patternCoding": {
        "code": "59407-7",
        "system": "http://loinc.org"
      }
    }, {
      "id": "Observation.code.coding:IEEE-11073",
      "max": "1",
      "min": 1,
      "path": "Observation.code.coding",
      "sliceName": "IEEE-11073",
      "patternCoding": {
        "code": "160296",
        "system": "urn:iso:std:iso:11073:10101"
      }
    }, {
      "id": "Observation.code.coding:loinc-fhir-core",
      "path": "Observation.code.coding",
      "sliceName": "loinc-fhir-core",
      "mustSupport": true,
      "patternCoding": {
        "code": "2708-6",
        "system": "http://loinc.org"
      }
    }, {
      "id": "Observation.code.coding:loinc-fhir-core.system",
      "min": 1,
      "path": "Observation.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.code.coding:loinc-fhir-core.code",
      "min": 1,
      "path": "Observation.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.value[x]",
      "path": "Observation.value[x]",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "type"
        } ]
      }
    }, {
      "id": "Observation.value[x]:valueQuantity",
      "path": "Observation.value[x]",
      "sliceName": "valueQuantity",
      "patternQuantity": {
        "code": "%",
        "unit": "percent",
        "system": "http://unitsofmeasure.org"
      }
    }, {
      "id": "Observation.value[x]:valueQuantity.unit",
      "min": 1,
      "path": "Observation.value[x].unit"
    } ]
  },
  "baseDefinition": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/monitoring-und-vitaldaten"
}