{ "description": "ImplementationGuide for Point-of-Care Devices (PoCD), such as those typically found in a hospital care setting (e.g., physiological monitors, infusion pumps, ventilators, pulse-oximeters, etc.).", "_filename": "ImplementationGuide-hl7.fhir.uv.pocd.json", "package_name": "hl7.fhir.uv.pocd", "definition": { "page": { "page": [ { "title": "Home", "nameUrl": "index.html", "generation": "markdown" }, { "title": "Overview", "nameUrl": "overview.html", "generation": "markdown" }, { "title": "Abbreviations and Definitions", "nameUrl": "definitions.html", "generation": "markdown" }, { "page": [ { "title": "HL7 V2 Mapping", "nameUrl": "mappingv2.html", "generation": "markdown" }, { "title": "Mapping from IEEE 11073-10201 DIM to FHIR", "nameUrl": "mappingdim.html", "generation": "markdown" }, { "title": "Mapping from IEEE 11073-10207 SDC to FHIR", "nameUrl": "mappingsdc.html", "generation": "markdown" }, { "title": "RESTful Transfer", "nameUrl": "transfer.html", "generation": "markdown" } ], "title": "Technical Implementation Guidance", "nameUrl": "guidance.html", "generation": "markdown" }, { "title": "Profiles", "nameUrl": "profiles.html", "generation": "html" }, { "title": "Terminology", "nameUrl": "terminology.html", "generation": "html" }, { "title": "Artifact List", "nameUrl": "artifacts.html", "generation": "html" }, { "title": "Downloads", "nameUrl": "downloads.html", "generation": "html" }, { "title": "Change Log", "nameUrl": "changes.html", "generation": "html" } ], "title": "Table of Contents", "nameUrl": "toc.html", "generation": "html" }, "resource": [ { "name": "Server CapabilityStatement", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "CapabilityStatement" } ], "reference": { "reference": "CapabilityStatement/ServerCapabilityStatement" }, "description": "CapabilityStatement that describes the expected capabilities of a server processing data from Point-of-Care devices.", "exampleBoolean": false }, { "name": "MDS Device profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/MdsDevice" }, "description": "StructureDefinition for Device resources that represent a Medical Device System (MDS). This is the top-level resource in the hierarchical model of a Point-of-Care device.", "exampleBoolean": false }, { "name": "VMD Device profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/VmdDevice" }, "description": "StructureDefinition for Device resources that represent Virtual Medical Devices (VMD). These are medical-related subsystems in the hierarchical model of a Point-of-Care device.", "exampleBoolean": false }, { "name": "Channel Device profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/ChannelDevice" }, "description": "StructureDefinition for Device resources that represent Channels, which are used for grouping metrics together.", "exampleBoolean": false }, { "name": "Numeric DeviceMetric profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/NumericDeviceMetric" }, "description": "StructureDefinition for DeviceMetric resources that represent numerical measurements, calculations, or settings characteristics and capabilities.", "exampleBoolean": false }, { "name": "Enumeration DeviceMetric profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/EnumerationDeviceMetric" }, "description": "StructureDefinition for DeviceMetric resources that represent coded or text status, annotations, or settings characteristics and capabilities.", "exampleBoolean": false }, { "name": "Sample Array DeviceMetric profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/SampleArrayDeviceMetric" }, "description": "StructureDefinition for DeviceMetric resources that represent real-time waveforms or wave snippets characteristics and capabilities.", "exampleBoolean": false }, { "name": "Numeric Observation profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/NumericObservation" }, "description": "StructureDefinition for Observation resources that represent numerical measurements, calculations, or settings.", "exampleBoolean": false }, { "name": "Compound Numeric Observation profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/CompoundNumericObservation" }, "description": "StructureDefinition for Observation resources that represent numerical measurements, calculations, or settings with multiple components.", "exampleBoolean": false }, { "name": "Enumeration Observation profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/EnumerationObservation" }, "description": "StructureDefinition for Observation resources that represent coded or text status, annotations, or settings.", "exampleBoolean": false }, { "name": "Sample Array Observation profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/SampleArrayObservation" }, "description": "StructureDefinition for Observation resources that represent real-time waveforms or wave snippets.", "exampleBoolean": false }, { "name": "Patient profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/Patient" }, "description": "StructureDefinition for Patient resources that represent demographics and other administrative information.", "exampleBoolean": false }, { "name": "Practitioner profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/Practitioner" }, "description": "StructureDefinition for Practitioner resources that represent demographics and other administrative information.", "exampleBoolean": false }, { "name": "Observation profile", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:resource" } ], "reference": { "reference": "StructureDefinition/Observation" }, "description": "StructureDefinition for measurements and simple assertions made about a patient, device or other subject.", "exampleBoolean": false }, { "name": "Device Instance extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/device-instance" }, "description": "StructureDefinition