description: Negation profile of DeviceRequest for decision support/quality metrics. Indicates a proposal, plan, or order not to provide a device. package_name: rs/hl7.fhir.us.qicore derivation: constraint name: QICoreDeviceProhibited type: DeviceRequest elements: modifierExtension: isModifier: true short: (QI) Extension type: Extension url: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform isModifierReason: The do not perform element changes the meaning of the request from a positive to a negative statement index: 0 slicing: slices: doNotPerform: match: {} schema: isModifier: true short: (QI) Extension type: Extension url: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform isModifierReason: The do not perform element changes the meaning of the request from a positive to a negative statement index: 0 elements: value: short: (QI) Value of extension pattern: {type: boolean, value: true} choices: [valueBoolean] type: boolean index: 2 valueBoolean: short: (QI) Value of extension type: boolean choiceOf: value pattern: {type: boolean, value: true} index: 3 required: [value, valueBoolean] authoredOn: {short: (QI) When recorded, index: 4} reasonCode: type: CodeableConcept short: (QI) Explanation/Justification for procedure or service binding: {strength: extensible, valueSet: 'http://hl7.org/fhir/us/qicore/ValueSet/qicore-negation-reason'} index: 5 package_version: 7.0.0 class: profile kind: resource url: http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-deviceprohibited base: http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-devicerequest version: 7.0.0 required: [authoredOn]