PackagesCanonicalsLogsProblems
    Packages
    de.medizininformatikinitiative.kerndatensatz.bildgebung@2025.0.0-ballot
    https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-series-uid
{
  "description": "Die Extension ermöglicht es, den Bildnummer aus dem entsprechenden DICOM Tag auf Studien-Ebene anzugeben.",
  "_filename": "StructureDefinition-mii-ex-bildgebung-serie-uid.json",
  "package_name": "de.medizininformatikinitiative.kerndatensatz.bildgebung",
  "date": null,
  "derivation": "constraint",
  "publisher": "Medizininformatik Initiative",
  "fhirVersion": "4.0.1",
  "name": "MII_EX_Bildgebung_Serie_UID",
  "abstract": false,
  "type": "Extension",
  "experimental": "false",
  "resourceType": "StructureDefinition",
  "title": "MII EX Bildgebung Bildnummer",
  "_description": {
    "extension": [ {
      "url": "http://hl7.org/fhir/StructureDefinition/translation",
      "extension": [ {
        "url": "lang",
        "valueCode": "en-US"
      }, {
        "url": "content",
        "valueString": "The extension allows specifying the reason for the imaging procedure from the corresponding DICOM tag at the study level."
      } ]
    } ]
  },
  "package_version": "2025.0.0-ballot",
  "status": "active",
  "id": "1d7c095d-192f-476d-844b-dff25fa80df4",
  "kind": "complex-type",
  "_name": {
    "extension": [ {
      "url": "http://hl7.org/fhir/StructureDefinition/translation",
      "extension": [ {
        "url": "lang",
        "valueCode": "en-US"
      }, {
        "url": "content",
        "valueString": "MII_EX_Imaging_Imagenumber"
      } ]
    } ]
  },
  "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-series-uid",
  "context": [ {
    "type": "element",
    "expression": "Observation"
  } ],
  "_title": {
    "extension": [ {
      "url": "http://hl7.org/fhir/StructureDefinition/translation",
      "extension": [ {
        "url": "lang",
        "valueCode": "en-US"
      }, {
        "url": "content",
        "valueString": "MII EX Imaging Imagenumber"
      } ]
    } ]
  },
  "version": "2025.0.0-ballot",
  "differential": {
    "element": [ {
      "id": "Extension.extension",
      "max": "0",
      "path": "Extension.extension"
    }, {
      "id": "Extension.url",
      "path": "Extension.url",
      "fixedUri": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-series-uid"
    }, {
      "id": "Extension.value[x]",
      "path": "Extension.value[x]",
      "type": [ {
        "code": "id"
      } ]
    } ]
  },
  "contact": [ {
    "telecom": [ {
      "value": "https://www.medizininformatik-initiative.de",
      "system": "url"
    } ]
  } ],
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension"
}