PackagesCanonicalsLogsProblems
    Packages
    de.gecco@1.0.4-rc.3
    https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure
{
  "description": "The blood pressure of a patient.",
  "_filename": "Profile-Observation-BloodPressure.json",
  "package_name": "de.gecco",
  "date": "2021-05-17",
  "derivation": "constraint",
  "publisher": "Charité",
  "fhirVersion": "4.0.1",
  "name": "BloodPressure",
  "mapping": [ {
    "uri": "http://hl7.org/fhir/workflow",
    "name": "Workflow Pattern",
    "identity": "workflow"
  }, {
    "uri": "http://snomed.info/conceptdomain",
    "name": "SNOMED CT Concept Domain Binding",
    "identity": "sct-concept"
  }, {
    "uri": "http://hl7.org/v2",
    "name": "HL7 v2 Mapping",
    "identity": "v2"
  }, {
    "uri": "http://hl7.org/v3",
    "name": "RIM Mapping",
    "identity": "rim"
  }, {
    "uri": "http://hl7.org/fhir/fivews",
    "name": "FiveWs Pattern Mapping",
    "identity": "w5"
  }, {
    "uri": "http://snomed.org/attributebinding",
    "name": "SNOMED CT Attribute Binding",
    "identity": "sct-attr"
  } ],
  "abstract": false,
  "type": "Observation",
  "experimental": null,
  "resourceType": "StructureDefinition",
  "title": "Blood Pressure",
  "package_version": "1.0.4-rc.3",
  "extension": [ {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-category",
    "valueString": "Clinical.Diagnostics"
  }, {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-security-category",
    "valueCode": "patient"
  } ],
  "status": "active",
  "id": "13e4554f-8d3f-4052-9270-f573523a0f26",
  "kind": "resource",
  "url": "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure",
  "version": "1.0.4",
  "differential": {
    "element": [ {
      "id": "Observation.code.coding",
      "min": 1,
      "path": "Observation.code.coding",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "pattern"
        } ]
      }
    }, {
      "id": "Observation.code.coding:loinc",
      "max": "*",
      "min": 1,
      "path": "Observation.code.coding",
      "sliceName": "loinc",
      "patternCoding": {
        "code": "85354-9",
        "system": "http://loinc.org"
      }
    }, {
      "id": "Observation.code.coding:loinc.system",
      "min": 1,
      "path": "Observation.code.coding.system"
    }, {
      "id": "Observation.code.coding:loinc.code",
      "min": 1,
      "path": "Observation.code.coding.code"
    }, {
      "id": "Observation.code.coding:snomed",
      "max": "*",
      "min": 0,
      "path": "Observation.code.coding",
      "sliceName": "snomed",
      "patternCoding": {
        "code": "75367002",
        "system": "http://snomed.info/sct"
      }
    }, {
      "id": "Observation.code.coding:snomed.system",
      "min": 1,
      "path": "Observation.code.coding.system"
    }, {
      "id": "Observation.code.coding:snomed.code",
      "min": 1,
      "path": "Observation.code.coding.code"
    }, {
      "id": "Observation.value[x]",
      "max": "0",
      "path": "Observation.value[x]"
    }, {
      "id": "Observation.component",
      "min": 2,
      "path": "Observation.component",
      "short": "Used when reporting systolic and diastolic blood pressure.",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "code",
          "type": "pattern"
        } ]
      },
      "constraint": [ {
        "key": "vs-3",
        "human": "If there is no a value a data absent reason must be present",
        "xpath": "f:*[starts-with(local-name(.), 'value')] or f:dataAbsentReason",
        "source": "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure",
        "severity": "error",
        "expression": "value.exists() or dataAbsentReason.exists()"
      } ],
      "definition": "Used when reporting systolic and diastolic blood pressure.",
      "mustSupport": true
    }, {
      "id": "Observation.component:systolicBloodPressure",
      "max": "1",
      "min": 1,
      "path": "Observation.component",
      "short": "Systolic blood pressure",
      "sliceName": "systolicBloodPressure",
      "mustSupport": true
    }, {
      "id": "Observation.component:systolicBloodPressure.code",
      "path": "Observation.component.code",
      "mustSupport": true,
      "patternCodeableConcept": {
        "coding": [ {
          "code": "8480-6",
          "system": "http://loinc.org"
        } ]
      }
    }, {
      "id": "Observation.component:systolicBloodPressure.code.coding",
      "min": 1,
      "path": "Observation.component.code.coding",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "pattern"
        } ]
      }
    }, {
      "id": "Observation.component:systolicBloodPressure.code.coding:loinc",
      "max": "*",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "loinc",
      "patternCoding": {
        "code": "8480-6",
        "system": "http://loinc.org"
      }
    }, {
      "id": "Observation.component:systolicBloodPressure.code.coding:loinc.system",
      "min": 1,
      "path": "Observation.component.code.coding.system"
    }, {
      "id": "Observation.component:systolicBloodPressure.code.coding:loinc.code",
      "min": 1,
      "path": "Observation.component.code.coding.code"
    }, {
      "id": "Observation.component:systolicBloodPressure.code.coding:snomed",
      "max": "*",
      "min": 0,
