PackagesCanonicalsLogsProblems
    Packages
    hl7.fhir.uv.ips@1.1.0
    http://hl7.org/fhir/uv/ips/ValueSet/results-radiology-numobs-snomed-dicom-uv-ips
{
  "description": "Extensible value set including SNOMED CT and DICOM concepts for Linear, Area and Volume Measurements",
  "compose": {
    "include": [ {
      "system": "http://dicom.nema.org/resources/ontology/DCM",
      "concept": [ {
        "code": "121207",
        "display": "Height"
      }, {
        "code": "121211",
        "display": "Path length"
      }, {
        "code": "121206",
        "display": "Distance"
      } ]
    }, {
      "system": "http://snomed.info/sct",
      "concept": [ {
        "code": "410668003",
        "display": "Length"
      }, {
        "code": "103355008",
        "display": "Width"
      }, {
        "code": "131197000",
        "display": "Depth"
      }, {
        "code": "81827009",
        "display": "Diameter"
      }, {
        "code": "103339001",
        "display": "Long Axis"
      }, {
        "code": "103340004",
        "display": "Short Axis"
      }, {
        "code": "131187009",
        "display": "Major Axis"
      }, {
        "code": "131188004",
        "display": "Minor Axis"
      }, {
        "code": "131189007",
        "display": "Perpendicular Axis"
      }, {
        "code": "131190003",
        "display": "Radius"
      }, {
        "code": "131191004",
        "display": "Perimeter"
      }, {
        "code": "74551000",
        "display": "Circumference"
      }, {
        "code": "131192006",
        "display": "Diameter of circumscribed circle"
      } ],
      "version": "http://snomed.info/sct/900000000000207008"
    }, {
      "system": "http://snomed.info/sct",
      "concept": [ {
        "code": "42798000",
        "display": "Area"
      }, {
        "code": "131184002",
        "display": "Area of defined region"
      } ],
      "version": "http://snomed.info/sct/900000000000207008"
    }, {
      "system": "http://dicom.nema.org/resources/ontology/DCM",
      "concept": [ {
        "code": "121216",
        "display": "Volume estimated from single 2D region"
      }, {
        "code": "121218",
        "display": "Volume estimated from two non-coplanar 2D regions"
      }, {
        "code": "121217",
        "display": "Volume estimated from three or more non-coplanar 2D regions"
      }, {
        "code": "121222",
        "display": "Volume of sphere"
      }, {
        "code": "121221",
        "display": "Volume of ellipsoid"
      }, {
        "code": "121220",
        "display": "Volume of circumscribed sphere"
      }, {
        "code": "121219",
        "display": "Volume of bounding three dimensional region"
      } ]
    }, {
      "system": "http://snomed.info/sct",
      "concept": [ {
        "code": "118565006",
        "display": "Volume"
      } ],
      "version": "http://snomed.info/sct/900000000000207008"
    } ]
  },
  "_filename": "ValueSet-results-radiology-numobs-snomed-dicom-uv-ips.json",
  "package_name": "hl7.fhir.uv.ips",
  "date": "2022-11-22T03:24:39+00:00",
  "meta": {
    "profile": [ "http://hl7.org/fhir/StructureDefinition/shareablevalueset" ]
  },
  "publisher": "Health Level Seven International - Patient Care Work Group",
  "jurisdiction": [ {
    "coding": [ {
      "code": "001",
      "system": "http://unstats.un.org/unsd/methods/m49/m49.htm"
    } ]
  } ],
  "name": "ResultsRadiologyMeasurementObservationSnomedDicomUvIps",
  "copyright": "The HL7 International IPS implementation guides incorporate SNOMED CT®, used by permission of the International Health Terminology Standards Development Organisation, trading as SNOMED International. SNOMED CT was originally created by the College of American Pathologists. SNOMED CT is a registered trademark of the International Health Terminology Standards Development Organisation, all rights reserved. Implementers of SNOMED CT should review [usage terms](http://www.snomed.org/snomed-ct/get-snomed-ct) or directly contact SNOMED International: info@snomed.org",
  "type": null,
  "experimental": "false",
  "resourceType": "ValueSet",
  "title": "Results Radiology Measurement Observation (SNOMED-DICOM) - IPS",
  "package_version": "1.1.0",
  "extension": [ {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
    "valueInteger": 2,
    "_valueInteger": {
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
        "valueCanonical": "http://hl7.org/fhir/uv/ips/ImplementationGuide/ig-uv-ips"
      } ]
    }
  }, {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
    "valueCode": "trial-use",
    "_valueCode": {
      "extension": [ {
        "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
        "valueCanonical": "http://hl7.org/fhir/uv/ips/ImplementationGuide/ig-uv-ips"
      } ]
    }
  } ],
  "status": "active",
  "id": "42727b0e-d83c-4c12-955d-5103391b39eb",
  "kind": null,
  "url": "http://hl7.org/fhir/uv/ips/ValueSet/results-radiology-numobs-snomed-dicom-uv-ips",
  "immutable": false,
  "version": "1.1.0",
  "contact": [ {
    "telecom": [ {
      "value": "http://www.hl7.org/Special/committees/patientcare",
      "system": "url"
    } ]
  } ]
}