    http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate
description: The US Core Heart Rate Profile inherits from the US Core Vital Signs Profile. This profile sets minimum expectations for the Observation resource to record, search,  and fetch heart rate observations with a standard LOINC code and UCUM units of measure. It specifies which *additional*  core elements, extensions,  vocabularies, and value sets **SHALL** be present in the resource and constrains how the elements are used. Providing the floor for standards development for specific use cases promotes interoperability and adoption.
package_name: hl7.fhir.us.core
derivation: constraint
name: USCoreHeartRateProfile
type: Observation
elements:
  code:
    type: CodeableConcept
    short: Heart Rate
    mustSupport: true
    pattern:
      type: CodeableConcept
      value:
        coding:
        - {code: 8867-4, system: 'http://loinc.org'}
    index: 0
  valueQuantity:
    short: Vital Signs Value
    mustSupport: true
    index: 1
    elements:
      value: {type: decimal, mustSupport: true, index: 2}
      unit: {type: string, mustSupport: true, index: 3}
      system:
        type: uri
        pattern: {type: Uri, value: 'http://unitsofmeasure.org'}
        mustSupport: true
        index: 4
      code:
        type: code
        short: Coded responses from the common UCUM units for vital signs value set.
        pattern: {type: Code, value: /min}
        mustSupport: true
        index: 5
    required: [value, unit, system, code]
package_version: 7.0.0
class: profile
kind: resource
url: http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate
base: http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs
version: 7.0.0