      "path": "Observation.component.code.coding",
      "sliceName": "snomed",
      "patternCoding": {
        "code": "271649006",
        "system": "http://snomed.info/sct"
      }
    }, {
      "id": "Observation.component:systolicBloodPressure.code.coding:snomed.system",
      "min": 1,
      "path": "Observation.component.code.coding.system"
    }, {
      "id": "Observation.component:systolicBloodPressure.code.coding:snomed.code",
      "min": 1,
      "path": "Observation.component.code.coding.code"
    }, {
      "id": "Observation.component:systolicBloodPressure.value[x]",
      "path": "Observation.component.value[x]",
      "type": [ {
        "code": "Quantity"
      } ],
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "type"
        } ]
      },
      "mustSupport": true
    }, {
      "id": "Observation.component:systolicBloodPressure.valueQuantity",
      "max": "1",
      "min": 0,
      "path": "Observation.component.valueQuantity",
      "short": "Systolic blood pressure value",
      "mustSupport": true
    }, {
      "id": "Observation.component:systolicBloodPressure.valueQuantity.value",
      "min": 1,
      "path": "Observation.component.valueQuantity.value"
    }, {
      "id": "Observation.component:systolicBloodPressure.valueQuantity.unit",
      "min": 1,
      "path": "Observation.component.valueQuantity.unit"
    }, {
      "id": "Observation.component:systolicBloodPressure.valueQuantity.system",
      "min": 1,
      "path": "Observation.component.valueQuantity.system",
      "patternUri": "http://unitsofmeasure.org"
    }, {
      "id": "Observation.component:systolicBloodPressure.valueQuantity.code",
      "min": 1,
      "path": "Observation.component.valueQuantity.code",
      "patternCode": "mm[Hg]"
    }, {
      "id": "Observation.component:diastolicBloodPressure",
      "max": "1",
      "min": 1,
      "path": "Observation.component",
      "short": "Diastolic blood pressure",
      "sliceName": "diastolicBloodPressure",
      "mustSupport": true
    }, {
      "id": "Observation.component:diastolicBloodPressure.code",
      "path": "Observation.component.code",
      "mustSupport": true,
      "patternCodeableConcept": {
        "coding": [ {
          "code": "8462-4",
          "system": "http://loinc.org"
        } ]
      }
    }, {
      "id": "Observation.component:diastolicBloodPressure.code.coding",
      "min": 1,
      "path": "Observation.component.code.coding",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "pattern"
        } ]
      }
    }, {
      "id": "Observation.component:diastolicBloodPressure.code.coding:loinc",
      "max": "*",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "loinc",
      "patternCoding": {
        "code": "8462-4",
        "system": "http://loinc.org"
      }
    }, {
      "id": "Observation.component:diastolicBloodPressure.code.coding:loinc.system",
      "min": 1,
      "path": "Observation.component.code.coding.system"
    }, {
      "id": "Observation.component:diastolicBloodPressure.code.coding:loinc.code",
      "min": 1,
      "path": "Observation.component.code.coding.code"
    }, {
      "id": "Observation.component:diastolicBloodPressure.code.coding:snomed",
      "max": "*",
      "min": 0,
      "path": "Observation.component.code.coding",
      "sliceName": "snomed",
      "patternCoding": {
        "code": "271650006",
        "system": "http://snomed.info/sct"
      }
    }, {
      "id": "Observation.component:diastolicBloodPressure.code.coding:snomed.system",
      "min": 1,
      "path": "Observation.component.code.coding.system"
    }, {
      "id": "Observation.component:diastolicBloodPressure.code.coding:snomed.code",
      "min": 1,
      "path": "Observation.component.code.coding.code"
    }, {
      "id": "Observation.component:diastolicBloodPressure.value[x]",
      "path": "Observation.component.value[x]",
      "type": [ {
        "code": "Quantity"
      } ],
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "type"
        } ]
      },
      "mustSupport": true
    }, {
      "id": "Observation.component:diastolicBloodPressure.valueQuantity",
      "max": "1",
      "min": 0,
      "path": "Observation.component.valueQuantity",
      "short": "Diastolic blood pressure value",
      "mustSupport": true
    }, {
      "id": "Observation.component:diastolicBloodPressure.valueQuantity.value",
      "min": 1,
      "path": "Observation.component.valueQuantity.value"
    }, {
      "id": "Observation.component:diastolicBloodPressure.valueQuantity.unit",
      "min": 1,
      "path": "Observation.component.valueQuantity.unit"
    }, {
      "id": "Observation.component:diastolicBloodPressure.valueQuantity.system",
      "min": 1,
      "path": "Observation.component.valueQuantity.system",
      "patternUri": "http://unitsofmeasure.org"
    }, {
      "id": "Observation.component:diastolicBloodPressure.valueQuantity.code",
      "min": 1,
      "path": "Observation.component.valueQuantity.code",
      "patternCode": "mm[Hg]"
    } ]
  },
  "contact": [ {
    "telecom": [ {
      "value": "https://www.bihealth.org/en/research/core-facilities/interoperability/",
      "system": "url"
    } ]
  } ],
  "baseDefinition": "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/vital-signs-base"
}