"description": null,
"_filename": "mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung.json",
"package_name": "de.medizininformatikinitiative.kerndatensatz.icu",
"date": null,
"derivation": "constraint",
"publisher": "Medizininformatik Initiative",
"fhirVersion": "4.0.1",
"name": "MII_PR_ICU_Devicemetric_Eingestellte_Gemessene_Parameter_Beatmung",
"abstract": false,
"type": "DeviceMetric",
"experimental": null,
"resourceType": "StructureDefinition",
"title": "MII PR ICU DeviceMetric Eingestellte Gemessene Parameter Beatmung",
"package_version": "2026.0.0-ballot",
"status": "active",
"id": "61ac40b0-8dba-4d51-abad-be335db224bc",
"kind": "resource",
"url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/devicemetric-eingestellte-gemessene-parameter-beatmung",
"version": "2025.0.4",
"differential": {
"element": [ {
"id": "DeviceMetric.type",
"path": "DeviceMetric.type",
"binding": {
"strength": "required",
"valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/vs-mii-icu-category-procedure-beatmung-snomed"
},
"mustSupport": true
}, {
"id": "DeviceMetric.type.coding",
"path": "DeviceMetric.type.coding",
"mustSupport": true,
"patternCoding": {
"system": "http://snomed.info/sct"
}
}, {
"id": "DeviceMetric.type.coding.system",
"min": 1,
"path": "DeviceMetric.type.coding.system",
"mustSupport": true
}, {
"id": "DeviceMetric.type.coding.code",
"min": 1,
"path": "DeviceMetric.type.coding.code",
"mustSupport": true
}, {
"id": "DeviceMetric.source",
"path": "DeviceMetric.source",
"type": [ {
"code": "Reference",
"targetProfile": [ "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/icu-device" ]
} ],
"mustSupport": true
}, {
"id": "DeviceMetric.category",
"path": "DeviceMetric.category",
"mustSupport": true
} ]
},
"contact": [ {
"telecom": [ {
"value": "https://www.medizininformatik-initiative.de",
"system": "url"
} ]
} ],
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/DeviceMetric"
}