description: The blood pressure is a parameter for determining the condition of the blood circulation and is expressed in systolic and diastolic pressure in mmHg.\r\n#### Purpose\r\nBlood pressure is measured to gain an indication of the health condition of the patient’s cardiovascular system.\r\n#### Evidence Base\r\nThe local measurement of the arterial blood pressure, which acts as a surrogate for the arterial pressure in the systematic circulation. In most cases, the term ‘blood pressure' refers to the measurement of blood pressure of the arteria brachialis in the upper arm with the cuff using the Riva-Rocci method. \r\nThe protocol for this measurement comprises many details that are not general knowledge (such as the correct way to interpret Korotkoff sounds) or carried out correctly (adjusting the cuff width to a very large or small diameter of the upper arm, the right rate of descent of the mercury column, cut-off values for cardiac arrhythmias). package_name: healthdata.be.r4.cbb derivation: specialization name: HdBeBloodPressure abstract: true type: https://fhir.healthdata.be/StructureDefinition/LogicalModel/BloodPressure elements: BloodPressureDateTime: short: BloodPressureDateTime _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: 'De datum en tijd, dat de bloeddrukwaarden werden verkregen.'} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: Les date et heure auxquelles ces valeurs de tension artérielle ont été mesurées.} type: dateTime _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: BloeddrukDatumTijd} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: DateHeureTensionArtérielle} index: 7 MeasuringLocation: short: MeasuringLocation _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: Lichaamslocatie waar de bloeddruk is gemeten.} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: Localisation anatomique où la tension artérielle a été mesurée.} type: CodeableConcept _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: MeetLocatie} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: LocalisationMesure} binding: {strength: extensible, valueSet: 'https://fhir.healthdata.be/ValueSet/MeasuringLocation'} index: 2 Comment: short: Comment _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: 'Opmerkingen over de gemeten bloeddruk. Hier kan bijvoorbeeld een toelichting worden gegeven op omstandigheden die de meting hebben beïnvloed, zoals pijn, (in)spanning en slaap/waak toestand.'} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: 'Commentaires sur la tension artérielle mesurée. Une explication peut être donnée ici, par exemple, de circonstances susceptibles d''avoir influencé la tension artérielle du patient, comme la douleur, le stress, l''effort et les cycles sommeil/éveil.'} type: string _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: Toelichting} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: Commentaire} index: 8 MeasuringMethod: short: MeasuringMethod _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: De soort methode die is toegepast voor het meten van de bloeddruk.} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: Le type de méthode utilisée pour mesurer la tension artérielle.} type: CodeableConcept _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: Meetmethode} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: MéthodeMesure} binding: {strength: extensible, valueSet: 'https://fhir.healthdata.be/ValueSet/MeasuringMethod'} index: 0 SystolicBloodPressure: short: SystolicBloodPressure _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: De hoogste (piek) systemische arteriële bloeddruk - gemeten in de systolische of samentrekkingsfase van de hartslag.} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: 'La tension artérielle systémique la plus élevée (pic) en mm[Hg] - mesurée au stade de contraction ou systole du cycle cardiaque.'} type: Quantity _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: SystolischeBloeddruk} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: TensionSystolique} index: 4 CuffType: short: CuffType _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: De grootte van de manchet gebruikt bij de meting.} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: La taille du brassard utilisé pour la mesure.} type: CodeableConcept _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: ManchetType} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: TypeBrassard} binding: {strength: required, valueSet: 'https://fhir.healthdata.be/ValueSet/CuffType'} index: 1 AverageBloodPressure: short: AverageBloodPressure _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - url: content valueMarkdown: |- De gemiddelde bloeddruk gedurende één cyclus van samentrekken en ontspannen van het hart. Deze wordt geschat op basis van de boven- en onderdruk. Die schatting is onbetrouwbaar bij circulatiestoornissen. Alleen bij een invasief gemeten bloeddruk kan deze waarde betrouwbaar vastgesteld worden. - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - url: content valueMarkdown: "Tension artérielle moyenne en mm[Hg] pendant un cycle de contraction et de relaxation du cœur. \nEstimation basée sur la tension artérielle systolique et diastolique. Cette estimation n'est pas fiable en cas de troubles circulatoires. Cette valeur ne peut être déterminée de manière fiable que par une mesure invasive de la tension artérielle." type: Quantity _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: GemiddeldeBloeddruk} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: TensionArtérielleMoyenne} index: 6 Position: short: Position _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: De houding van de patiënt bij het meten van de bloeddruk.} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: La position du patient lors de la mesure de la tension artérielle.} type: CodeableConcept _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: Houding} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: Position} binding: {strength: extensible, valueSet: 'https://fhir.healthdata.be/ValueSet/MeasuringPosition'} index: 9 DiastolicBloodPressure: short: DiastolicBloodPressure _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: De laagste systemische arteriële bloeddruk - gemeten in de diastolische of ontspanningsfase van de hartslag.} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: 'La tension artérielle systémique la plus basse en mm[Hg] - mesurée au stade de relaxation ou diastole du cycle cardiaque.'} type: Quantity _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: DiastolischeBloeddruk} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: TensionDiastolique} index: 5 DiastolicEndpoint: short: DiastolicEndpoint _definition: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: Registratie van de Korotkoff toon die gebruikt is om de diastolische druk te meten met de auscultatieve methode.} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: Enregistrement des bruits de Korotkoff utilisés pour mesurer la tension diastolique avec la méthode auscultatoire.} type: CodeableConcept _short: extension: - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: nl-BE} - {url: content, valueMarkdown: DiastolischEindpunt} - url: http://hl7.org/fhir/StructureDefinition/translation extension: - {url: lang, valueCode: fr-BE} - {url: content, valueMarkdown: PointFinalDiastolique} binding: {strength: required, valueSet: 'https://fhir.healthdata.be/ValueSet/DiastolicEndpoint'} index: 3 package_version: 0.13.0-beta class: logical kind: logical url: https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-BloodPressure base: http://hl7.org/fhir/StructureDefinition/Element version: null required: [BloodPressureDateTime, SystolicBloodPressure, DiastolicBloodPressure]