    https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1
{
  "description": "Extension that is used to describe how the medical device is used.",
  "_filename": "NICE-PacemakerUsage.json",
  "package_name": "niceprofiling.v23q1",
  "date": "2021-12-10T12:43:51.6381668+00:00",
  "derivation": "constraint",
  "meta": {
    "lastUpdated": "2021-12-10T12:46:36.658+00:00"
  },
  "publisher": "NICE",
  "fhirVersion": "3.0.2",
  "name": "NICE-PacemakerUsage",
  "abstract": false,
  "copyright": "CC0",
  "type": "Extension",
  "experimental": null,
  "resourceType": "StructureDefinition",
  "title": "NICE-PacemakerUsage",
  "package_version": "0.5.0",
  "status": "active",
  "id": "7a35899a-2408-458f-a6bf-2ad8899e70ea",
  "kind": "complex-type",
  "url": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1",
  "context": [ "DeviceUseStatement" ],
  "version": "0.0.1",
  "differential": {
    "element": [ {
      "id": "DeviceUseStatement.extension:Verified",
      "max": "1",
      "min": 1,
      "path": "DeviceUseStatement.extension",
      "type": [ {
        "code": "Extension",
        "profile": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Verified-2022Q1"
      } ],
      "short": "Is the instance validated by a medical professional?",
      "sliceName": "Verified",
      "definition": "Extension that is used to indicate whether the entire instance has been validated.\r\n\r\nEvery instance shall be validated by a hospital member / datamanager. However, this is not always feasible in case of automated submission of NICE data elements. This extensions shall be used to indicate the validation status of the instance."
    }, {
      "id": "Extension",
      "path": "Extension",
      "short": "Pacemaker usage",
      "definition": "The specific use of the external pacemaker is defined here."
    }, {
      "id": "Extension.url",
      "path": "Extension.url",
      "fixedUri": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1"
    }, {
      "id": "Extension.value[x]:valueCodeableConcept",
      "path": "Extension.valueCodeableConcept",
      "type": [ {
        "code": "CodeableConcept"
      } ],
      "sliceName": "valueCodeableConcept"
    }, {
      "id": "Extension.value[x]:valueCodeableConcept.coding",
      "path": "Extension.valueCodeableConcept.coding",
      "binding": {
        "strength": "required",
        "description": "PacemakerUsage",
        "valueSetUri": "https://fhir.stichting-nice.nl/ValueSet/NICE-PacemakerUsage"
      },
      "definition": "The pacing of a heart via an external pacemaker (atrial or ventricular pacing) is understood to mean that a minimum 50% of the heart’s activity is initiated by the external pacemaker.\r\n\r\nThe pacemaker ‘standby’ is understood to mean that the pacemaker is physically connected to the patient, but that less than 50% of heart activity is initiated by the external pacemaker."
    } ]
  },
  "contact": [ {
    "name": "NICE",
    "telecom": [ {
      "value": "vragen@stichting-nice.nl",
      "system": "email"
    } ]
  } ],
  "contextType": "resource",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension"
}