{ "description": "Example of LOINC Change Set including all new Document Attachments defined in LOINC 2.77 for pre-adoption on 2.76 implementations", "_filename": "CodeSystem-loinc277attachmentsChangeSet.json", "package_name": "hl7.fhir.uv.termchangeset", "date": "2024-08-14T14:53:44+00:00", "versionNeeded": false, "meta": { "profile": [ "http://hl7.org/fhir/uv/termchangeset/StructureDefinition/loinc-changeset-profile" ] }, "publisher": "HL7 International / Terminology Infrastructure", "jurisdiction": [ { "coding": [ { "code": "001", "system": "http://unstats.un.org/unsd/methods/m49/m49.htm" } ] } ], "content": "fragment", "property": [ { "uri": "http://loinc.org/property/STATUS", "code": "STATUS", "type": "string", "description": "Status of the term. Within LOINC, codes with STATUS=DEPRECATED are considered inactive. Current values: ACTIVE, TRIAL, DISCOURAGED, and DEPRECATED" }, { "uri": "http://loinc.org/property/COMPONENT", "code": "COMPONENT", "type": "Coding", "description": "First major axis-component or analyte: Analyte Name, Analyte sub-class, Challenge" }, { "uri": "http://loinc.org/property/PROPERTY", "code": "PROPERTY", "type": "Coding", "description": "Second major axis-property observed: Kind of Property (also called kind of quantity)" }, { "uri": "http://loinc.org/property/TIME_ASPCT", "code": "TIME_ASPCT", "type": "Coding", "description": "Third major axis-timing of the measurement: Time Aspect (Point or moment in time vs. time interval)" }, { "uri": "http://loinc.org/property/SYSTEM", "code": "SYSTEM", "type": "Coding", "description": "Fourth major axis-type of specimen or system: System (Sample) Type" }, { "uri": "http://loinc.org/property/SCALE_TYP", "code": "SCALE_TYP", "type": "Coding", "description": "Fifth major axis-scale of measurement: Type of Scale" }, { "uri": "http://loinc.org/property/METHOD_TYP", "code": "METHOD_TYP", "type": "Coding", "description": "Sixth major axis-method of measurement: Type of Method" }, { "uri": "http://loinc.org/property/CLASS", "code": "CLASS", "type": "Coding", "description": "An arbitrary classification of terms for grouping related observations together" }, { "uri": "http://loinc.org/property/VersionLastChanged", "code": "VersionLastChanged", "type": "string", "description": "The LOINC version number in which the record has last changed. For new records, this field contains the same value as the VersionFirstReleased property." }, { "uri": "http://loinc.org/property/CLASSTYPE", "code": "CLASSTYPE", "type": "string", "description": "1=Laboratory class; 2=Clinical class; 3=Claims attachments; 4=Surveys" }, { "uri": "http://loinc.org/property/ORDER_OBS", "code": "ORDER_OBS", "type": "string", "description": "Provides users with an idea of the intended use of the term by categorizing it as an order only, observation only, or both" }, { "uri": "http://loinc.org/property/HL7_ATTACHMENT_STRUCTURE", "code": "HL7_ATTACHMENT_STRUCTURE", "type": "string", "description": "This property is populated in collaboration with the HL7 Payer-Provider Exchange (PIE) Work Group (previously called Attachments Work Group) as described in the HL7 Attachment Specification: Supplement to Consolidated CDA Templated Guide." }, { "uri": "http://loinc.org/property/VersionFirstReleased", "code": "VersionFirstReleased", "type": "string", "description": "This is the LOINC version number in which this LOINC term was first published." }, { "uri": "http://loinc.org/property/ValidHL7AttachmentRequest", "code": "ValidHL7AttachmentRequest", "type": "string", "description": "A value of Y in this field indicates that this LOINC code can be sent by a payer as part of an HL7 Attachment request for additional information." } ], "name": "LOINC_277_Attachments_ChangeSet", "copyright": "This material contains content from LOINC (http://loinc.org). LOINC is copyright ©1995-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc.", "type": null, "experimental": "false", "resourceType": "CodeSystem", "title": "LOINC 2.77 Attachments Change Set for targetted redistribution", "package_version": "1.0.0-ballot", "filter": [ { "code": "parent", "value": "A Part code", "operator": [ "=" ], "description": "Allows for the selection of a set of codes based on their appearance in the LOINC Multiaxial Hierarchy. Parent selects immediate parent only. For example, the code '79190-5' has the parent 'LP379670-5'" }, { "code": "child", "value": "A comma separated list of Part or LOINC codes", "operator": [ "=" ], "description": "Allows for the selection of a set of codes based on their appearance in the LOINC Multiaxial Hierarchy. Child selects immediate children only. For example, the code 'LP379670-5' has the child '79190-5'. Only LOINC Parts have children; LOINC codes do not have any children because they are leaf nodes." }, { "code": "copyright", "value": "LOINC | 3rdParty", "operator": [ "=" ], "description": "Allows for the inclusion or exclusion of LOINC codes that include 3rd party copyright notices. LOINC = only codes with a sole copyright by Regenstrief. 