PackagesCanonicalsLogsProblems
    Packages
    nictiz.fhir.nl.r4.zib2020@0.12.0-beta.1
    http://nictiz.nl/fhir/StructureDefinition/zib-VisualAcuity
{
  "description": "Visual acuity is a measurement of sharpness of vision. It is a measure of the smallest details that someone can still distinguish.",
  "_filename": "zib-VisualAcuity.json",
  "package_name": "nictiz.fhir.nl.r4.zib2020",
  "date": null,
  "derivation": "constraint",
  "publisher": "Nictiz",
  "fhirVersion": "4.0.1",
  "purpose": "This Observation resource represents the Dutch [zib ('Zorginformatiebouwsteen', i.e. Health and Care Information Model) VisualAcuity v1.0 (2020)](https://zibs.nl/wiki/VisualAcuity-v1.0(2020EN)).",
  "name": "ZibVisualAcuity",
  "mapping": [ {
    "uri": "https://zibs.nl/wiki/VisualAcuity-v1.0(2020EN)",
    "name": "zib VisualAcuity-v1.0(2020EN)",
    "identity": "zib-visualacuity-v1.0-2020EN"
  } ],
  "abstract": true,
  "copyright": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
  "type": "Observation",
  "experimental": null,
  "resourceType": "StructureDefinition",
  "title": "zib VisualAcuity",
  "package_version": "0.12.0-beta.1",
  "status": "draft",
  "id": "3548fae6-fde1-4010-a8bd-356a1a389b69",
  "kind": "resource",
  "url": "http://nictiz.nl/fhir/StructureDefinition/zib-VisualAcuity",
  "version": null,
  "differential": {
    "element": [ {
      "id": "Observation",
      "path": "Observation",
      "alias": [ "Visus" ],
      "short": "VisualAcuity",
      "mapping": [ {
        "map": "NL-CM:12.19.1",
        "comment": "VisualAcuity",
        "identity": "zib-visualacuity-v1.0-2020EN"
      } ]
    }, {
      "id": "Observation.code",
      "path": "Observation.code",
      "patternCodeableConcept": {
        "coding": [ {
          "code": "260246004",
          "system": "http://snomed.info/sct"
        } ]
      }
    }, {
      "id": "Observation.effective[x]",
      "path": "Observation.effective[x]",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "type"
        } ]
      }
    }, {
      "id": "Observation.effective[x]:effectiveDateTime",
      "path": "Observation.effective[x]",
      "type": [ {
        "code": "dateTime"
      } ],
      "alias": [ "VisusDatumTijd" ],
      "short": "VisualAcuityDateTime",
      "mapping": [ {
        "map": "NL-CM:12.19.4",
        "comment": "VisualAcuityDateTime",
        "identity": "zib-visualacuity-v1.0-2020EN"
      } ],
      "sliceName": "effectiveDateTime",
      "definition": "The date and time when the visual acuity was measured."
    }, {
      "id": "Observation.value[x]",
      "path": "Observation.value[x]",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "type"
        } ]
      }
    }, {
      "path": "Observation.value[x]",
      "definition": "The measured decimal visual acuity.",
      "short": "DecimalVisualAqcuity",
      "mapping": [ {
        "map": "NL-CM:12.19.11",
        "comment": "VisualAcuity",
        "identity": "zib-visualacuity-v1.0-2020EN"
      } ],
      "type": [ {
        "code": "Quantity"
      } ],
      "sliceName": "valueQuantity",
      "maxValueQuantity": {
        "code": "1",
        "value": 2,
        "system": "http://unitsofmeasure.org"
      },
      "alias": [ "DecimaleVisusWaarde" ],
      "id": "Observation.value[x]:valueQuantity",
      "comment": "Visual acuity is measured a dimensionless decimal. Therefore, a pattern with unit '1' is defined on `.valueQuantity`.",
      "patternQuantity": {
        "code": "1",
        "system": "http://unitsofmeasure.org"
      },
      "minValueQuantity": {
        "code": "1",
        "value": 0,
        "system": "http://unitsofmeasure.org"
      }
    }, {
      "id": "Observation.bodySite",
      "path": "Observation.bodySite",
      "type": [ {
        "code": "CodeableConcept",
        "profile": [ "http://nictiz.nl/fhir/StructureDefinition/zib-AnatomicalLocation" ]
      } ],
      "comment": "The code on this element is added to make explicit what is implicit in the zib. See [ZIB-1442](https://bits.nictiz.nl/browse/ZIB-1442) for details.",
      "definition": "The laterality of the eye of which the visual acuity has been measured.",
      "patternCodeableConcept": {
        "coding": [ {
          "code": "81745001",
          "system": "http://snomed.info/sct"
        } ]
      }
    }, {
      "id": "Observation.bodySite.extension:laterality",
      "path": "Observation.bodySite.extension",
      "sliceName": "laterality"
    }, {
      "id": "Observation.bodySite.extension:laterality.value[x]",
      "path": "Observation.bodySite.extension.value[x]",
      "alias": [ "AnatomischeLocatie" ],
      "short": "AnatomicalLocation",
      "mapping": [ {
        "map": "NL-CM:12.19.5",
        "comment": "AnatomicalLocation",
        "identity": "zib-visualacuity-v1.0-2020EN"
      } ],
      "definition": "The laterality of the eye of which the visual acuity has been measured."
