PackagesCanonicalsLogsProblems
    Packages
    hl7.fhir.uv.dicom-sr@1.0.0-ballot
    http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-sr-measurement-report-to-fhir
{
  "description": "Mapping between DICOM® SR Measurement Report and FHIR Resources",
  "_filename": "ConceptMap-dicom-sr-measurement-report-to-fhir.json",
  "package_name": "hl7.fhir.uv.dicom-sr",
  "date": "2024-08-09T16:26:36+00:00",
  "targetScopeUri": "Bundle",
  "group": [ {
    "element": [ {
      "code": "DICOM.Patient",
      "target": [ {
        "code": "Patient[1]",
        "comment": "The DICOM® SR Patient IE is mapped to a FHIR Patient resource",
        "display": "Patient[1]",
        "relationship": "equivalent"
      } ],
      "display": "Patient IE"
    } ]
  }, {
    "element": [ {
      "code": "DICOM.Study",
      "target": [ {
        "code": "ImagingStudy[1]",
        "comment": "The DICOM® SR Study IE is mapped to a FHIR ImagingStudy resource",
        "display": "ImagingStudy[1]",
        "relationship": "equivalent"
      } ],
      "display": "Study IE"
    }, {
      "code": "DICOM.Study",
      "target": [ {
        "code": "ServiceRequest[1]",
        "comment": "The DICOM® SR Study IE is mapped to a FHIR ServiceRequest resource",
        "display": "ServiceRequest[1]",
        "relationship": "related-to"
      } ],
      "display": "Study IE"
    } ]
  }, {
    "element": [ {
      "code": "DICOM.Equipment",
      "target": [ {
        "code": "Device[1]",
        "comment": "The DICOM® SR Equipment IE may result in the creation of a new Device resource",
        "display": "Device[1]",
        "relationship": "equivalent"
      } ],
      "display": "Equipment IE"
    } ]
  }, {
    "element": [ {
      "code": "DICOM.Document",
      "target": [ {
        "code": "Observation[1]",
        "comment": "Processing of the Document IE will result in the creation one or more new Observation resources",
        "display": "Observation[1]",
        "property": [ {
          "code": "imaging-measurement-group-map",
          "valueString": "dicom-imaging-measurement-group-to-fhir"
        }, {
          "code": "references",
          "valueString": "Observation.subject.reference=Patient[1].id"
        }, {
          "code": "references",
          "valueString": "Observation.partOf.reference=ImagingStudy[1].id"
        }, {
          "code": "references",
          "valueString": "Observation.basedOn.reference=ServiceRequest[1].id"
        }, {
          "code": "references",
          "valueString": "Observation.device.reference=Device[1]"
        } ],
        "relationship": "source-is-narrower-than-target"
      } ],
      "display": "Document IE"
    } ]
  } ],
  "publisher": "HL7 International / Imaging Integration",
  "jurisdiction": [ {
    "coding": [ {
      "code": "001",
      "system": "http://unstats.un.org/unsd/methods/m49/m49.htm"
    } ]
  } ],
  "property": [ {
    "code": "references",
    "type": "string"
  }, {
    "code": "imaging-measurement-group-map",
    "type": "string"
  } ],
  "name": "DICOMSRMeasurementReportToFHIRMapping",
  "type": null,
  "experimental": "false",
  "resourceType": "ConceptMap",
  "title": "ConceptMap - DICOM SR Measurement Report to FHIR Mapping",
  "package_version": "1.0.0-ballot",
  "extension": [ {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
    "valueCode": "ii"
  } ],
  "status": "active",
  "id": "3d6a8248-5d9a-4183-acc2-ca6861fd064d",
  "kind": null,
  "url": "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-sr-measurement-report-to-fhir",
  "identifier": [ {
    "value": "urn:oid:2.16.840.1.113883.4.642.40.39.18.7",
    "system": "urn:ietf:rfc:3986"
  } ],
  "version": "1.0.0-ballot",
  "contact": [ {
    "telecom": [ {
      "value": "http://www.hl7.org/Special/committees/imagemgt",
      "system": "url"
    } ]
  }, {
    "name": "HL7 International / Imaging Integration",
    "telecom": [ {
      "value": "http://www.hl7.org/Special/committees/imagemgt",
      "system": "url"
    } ]
  }, {
    "name": "Jonathan Whitby",
    "telecom": [ {
      "value": "jonathan.whitby@mi.medical.canon",
      "system": "email"
    }, {
      "value": "http://www.hl7.org/Special/committees/imagemgt",
      "system": "url"
    } ]
  }, {
    "name": "Christopher Lindop",
    "telecom": [ {
      "value": "Christopher.Lindop@ge.com",
      "system": "email"
    }, {
      "value": "http://www.hl7.org/Special/committees/imagemgt",
      "system": "url"
    } ]
  } ],
  "sourceScopeUri": "DICOM-SR-Measurement-Report"
}