"description": null,
"_filename": "StructureDefinition-mii-pr-icu-vent-maximaler-beatmungsdruck.json",
"package_name": "de.medizininformatikinitiative.kerndatensatz.icu",
"date": null,
"derivation": "constraint",
"publisher": "Medizininformatik Initiative",
"fhirVersion": "4.0.1",
"name": "MII_PR_ICU_Maximaler_Beatmungsdruck",
"abstract": false,
"type": "Observation",
"experimental": null,
"resourceType": "StructureDefinition",
"title": "MII PR ICU Maximaler Beatmungsdruck",
"package_version": "2026.0.0-ballot",
"status": "active",
"id": "35dc7564-5336-491a-b245-2ae0b469f0f7",
"kind": "resource",
"url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/maximaler-beatmungsdruck",
"version": "2025.0.4",
"differential": {
"element": [ {
"id": "Observation.code.coding",
"min": 3,
"path": "Observation.code.coding"
}, {
"id": "Observation.code.coding:sct",
"max": "1",
"min": 1,
"path": "Observation.code.coding",
"sliceName": "sct",
"patternCoding": {
"code": "27913002",
"system": "http://snomed.info/sct"
}
}, {
"id": "Observation.code.coding:loinc",
"max": "1",
"min": 1,
"path": "Observation.code.coding",
"sliceName": "loinc",
"patternCoding": {
"code": "76531-3",
"system": "http://loinc.org"
}
}, {
"id": "Observation.code.coding:IEEE-11073",
"max": "1",
"min": 1,
"path": "Observation.code.coding",
"sliceName": "IEEE-11073",
"patternCoding": {
"code": "151973",
"system": "urn:iso:std:iso:11073:10101"
}
}, {
"id": "Observation.effective[x]",
"min": 1,
"path": "Observation.effective[x]"
}, {
"id": "Observation.value[x]",
"path": "Observation.value[x]",
"patternQuantity": {
"code": "cm[H2O]",
"system": "http://unitsofmeasure.org"
}
} ]
},
"contact": [ {
"telecom": [ {
"value": "https://www.medizininformatik-initiative.de",
"system": "url"
} ]
} ],
"baseDefinition": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-beatmung"
}