PackagesCanonicalsLogsProblems
    Packages
    de.medizininformatikinitiative.kerndatensatz.icu@2025.0.4
    https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/arterieller-blutdruck
{
  "description": null,
  "_filename": "sd-mii-icu-muv-arterieller-blutdruck.json",
  "package_name": "de.medizininformatikinitiative.kerndatensatz.icu",
  "date": null,
  "derivation": "constraint",
  "publisher": null,
  "fhirVersion": "4.0.1",
  "name": "SD_MII_ICU_Arterieller_Blutdruck",
  "abstract": false,
  "type": "Observation",
  "experimental": null,
  "resourceType": "StructureDefinition",
  "title": "SD MII ICU Arterieller Blutdruck",
  "package_version": "2025.0.4",
  "status": "active",
  "id": "0cdb12da-0d35-4b39-9dc6-f19d93d6f2ef",
  "kind": "resource",
  "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/arterieller-blutdruck",
  "version": "2025.0.4",
  "differential": {
    "element": [ {
      "id": "Observation.category",
      "path": "Observation.category",
      "mustSupport": true
    }, {
      "id": "Observation.code",
      "path": "Observation.code",
      "mustSupport": true
    }, {
      "id": "Observation.code.coding",
      "path": "Observation.code.coding",
      "mustSupport": true
    }, {
      "id": "Observation.code.coding:loinc",
      "path": "Observation.code.coding",
      "sliceName": "loinc",
      "mustSupport": true
    }, {
      "id": "Observation.code.coding:loinc.system",
      "path": "Observation.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.code.coding:loinc.code",
      "path": "Observation.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.code.coding:loinc.display",
      "path": "Observation.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.code.coding:sct",
      "max": "1",
      "min": 1,
      "path": "Observation.code.coding",
      "sliceName": "sct",
      "mustSupport": true,
      "patternCoding": {
        "code": "364090009",
        "system": "http://snomed.info/sct"
      }
    }, {
      "id": "Observation.code.coding:sct.system",
      "min": 1,
      "path": "Observation.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.code.coding:sct.version",
      "path": "Observation.code.coding.version",
      "patternString": "http://snomed.info/sct/900000000000207008/version/20241101"
    }, {
      "id": "Observation.code.coding:sct.code",
      "min": 1,
      "path": "Observation.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.code.coding:sct.display",
      "path": "Observation.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.subject",
      "path": "Observation.subject",
      "mustSupport": true
    }, {
      "id": "Observation.encounter",
      "path": "Observation.encounter",
      "mustSupport": true
    }, {
      "id": "Observation.effective[x]",
      "path": "Observation.effective[x]",
      "mustSupport": true
    }, {
      "id": "Observation.value[x]",
      "path": "Observation.value[x]",
      "mustSupport": true
    }, {
      "id": "Observation.dataAbsentReason",
      "max": "0",
      "path": "Observation.dataAbsentReason",
      "mustSupport": true
    }, {
      "id": "Observation.interpretation",
      "path": "Observation.interpretation",
      "mustSupport": true
    }, {
      "id": "Observation.bodySite",
      "path": "Observation.bodySite",
      "mustSupport": true
    }, {
      "id": "Observation.method",
      "path": "Observation.method",
      "mustSupport": true
    }, {
      "id": "Observation.device",
      "path": "Observation.device",
      "mustSupport": true
    }, {
      "id": "Observation.referenceRange",
      "max": "1",
      "path": "Observation.referenceRange",
      "mustSupport": true
    }, {
      "id": "Observation.component",
      "max": "3",
      "path": "Observation.component",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP",
      "path": "Observation.component",
      "sliceName": "SystolicBP",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.code.coding",
      "min": 3,
      "path": "Observation.component.code.coding",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "pattern"
        } ]
      }
    }, {
      "id": "Observation.component:SystolicBP.code.coding:loinc",
      "max": "1",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "loinc",
      "mustSupport": true,
      "patternCoding": {
        "code": "8480-6",
        "system": "http://loinc.org"
      }
    }, {
      "id": "Observation.component:SystolicBP.code.coding:loinc.system",
      "min": 1,
      "path": "Observation.component.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.code.coding:loinc.code",
      "min": 1,
      "path": "Observation.component.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.code.coding:loinc.display",
      "path": "Observation.component.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.code.coding:sct",
      "max": "1",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "sct",
      "mustSupport": true,
      "patternCoding": {
        "code": "271649006",
        "system": "http://snomed.info/sct"
      }
    }, {
      "id": "Observation.component:SystolicBP.code.coding:sct.system",
      "min": 1,
      "path": "Observation.component.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.code.coding:sct.code",
      "min": 1,
      "path": "Observation.component.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.code.coding:sct.display",
      "path": "Observation.component.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.code.coding:IEEE-11073",
      "max": "1",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "IEEE-11073",
      "mustSupport": true,
      "patternCoding": {
        "code": "150017",
        "system": "urn:iso:std:iso:11073:10101"
      }
    }, {
      "id": "Observation.component:SystolicBP.code.coding:IEEE-11073.system",
      "min": 1,
      "path": "Observation.component.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.code.coding:IEEE-11073.code",
      "min": 1,
      "path": "Observation.component.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.code.coding:IEEE-11073.display",
      "path": "Observation.component.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.value[x]",
      "path": "Observation.component.value[x]",
      "mustSupport": true,
      "patternQuantity": {
        "code": "mm[Hg]",
        "unit": "millimeter Mercury column",
        "system": "http://unitsofmeasure.org"
      }
    }, {
      "id": "Observation.component:SystolicBP.value[x].value",
      "min": 1,
      "path": "Observation.component.value[x].value",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.value[x].unit",
      "min": 1,
      "path": "Observation.component.value[x].unit",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.value[x].system",
      "min": 1,
      "path": "Observation.component.value[x].system",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.value[x].code",
      "min": 1,
      "path": "Observation.component.value[x].code",