that adds an instance number or label to Device or DeviceMetric.", "exampleBoolean": false }, { "name": "Approved Jurisdictions extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/approved-jurisdictions" }, "description": "StructureDefinition that adds approved jurisdictions to a Device.", "exampleBoolean": false }, { "name": "Operator extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/operator" }, "description": "StructureDefinition that adds an operator to a Device.", "exampleBoolean": false }, { "name": "Operating hours extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/operating-hours" }, "description": "StructureDefinition that adds operating hours to a Device.", "exampleBoolean": false }, { "name": "Operating cycles extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/operating-cycles" }, "description": "StructureDefinition that adds operating cycles to a Device.", "exampleBoolean": false }, { "name": "Operating mode extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/operating-mode" }, "description": "StructureDefinition that adds an operating mode to a Device.", "exampleBoolean": false }, { "name": "Relation extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/relation" }, "description": "StructureDefinition that adds relations to a DeviceMetric.", "exampleBoolean": false }, { "name": "Metric availability extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/metric-availability" }, "description": "StructureDefinition that adds metric availability to a DeviceMetric.", "exampleBoolean": false }, { "name": "Technical range extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/technical-range" }, "description": "StructureDefinition that adds technical range and accuracy to a DeviceMetric.", "exampleBoolean": false }, { "name": "Resolution extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/resolution" }, "description": "StructureDefinition that adds resolution to a DeviceMetric.", "exampleBoolean": false }, { "name": "Sweep Speed extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/sweep-speed" }, "description": "StructureDefinition that adds default sweep speed to a DeviceMetric.", "exampleBoolean": false }, { "name": "Visual Grid extension", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "StructureDefinition:extension" } ], "reference": { "reference": "StructureDefinition/visual-grid" }, "description": "StructureDefinition that adds grid line definitions to a DeviceMetric.", "exampleBoolean": false }, { "name": "Operating mode code system", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "CodeSystem" } ], "reference": { "reference": "CodeSystem/operating-mode" }, "description": "Operating mode definitions from the ISO/IEEE 11073-10207.", "exampleBoolean": false }, { "name": "Safety classification code system", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "CodeSystem" } ], "reference": { "reference": "CodeSystem/safety" }, "description": "Safety classification definitions from the ISO/IEEE 11073-10207.", "exampleBoolean": false }, { "name": "Kind of relation code system", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "CodeSystem" } ], "reference": { "reference": "CodeSystem/kind-of-relation" }, "description": "Relation definitions from the ISO/IEEE 11073-10207.", "exampleBoolean": false }, { "name": "Metric availability code system", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "CodeSystem" } ], "reference": { "reference": "CodeSystem/metric-availability" }, "description": "Metric availability definitions from the ISO/IEEE 11073-10207.", "exampleBoolean": false }, { "name": "Measurement status codes", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "CodeSystem" } ], "reference": { "reference": "CodeSystem/measurement-status" }, "description": "Measurement status definitions from the ISO/IEEE 11073-10201 DIM.", "exampleBoolean": false }, { "name": "MDC Object infrastructure and Device nomenclature", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "ValueSet" } ], "reference": { "reference": "ValueSet/11073MDC-object" }, "description": "ValueSet for the ISO/IEEE 11073-10101 Nomenclature filtered by Object partition.", "exampleBoolean": false }, { "name": "MDC Metric nomenclature", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "ValueSet" } ], "reference": { "reference": "ValueSet/11073MDC-metric" }, "description": "ValueSet for the ISO/IEEE 11073-10101 Nomenclature filtered by Metric (SCADA or Settings) partition.", "exampleBoolean": false }, { "name": "MDC Unit of Measurement", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "ValueSet" } ], "reference": { "reference": "ValueSet/11073MDC-dimension" }, "description": "ValueSet for the ISO/IEEE 11073-10101 Nomenclature filtered by Dimension partition.", "exampleBoolean": false }, { "name": "Operating mode value set", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "ValueSet" } ], "reference": { "reference": "ValueSet/operating-mode" }, "description": "ValueSet for IEEE 11073-10207 MdsState/OperatingMode.", "exampleBoolean": false }, { "name": "Safety classification value set", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "ValueSet" } ], "reference": { "reference": "ValueSet/safety" }, "description": "ValueSet for IEEE 11073-10207 SafetyClassification.", "exampleBoolean": false }, { "name": "Kind of relation value set", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "ValueSet" } ], "reference": { "reference": "ValueSet/kind-of-relation" }, "description": "ValueSet for IEEE 11073-10207 Relation/Kind.", "exampleBoolean": false }, { "name": "Metric availability value set", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "ValueSet" } ], "reference": { "reference": "ValueSet/metric-availability" }, "description": "ValueSet for IEEE 11073-10207 MetricAvailability.", "exampleBoolean": false }, { "name": "Observation interpretation codes", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "ValueSet" } ], "reference": { "reference": "ValueSet/observation-interpretation" }, "description": "Observation interpretation codes including measurement status.", "exampleBoolean": false }, { "name": "Patient Monitor MDS example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Device" } ], "reference": { "reference": "Device/PhysioMonitorMdsDevice" }, "description": "Example of a Device resource that represents a patient monitor.