{ "description": "Extension that is used to describe how the medical device is used.", "_filename": "NICE-PacemakerUsage.json", "package_name": "niceprofiling.v23q1", "date": "2021-12-10T12:43:51.6381668+00:00", "derivation": "constraint", "meta": { "lastUpdated": "2021-12-10T12:46:36.658+00:00" }, "publisher": "NICE", "fhirVersion": "3.0.2", "name": "NICE-PacemakerUsage", "abstract": false, "copyright": "CC0", "type": "Extension", "experimental": null, "resourceType": "StructureDefinition", "title": "NICE-PacemakerUsage", "package_version": "0.3.0", "status": "active", "id": "63b069c9-4afd-406a-8c4e-63c8fc378a7d", "kind": "complex-type", "url": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1", "context": [ "DeviceUseStatement" ], "version": "0.0.1", "differential": { "element": [ { "id": "DeviceUseStatement.extension:Verified", "max": "1", "min": 1, "path": "DeviceUseStatement.extension", "type": [ { "code": "Extension", "profile": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Verified-2022Q1" } ], "short": "Is the instance validated by a medical professional?", "sliceName": "Verified", "definition": "Extension that is used to indicate whether the entire instance has been validated.\r\n\r\nEvery instance shall be validated by a hospital member / datamanager. However, this is not always feasible in case of automated submission of NICE data elements. This extensions shall be used to indicate the validation status of the instance." }, { "id": "Extension", "path": "Extension", "short": "Pacemaker usage", "definition": "The specific use of the external pacemaker is defined here." }, { "id": "Extension.url", "path": "Extension.url", "fixedUri": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1" }, { "id": "Extension.value[x]:valueCodeableConcept", "path": "Extension.valueCodeableConcept", "type": [ { "code": "CodeableConcept" } ], "sliceName": "valueCodeableConcept" }, { "id": "Extension.value[x]:valueCodeableConcept.coding", "path": "Extension.valueCodeableConcept.coding", "binding": { "strength": "required", "description": "PacemakerUsage", "valueSetUri": "https://fhir.stichting-nice.nl/ValueSet/NICE-PacemakerUsage" }, "definition": "The pacing of a heart via an external pacemaker (atrial or ventricular pacing) is understood to mean that a minimum 50% of the heart’s activity is initiated by the external pacemaker.\r\n\r\nThe pacemaker ‘standby’ is understood to mean that the pacemaker is physically connected to the patient, but that less than 50% of heart activity is initiated by the external pacemaker." } ] }, "contact": [ { "name": "NICE", "telecom": [ { "value": "vragen@stichting-nice.nl", "system": "email" } ] } ], "contextType": "resource", "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension" }