{ "description": "Proposed constraints and extensions on JCPM Blood Pressure Resource", "_filename": "StructureDefinition-jcpm-obs-bp.json", "package_name": "fhir.outburn.co.il", "date": null, "derivation": "constraint", "publisher": null, "fhirVersion": "4.0.1", "name": "JCPMObservationBloodPressure", "mapping": [ { "uri": "http://hl7.org/fhir/workflow", "name": "Workflow Pattern", "identity": "workflow" }, { "uri": "http://snomed.info/conceptdomain", "name": "SNOMED CT Concept Domain Binding", "identity": "sct-concept" }, { "uri": "http://hl7.org/v2", "name": "HL7 v2 Mapping", "identity": "v2" }, { "uri": "http://hl7.org/v3", "name": "RIM Mapping", "identity": "rim" }, { "uri": "http://hl7.org/fhir/fivews", "name": "FiveWs Pattern Mapping", "identity": "w5" }, { "uri": "http://snomed.org/attributebinding", "name": "SNOMED CT Attribute Binding", "identity": "sct-attr" } ], "abstract": false, "type": "Observation", "experimental": null, "resourceType": "StructureDefinition", "title": "JCPM Observation Blood pressure Profile", "package_version": "0.5.5", "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-category", "valueString": "Clinical.Diagnostics" }, { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-security-category", "valueCode": "patient" } ], "status": "active", "id": "09036285-f907-453f-b038-c6d29266c8e6", "kind": "resource", "url": "http://fhir.outburn.co.il/StructureDefinition/jcpm-obs-bp", "version": "0.3.0", "differential": { "element": [ { "id": "Observation.category", "max": "1", "min": 1, "path": "Observation.category" }, { "id": "Observation.category.coding", "min": 1, "path": "Observation.category.coding" }, { "id": "Observation.category.coding.system", "min": 1, "path": "Observation.category.coding.system", "fixedUri": "http://terminology.hl7.org/CodeSystem/observation-category" }, { "id": "Observation.category.coding.code", "min": 1, "path": "Observation.category.coding.code", "fixedCode": "vital-signs" }, { "id": "Observation.category.coding.display", "path": "Observation.category.coding.display", "fixedString": "Vital Signs" }, { "id": "Observation.code", "path": "Observation.code", "short": "Blood Pressure", "mustSupport": true, "patternCodeableConcept": { "coding": [ { "code": "85354-9", "system": "http://loinc.org" } ] } }, { "id": "Observation.subject", "min": 1, "path": "Observation.subject", "type": [ { "code": "Reference", "targetProfile": [ "http://fhir.outburn.co.il/StructureDefinition/jcpm-patient" ] } ] }, { "id": "Observation.encounter", "min": 1, "path": "Observation.encounter", "type": [ { "code": "Reference", "targetProfile": [ "http://fhir.outburn.co.il/StructureDefinition/jcpm-enc-delivery", "http://fhir.outburn.co.il/StructureDefinition/jcpm-enc-pregnancy" ] } ] }, { "id": "Observation.component", "min": 2, "path": "Observation.component", "slicing": { "rules": "open", "ordered": false, "discriminator": [ { "path": "code", "type": "pattern" } ] }, "mustSupport": true }, { "id": "Observation.component:systolic", "max": "1", "min": 1, "path": "Observation.component", "short": "Systolic Blood Pressure", "sliceName": "systolic", "mustSupport": true }, { "id": "Observation.component:systolic.code", "path": "Observation.component.code", "short": "Systolic Blood Pressure Code", "mustSupport": true, "patternCodeableConcept": { "coding": [ { "code": "8480-6", "system": "http://loinc.org" } ] } }, { "id": "Observation.component:systolic.valueQuantity", "max": "1", "min": 0, "path": "Observation.component.valueQuantity", "type": [ { "code": "Quantity" } ], "mustSupport": true }, { "id": "Observation.component:systolic.valueQuantity.value", "min": 1, "path": "Observation.component.valueQuantity.value", "mustSupport": true }, { "id": "Observation.component:systolic.valueQuantity.unit", "min": 1, "path": "Observation.component.valueQuantity.unit", "mustSupport": true }, { "id": "Observation.component:systolic.valueQuantity.system", "min": 1, "path": "Observation.component.valueQuantity.system", "fixedUri": "http://unitsofmeasure.org", "mustSupport": true }, { "id": "Observation.component:systolic.valueQuantity.code", "min": 1, "path": "Observation.component.valueQuantity.code", "fixedCode": "mm[Hg]", "mustSupport": true }, { "id": "Observation.component:diastolic", "max": "1", "min": 1, "path": "Observation.component", "short": "Diastolic Blood Pressure", "sliceName": "diastolic", "mustSupport": true }, { "id": "Observation.component:diastolic.code", "path": "Observation.component.code", "short": "Diastolic Blood Pressure Code", "mustSupport": true, "patternCodeableConcept": { "coding": [ { "code": "8462-4", "system": "http://loinc.org" } ] } }, { "id": "Observation.component:diastolic.valueQuantity", "max": "1", "min": 0, "path": "Observation.component.valueQuantity", "type": [ { "code": "Quantity" } ], "mustSupport": true }, { "id": "Observation.component:diastolic.valueQuantity.value", "min": 1, "path": "Observation.component.valueQuantity.value", "mustSupport": true }, { "id": "Observation.component:diastolic.valueQuantity.unit", "min": 1, "path": "Observation.component.valueQuantity.unit", "mustSupport": true }, { "id": "Observation.component:diastolic.valueQuantity.system", "min": 1, "path": "Observation.component.valueQuantity.system", "fixedUri": "http://unitsofmeasure.org", "mustSupport": true }, { "id": "Observation.component:diastolic.valueQuantity.code", "min": 1, "path": "Observation.component.valueQuantity.code", "fixedCode": "mm[Hg]", "mustSupport": true } ] }, "contact": [ { "name": "Outburn LTD", "telecom": [ { "value": "http://outburn.co.il", "system": "url" } ] } ], "baseDefinition": "http://fhir.health.gov.il/StructureDefinition/il-core-observation" }