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/MdsDevice" }, { "name": "ECG VMD example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Device" } ], "reference": { "reference": "Device/ECGVmdDevice" }, "description": "Example of a Device resource that represents an ECG subsystem.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/VmdDevice" }, { "name": "ECG Channel example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Device" } ], "reference": { "reference": "Device/ECGChannelDevice" }, "description": "Example of a Device resource that represents an ECG channel.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/ChannelDevice" }, { "name": "ECG Sample Array metric example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "DeviceMetric" } ], "reference": { "reference": "DeviceMetric/ECGSampleArrayDeviceMetric" }, "description": "Example of a DeviceMetric resource that represents an ECG metric.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/SampleArrayDeviceMetric" }, { "name": "ECG Sample Array observation example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Observation" } ], "reference": { "reference": "Observation/ECGSampleArrayObservation" }, "description": "Example of an Observation resource that represents ECG waveforms.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/SampleArrayObservation" }, { "name": "Rhythm Status Enumeration metric example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "DeviceMetric" } ], "reference": { "reference": "DeviceMetric/RhythmStatusEnumerationDeviceMetric" }, "description": "Example of a DeviceMetric resource that represents a rhythm status metric.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/EnumerationDeviceMetric" }, { "name": "Rhythm Status Enumeration observation example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Observation" } ], "reference": { "reference": "Observation/RhythmStatusEnumerationObservation" }, "description": "Example of an Observation resource that represents coded rhythm status.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/EnumerationObservation" }, { "name": "Heart Rate Channel example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Device" } ], "reference": { "reference": "Device/HeartRateChannelDevice" }, "description": "Example of a Device resource that represents a heart rate channel.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/ChannelDevice" }, { "name": "Heart Rate Numeric metric example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "DeviceMetric" } ], "reference": { "reference": "DeviceMetric/HeartRateNumericDeviceMetric" }, "description": "Example of a DeviceMetric resource that represents a heart rate metric.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/NumericDeviceMetric" }, { "name": "Heart Rate Numeric observation example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Observation" } ], "reference": { "reference": "Observation/HeartRateNumericObservation" }, "description": "Example of an Observation resource that represents heart rate measurement.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/NumericObservation" }, { "name": "Blood Pressure VMD example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Device" } ], "reference": { "reference": "Device/BloodPressureVmdDevice" }, "description": "Example of a Device resource that represents an invasive blood pressure subsystem.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/VmdDevice" }, { "name": "Blood Pressure Channel example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Device" } ], "reference": { "reference": "Device/BloodPressureChannelDevice" }, "description": "Example of a Device resource that represents an invasive blood pressure channel.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/ChannelDevice" }, { "name": "CVP Sample Array metric example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "DeviceMetric" } ], "reference": { "reference": "DeviceMetric/CVPSampleArrayDeviceMetric" }, "description": "Example of a DeviceMetric resource that represents a central venous pressure metric.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/SampleArrayDeviceMetric" }, { "name": "CVP Sample Array observation example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Observation" } ], "reference": { "reference": "Observation/CVPSampleArrayObservation" }, "description": "Example of an Observation resource that represents central venous pressure waveform.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/SampleArrayObservation" }, { "name": "NBP VMD example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Device" } ], "reference": { "reference": "Device/NBPVmdDevice" }, "description": "Example of a Device resource that represents a non-invasive blood pressure subsystem.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/VmdDevice" }, { "name": "NBP Channel example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Device" } ], "reference": { "reference": "Device/NBPChannelDevice" }, "description": "Example of a Device resource that represents a non-invasive blood pressure channel.