      "mustSupport": true
    }, {
      "id": "Observation.component:SystolicBP.dataAbsentReason",
      "path": "Observation.component.dataAbsentReason",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP",
      "path": "Observation.component",
      "sliceName": "DiastolicBP",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.code.coding",
      "min": 3,
      "path": "Observation.component.code.coding",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "pattern"
        } ]
      }
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:loinc",
      "max": "1",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "loinc",
      "mustSupport": true,
      "patternCoding": {
        "code": "8462-4",
        "system": "http://loinc.org"
      }
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:loinc.system",
      "min": 1,
      "path": "Observation.component.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:loinc.code",
      "min": 1,
      "path": "Observation.component.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:loinc.display",
      "path": "Observation.component.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:sct",
      "max": "1",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "sct",
      "mustSupport": true,
      "patternCoding": {
        "code": "271650006",
        "system": "http://snomed.info/sct"
      }
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:sct.system",
      "min": 1,
      "path": "Observation.component.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:sct.code",
      "min": 1,
      "path": "Observation.component.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:sct.display",
      "path": "Observation.component.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:IEEE-11073",
      "max": "1",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "IEEE-11073",
      "mustSupport": true,
      "patternCoding": {
        "code": "150018",
        "system": "urn:iso:std:iso:11073:10101"
      }
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:IEEE-11073.system",
      "min": 1,
      "path": "Observation.component.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:IEEE-11073.code",
      "min": 1,
      "path": "Observation.component.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.code.coding:IEEE-11073.display",
      "path": "Observation.component.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.value[x]",
      "path": "Observation.component.value[x]",
      "mustSupport": true,
      "patternQuantity": {
        "code": "mm[Hg]",
        "unit": "millimeter Mercury column",
        "system": "http://unitsofmeasure.org"
      }
    }, {
      "id": "Observation.component:DiastolicBP.value[x].value",
      "min": 1,
      "path": "Observation.component.value[x].value",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.value[x].unit",
      "min": 1,
      "path": "Observation.component.value[x].unit",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.value[x].system",
      "min": 1,
      "path": "Observation.component.value[x].system",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.value[x].code",
      "min": 1,
      "path": "Observation.component.value[x].code",
      "mustSupport": true
    }, {
      "id": "Observation.component:DiastolicBP.dataAbsentReason",
      "path": "Observation.component.dataAbsentReason",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP",
      "path": "Observation.component",
      "sliceName": "meanBP",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.code.coding",
      "min": 3,
      "path": "Observation.component.code.coding",
      "slicing": {
        "rules": "open",
        "discriminator": [ {
          "path": "$this",
          "type": "pattern"
        } ]
      }
    }, {
      "id": "Observation.component:meanBP.code.coding:loinc",
      "max": "1",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "loinc",
      "mustSupport": true,
      "patternCoding": {
        "code": "8478-0",
        "system": "http://loinc.org"
      }
    }, {
      "id": "Observation.component:meanBP.code.coding:loinc.system",
      "min": 1,
      "path": "Observation.component.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.code.coding:loinc.code",
      "min": 1,
      "path": "Observation.component.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.code.coding:loinc.display",
      "path": "Observation.component.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.code.coding:sct",
      "max": "1",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "sct",
      "mustSupport": true,
      "patternCoding": {
        "code": "6797001",
        "system": "http://snomed.info/sct"
      }
    }, {
      "id": "Observation.component:meanBP.code.coding:sct.system",
      "min": 1,
      "path": "Observation.component.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.code.coding:sct.code",
      "min": 1,
      "path": "Observation.component.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.code.coding:sct.display",
      "path": "Observation.component.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.code.coding:IEEE-11073",
      "max": "1",
      "min": 1,
      "path": "Observation.component.code.coding",
      "sliceName": "IEEE-11073",
      "mustSupport": true,
      "patternCoding": {
        "code": "150019",
        "system": "urn:iso:std:iso:11073:10101"
      }
    }, {
      "id": "Observation.component:meanBP.code.coding:IEEE-11073.system",
      "min": 1,
      "path": "Observation.component.code.coding.system",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.code.coding:IEEE-11073.code",
      "min": 1,
      "path": "Observation.component.code.coding.code",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.code.coding:IEEE-11073.display",
      "path": "Observation.component.code.coding.display",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.value[x]",
      "path": "Observation.component.value[x]",
      "mustSupport": true,
      "patternQuantity": {
        "code": "mm[Hg]",
        "unit": "millimeter Mercury column",
        "system": "http://unitsofmeasure.org"
      }
    }, {
      "id": "Observation.component:meanBP.value[x].value",
      "min": 1,
      "path": "Observation.component.value[x].value",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.value[x].unit",
      "min": 1,
      "path": "Observation.component.value[x].unit",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.value[x].system",
      "min": 1,
      "path": "Observation.component.value[x].system",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.value[x].code",
      "min": 1,
      "path": "Observation.component.value[x].code",
      "mustSupport": true
    }, {
      "id": "Observation.component:meanBP.dataAbsentReason",
      "path": "Observation.component.dataAbsentReason",
      "mustSupport": true
    } ]
  },
  "baseDefinition": "http://fhir.de/StructureDefinition/observation-de-vitalsign-blutdruck"
}