PackagesCanonicalsLogsProblems
    Packages
    lt.hl7.fhir.vitalsigns@0.0.1
    https://hl7.lt/fhir/vitalsigns/StructureDefinition/body-structure-blood-pressure
description: Body Structure profile to describe where on the body a blood pressure measurement was taken.
package_name: lt.hl7.fhir.vitalsigns
derivation: constraint
name: BodyStructureBloodPressure
type: BodyStructure
elements:
  includedStructure:
    mustSupport: true
    index: 0
    elements:
      structure:
        short: A set of codes that describe site where on/in the body an observation or procedure took place
        binding: {strength: required, valueSet: 'https://hl7.lt/fhir/vitalsigns/ValueSet/bp-measurement-body-location|2.0.0'}
        mustSupport: true
        index: 1
      laterality: {short: Laterality, mustSupport: true, index: 2}
      bodyLandmarkOrientation:
        index: 3
        elements:
          landmarkDescription:
            short: Body Position
            binding: {strength: extensible, valueSet: 'https://hl7.lt/fhir/vitalsigns/ValueSet/vital-signs-body-position|1.0.0'}
            mustSupport: true
            index: 4
        required: [landmarkDescription]
package_version: 0.0.1
class: profile
kind: resource
url: https://hl7.lt/fhir/vitalsigns/StructureDefinition/body-structure-blood-pressure
base: http://hl7.eu/fhir/base-r5/StructureDefinition/bodyStructure-eu-core|0.1.0
version: 0.0.1