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/ChannelDevice" }, { "name": "NBP Numeric metric example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "DeviceMetric" } ], "reference": { "reference": "DeviceMetric/NBPNumericDeviceMetric" }, "description": "Example of a DeviceMetric resource that represents a non-invasive blood pressure metric.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/NumericDeviceMetric" }, { "name": "NBP Numeric observation example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Observation" } ], "reference": { "reference": "Observation/NBPCompoundNumericObservation" }, "description": "Example of an Observation resource that represents non-invasive blood pressure measurement.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/CompoundNumericObservation" }, { "name": "Some Patient example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Patient" } ], "reference": { "reference": "Patient/SomePatient" }, "description": "Example of a Patient resource.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/Patient" }, { "name": "Some Practitioner example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Practitioner" } ], "reference": { "reference": "Practitioner/SomePractitioner" }, "description": "Example of a Practitioner resource.", "exampleCanonical": "http://hl7.org/fhir/uv/pocd/StructureDefinition/Practitioner" }, { "name": "Some Location example", "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information", "valueString": "Location" } ], "reference": { "reference": "Location/SomeLocation" }, "description": "Example of a Location resource.", "exampleBoolean": true } ], "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "copyrightyear" }, { "url": "value", "valueString": "2017+" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "releaselabel" }, { "url": "value", "valueString": "STU 1 Ballot" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "show-inherited-invariants" }, { "url": "value", "valueString": "false" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "autoload-resources" }, { "url": "value", "valueString": "true" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "path-liquid" }, { "url": "value", "valueString": "template/liquid" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "path-liquid" }, { "url": "value", "valueString": "input/liquid" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "path-qa" }, { "url": "value", "valueString": "temp/qa" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "path-temp" }, { "url": "value", "valueString": "temp/pages" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "path-output" }, { "url": "value", "valueString": "output" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "path-suppressed-warnings" }, { "url": "value", "valueString": "input/ignoreWarnings.txt" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "path-history" }, { "url": "value", "valueString": "http://hl7.org/fhir/uv/pocd/history.html" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "template-html" }, { "url": "value", "valueString": "template-page.html" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "template-md" }, { "url": "value", "valueString": "template-page-md.html" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "apply-contact" }, { "url": "value", "valueString": "true" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "apply-context" }, { "url": "value", "valueString": "true" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "apply-copyright" }, { "url": "value", "valueString": "true" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "apply-jurisdiction" }, { "url": "value", "valueString": "true" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "apply-license" }, { "url": "value", "valueString": "true" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "apply-publisher" }, { "url": "value", "valueString": "true" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "apply-version" }, { "url": "value", "valueString": "true" } ] }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-parameter", "extension": [ { "url": "code", "valueString": "active-tables" }, { "url": "value", "valueString": "true" } ] } ], "parameter": [ { "code": "path-resource", "value": "input/capabilities" }, { "code": "path-resource", "value": "input/examples" }, { "code": "path-resource", "value": "input/extensions" }, { "code": "path-resource", "value": "input/models" }, { "code": "path-resource", "value": "input/operations" }, { "code": "path-resource", "value": "input/profiles" }, { "code": "path-resource", "value": "input/resources" }, { "code": "path-resource", "value": "input/vocabulary" }, { "code": "path-resource", "value": "input/maps" }, { "code": "path-resource", "value": "input/testing" }, { "code": "path-resource", "value": "input/history" }, { "code": "path-resource", "value": "fsh-generated/resources" }, { "code": "path-pages", "value": "template/config" }, { "code": "path-pages", "value": "input/images" }, { "code": "path-tx-cache", "value": "input-cache/txcache" } ] }, "date": "2021-08-06", "publisher": "HL7 International - Devices Work Group", "fhirVersion": [ "4.0.1" ], "license": "CC0-1.0", "jurisdiction": [ { "coding": [ { "code": "001", "system": "http://unstats.un.org/unsd/methods/m49/m49.htm" } ] } ], "name": "PoCDImplementationGuide", "type": null, "experimental": "false", "resourceType": "ImplementationGuide", "title": "Point-of-Care Device Implementation Guide", "package_version": "0.3.0", "status": "draft", "id": "396499a9-9200-477f-b8a6-98c8df97a0e4", "kind": null, "url": "http://hl7.org/fhir/uv/pocd/ImplementationGuide/hl7.fhir.uv.pocd", "version": "0.3.0", "packageId": "hl7.fhir.uv.pocd", "contact": [ { "telecom": [ { "value": "http://hl7.org/Special/committees/healthcaredevices", "system": "url" } ] } ] }