3rdParty = only codes with a 3rd party copyright in addition to the one from Regenstrief" } ], "compositional": false, "status": "active", "id": "368aff8e-389f-47ef-82c1-5938bd2af63c", "kind": null, "url": "http://ikm.dev/changesets/CodeSystem/loinc277attachmentsChangeSet", "identifier": [ { "value": "urn:oid:2.16.840.1.113883.6.1", "system": "urn:ietf:rfc:3986" } ], "concept": [ { "id": "1c8f2f61-9160-46c7-9664-80ae4a5a94c3", "code": "103595-5", "display": "Cert Med Neces", "property": [ { "code": "CLASS", "valueCoding": { "code": "LP32888-7", "system": "http://loinc.org", "display": "Doc" } }, { "code": "VersionFirstReleased", "valueString": "2.77" }, { "code": "STATUS", "valueString": "ACTIVE" }, { "code": "CLASSTYPE", "valueString": "3" }, { "code": "ORDER_OBS", "valueString": "Both" }, { "code": "HL7_ATTACHMENT_STRUCTURE", "valueString": "No IG exists" }, { "code": "ValidHL7AttachmentRequest", "valueString": "Y" }, { "code": "VersionLastChanged", "valueString": "2.77" }, { "code": "COMPONENT", "valueCoding": { "code": "LP437323-1", "system": "http://loinc.org", "display": "Certificate of medical necessity" } }, { "code": "PROPERTY", "valueCoding": { "code": "LP6813-2", "system": "http://loinc.org", "display": "Find" } }, { "code": "TIME_ASPCT", "valueCoding": { "code": "LP6960-1", "system": "http://loinc.org", "display": "Pt" } }, { "code": "SYSTEM", "valueCoding": { "code": "LP310005-6", "system": "http://loinc.org", "display": "^Patient" } }, { "code": "SCALE_TYP", "valueCoding": { "code": "LP32888-7", "system": "http://loinc.org", "display": "Doc" } } ], "definition": "Certificate of Medical Necessity" }, { "id": "0ff172eb-d17d-4146-9581-ad45e4e62f0b", "code": "103596-3", "display": "DME proof of delivery", "property": [ { "code": "CLASS", "valueCoding": { "code": "LP32888-7", "system": "http://loinc.org", "display": "Doc" } }, { "code": "VersionFirstReleased", "valueString": "2.77" }, { "code": "STATUS", "valueString": "ACTIVE" }, { "code": "CLASSTYPE", "valueString": "3" }, { "code": "ORDER_OBS", "valueString": "Observation" }, { "code": "HL7_ATTACHMENT_STRUCTURE", "valueString": "No IG exists" }, { "code": "ValidHL7AttachmentRequest", "valueString": "Y" }, { "code": "VersionLastChanged", "valueString": "2.77" }, { "code": "COMPONENT", "valueCoding": { "code": "LP437553-3", "system": "http://loinc.org", "display": "Durable medical equipment proof of delivery receipt" } }, { "code": "PROPERTY", "valueCoding": { "code": "LP6813-2", "system": "http://loinc.org", "display": "Find" } }, { "code": "TIME_ASPCT", "valueCoding": { "code": "LP6960-1", "system": "http://loinc.org", "display": "Pt" } }, { "code": "SYSTEM", "valueCoding": { "code": "LP310005-6", "system": "http://loinc.org", "display": "^Patient" } }, { "code": "SCALE_TYP", "valueCoding": { "code": "LP32888-7", "system": "http://loinc.org", "display": "Doc" } } ], "definition": "Durable medical equipment proof of delivery receipt" }, { "id": "9ce55d17-eee1-412d-9ebd-8ef36c896f8b", "code": "103597-1", "display": "Pain magt form/template", "property": [ { "code": "CLASS", "valueCoding": { "code": "LP32888-7", "system": "http://loinc.org", "display": "Doc" } }, { "code": "VersionFirstReleased", "valueString": "2.77" }, { "code": "STATUS", "valueString": "ACTIVE" }, { "code": "CLASSTYPE", "valueString": "3" }, { "code": "ORDER_OBS", "valueString": "Observation" }, { "code": "HL7_ATTACHMENT_STRUCTURE", "valueString": "No IG exists" }, { "code": "ValidHL7AttachmentRequest", "valueString": "Y" }, { "code": "VersionLastChanged", "valueString": "2.77" }, { "code": "COMPONENT", "valueCoding": { "code": "LP437336-3", "system": "http://loinc.org", "display": "Pain management form or template" } }, { "code": "PROPERTY", "valueCoding": { "code": "LP6813-2", "system": "http://loinc.org", "display": "Find" } }, { "code": "TIME_ASPCT", "valueCoding": { "code": "LP6960-1", "system": "http://loinc.org", "display": "Pt" } }, { "code": "SYSTEM", "valueCoding": { "code": "LP310005-6", "system": "http://loinc.org", "display": "^Patient" } }, { "code": "SCALE_TYP", "valueCoding": { "code": "LP32888-7", "system": "http://loinc.org", "display": "Doc" } } ], "definition": "Pain management form or template" } ], "caseSensitive": false, "version": "1.0.0-ballot", "contact": [ { "telecom": [ { "value": "http://www.hl7.org/Special/committees/Vocab", "system": "url" } ] } ] }