{ "description": "Mapping between DICOM® SR Measurement Report and FHIR Resources", "_filename": "ConceptMap-dicom-sr-measurement-report-to-fhir.json", "package_name": "hl7.fhir.uv.dicom-sr", "date": "2024-08-09T16:26:36+00:00", "targetScopeUri": "Bundle", "group": [ { "element": [ { "code": "DICOM.Patient", "target": [ { "code": "Patient[1]", "comment": "The DICOM® SR Patient IE is mapped to a FHIR Patient resource", "display": "Patient[1]", "relationship": "equivalent" } ], "display": "Patient IE" } ] }, { "element": [ { "code": "DICOM.Study", "target": [ { "code": "ImagingStudy[1]", "comment": "The DICOM® SR Study IE is mapped to a FHIR ImagingStudy resource", "display": "ImagingStudy[1]", "relationship": "equivalent" } ], "display": "Study IE" }, { "code": "DICOM.Study", "target": [ { "code": "ServiceRequest[1]", "comment": "The DICOM® SR Study IE is mapped to a FHIR ServiceRequest resource", "display": "ServiceRequest[1]", "relationship": "related-to" } ], "display": "Study IE" } ] }, { "element": [ { "code": "DICOM.Equipment", "target": [ { "code": "Device[1]", "comment": "The DICOM® SR Equipment IE may result in the creation of a new Device resource", "display": "Device[1]", "relationship": "equivalent" } ], "display": "Equipment IE" } ] }, { "element": [ { "code": "DICOM.Document", "target": [ { "code": "Observation[1]", "comment": "Processing of the Document IE will result in the creation one or more new Observation resources", "display": "Observation[1]", "property": [ { "code": "imaging-measurement-group-map", "valueString": "dicom-imaging-measurement-group-to-fhir" }, { "code": "references", "valueString": "Observation.subject.reference=Patient[1].id" }, { "code": "references", "valueString": "Observation.partOf.reference=ImagingStudy[1].id" }, { "code": "references", "valueString": "Observation.basedOn.reference=ServiceRequest[1].id" }, { "code": "references", "valueString": "Observation.device.reference=Device[1]" } ], "relationship": "source-is-narrower-than-target" } ], "display": "Document IE" } ] } ], "publisher": "HL7 International / Imaging Integration", "jurisdiction": [ { "coding": [ { "code": "001", "system": "http://unstats.un.org/unsd/methods/m49/m49.htm" } ] } ], "property": [ { "code": "references", "type": "string" }, { "code": "imaging-measurement-group-map", "type": "string" } ], "name": "DICOMSRMeasurementReportToFHIRMapping", "type": null, "experimental": "false", "resourceType": "ConceptMap", "title": "ConceptMap - DICOM SR Measurement Report to FHIR Mapping", "package_version": "1.0.0-ballot", "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode": "ii" } ], "status": "active", "id": "3d6a8248-5d9a-4183-acc2-ca6861fd064d", "kind": null, "url": "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-sr-measurement-report-to-fhir", "identifier": [ { "value": "urn:oid:2.16.840.1.113883.4.642.40.39.18.7", "system": "urn:ietf:rfc:3986" } ], "version": "1.0.0-ballot", "contact": [ { "telecom": [ { "value": "http://www.hl7.org/Special/committees/imagemgt", "system": "url" } ] }, { "name": "HL7 International / Imaging Integration", "telecom": [ { "value": "http://www.hl7.org/Special/committees/imagemgt", "system": "url" } ] }, { "name": "Jonathan Whitby", "telecom": [ { "value": "jonathan.whitby@mi.medical.canon", "system": "email" }, { "value": "http://www.hl7.org/Special/committees/imagemgt", "system": "url" } ] }, { "name": "Christopher Lindop", "telecom": [ { "value": "Christopher.Lindop@ge.com", "system": "email" }, { "value": "http://www.hl7.org/Special/committees/imagemgt", "system": "url" } ] } ], "sourceScopeUri": "DICOM-SR-Measurement-Report" }