PackagesCanonicalsLogsProblems
    Packages
    de.gematik.isik-vitalparameter@4.0.0-alpha-validation-MII
    https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-zentralvenoeser-blutdruck
{
  "description": null,
  "_filename": "StructureDefinition-sd-mii-icu-zentralvenoeser-blutdruck.json",
  "package_name": "de.gematik.isik-vitalparameter",
  "date": "2024-02-01",
  "derivation": "constraint",
  "publisher": "gematik GmbH",
  "fhirVersion": "4.0.1",
  "name": "SD_MII_ICU_Zentralvenoeser_Blutdruck",
  "mapping": [ {
    "uri": "http://hl7.org/fhir/workflow",
    "name": "Workflow Pattern",
    "identity": "workflow"
  }, {
    "uri": "http://snomed.info/conceptdomain",
    "name": "SNOMED CT Concept Domain Binding",
    "identity": "sct-concept"
  }, {
    "uri": "http://hl7.org/v2",
    "name": "HL7 v2 Mapping",
    "identity": "v2"
  }, {
    "uri": "http://hl7.org/v3",
    "name": "RIM Mapping",
    "identity": "rim"
  }, {
    "uri": "http://hl7.org/fhir/fivews",
    "name": "FiveWs Pattern Mapping",
    "identity": "w5"
  }, {
    "uri": "http://snomed.org/attributebinding",
    "name": "SNOMED CT Attribute Binding",
    "identity": "sct-attr"
  } ],
  "abstract": false,
  "type": "Observation",
  "experimental": "false",
  "resourceType": "StructureDefinition",
  "title": "SD MII ICU Zentralvenoeser Blutdruck",
  "package_version": "4.0.0-alpha-validation-MII",
  "status": "active",
  "id": "60f8e0c8-8d7f-477c-bf9e-6f79f462c52d",
  "kind": "resource",
  "url": "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-zentralvenoeser-blutdruck",
  "version": "4.0.0-rc",
  "differential": {
    "element": [ {
      "id": "Observation.code.coding:loinc",
      "path": "Observation.code.coding",
      "sliceName": "loinc",
      "patternCoding": {
        "code": "60985-9",
        "system": "http://loinc.org"
      }
    }, {
      "id": "Observation.code.coding:snomed",
      "path": "Observation.code.coding",
      "sliceName": "snomed",
      "patternCoding": {
        "code": "71420008",
        "system": "http://snomed.info/sct"
      }
    }, {
      "id": "Observation.code.coding:IEEE-11073",
      "path": "Observation.code.coding",
      "sliceName": "IEEE-11073",
      "patternCoding": {
        "code": "150084",
        "system": "urn:iso:std:iso:11073:10101"
      }
    }, {
      "id": "Observation.value[x]:valueQuantity",
      "path": "Observation.value[x]",
      "type": [ {
        "code": "Quantity"
      } ],
      "sliceName": "valueQuantity"
    }, {
      "id": "Observation.value[x]:valueQuantity.code",
      "path": "Observation.value[x].code",
      "patternCode": "mm[Hg]"
    } ]
  },
  "baseDefinition": "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-monitoring-und-vitaldaten"
}