    }, {
      "id": "Observation.device",
      "path": "Observation.device",
      "type": [ {
        "code": "Reference",
        "targetProfile": [ "http://hl7.org/fhir/StructureDefinition/Device", "http://hl7.org/fhir/StructureDefinition/DeviceMetric", "http://nictiz.nl/fhir/StructureDefinition/zib-VisualAcuity.VisualAcuityMeasurementDevice" ]
      } ]
    }, {
      "id": "Observation.component",
      "path": "Observation.component",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "code",
          "type": "value"
        } ]
      }
    }, {
      "id": "Observation.component:visualAcuityType",
      "max": "1",
      "path": "Observation.component",
      "sliceName": "visualAcuityType"
    }, {
      "id": "Observation.component:visualAcuityType.code",
      "path": "Observation.component.code",
      "patternCodeableConcept": {
        "coding": [ {
          "code": "16830007",
          "system": "http://snomed.info/sct"
        } ]
      }
    }, {
      "id": "Observation.component:visualAcuityType.value[x]",
      "path": "Observation.component.value[x]",
      "type": [ {
        "code": "CodeableConcept"
      } ],
      "alias": [ "VisusMetingType" ],
      "short": "VisualAcuityType",
      "binding": {
        "strength": "extensible",
        "valueSet": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.12.19.2--20200901000000"
      },
      "mapping": [ {
        "map": "NL-CM:12.19.2",
        "comment": "VisualAcuityType",
        "identity": "zib-visualacuity-v1.0-2020EN"
      } ],
      "definition": "Type of visual acuity measurement."
    }, {
      "id": "Observation.component:visualAcuityMeasurementChart",
      "max": "1",
      "path": "Observation.component",
      "sliceName": "visualAcuityMeasurementChart"
    }, {
      "id": "Observation.component:visualAcuityMeasurementChart.code",
      "path": "Observation.component.code",
      "patternCodeableConcept": {
        "coding": [ {
          "code": "363691001",
          "system": "http://snomed.info/sct"
        } ]
      }
    }, {
      "id": "Observation.component:visualAcuityMeasurementChart.value[x]",
      "path": "Observation.component.value[x]",
      "type": [ {
        "code": "CodeableConcept"
      } ],
      "alias": [ "VisusMetingKaart" ],
      "short": "VisualAcuityMeasurementChart",
      "binding": {
        "strength": "extensible",
        "valueSet": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.12.19.3--20200901000000"
      },
      "mapping": [ {
        "map": "NL-CM:12.19.7",
        "comment": "VisualAcuityMeasurementChart",
        "identity": "zib-visualacuity-v1.0-2020EN"
      } ],
      "definition": "The type of chart used for the visual acuity measurement."
    }, {
      "id": "Observation.component:distanceFromChart",
      "max": "1",
      "path": "Observation.component",
      "sliceName": "distanceFromChart"
    }, {
      "id": "Observation.component:distanceFromChart.code",
      "path": "Observation.component.code",
      "comment": "This code aligns with the future version of this zib. See [ZIB-1441](https://bits.nictiz.nl/browse/ZIB-1441).",
      "patternCodeableConcept": {
        "coding": [ {
          "code": "152731000146106",
          "system": "http://snomed.info/sct"
        } ]
      }
    }, {
      "id": "Observation.component:distanceFromChart.value[x]",
      "path": "Observation.component.value[x]",
      "type": [ {
        "code": "Quantity"
      } ],
      "alias": [ "AfstandTotKaart" ],
      "short": "DistanceFromChart",
      "mapping": [ {
        "map": "NL-CM:12.19.8",
        "comment": "DistanceFromChart",
        "identity": "zib-visualacuity-v1.0-2020EN"
      } ],
      "definition": "Distance to the chart in meters",
      "patternQuantity": {
        "code": "m",
        "system": "http://unitsofmeasure.org"
      }
    } ]
  },
  "contact": [ {
    "name": "Nictiz",
    "telecom": [ {
      "use": "work",
      "value": "https://www.nictiz.nl",
      "system": "url"
    } ]
  } ],
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Observation"
}