"description": "Servers are encouraged to implement OAuth 2.0 access management in accordance with the [SMART Backend Services: Authorization Guide](https://hl7.org/fhir/smart-app-launch/backend-services.html). Implementations MAY include non-RESTful services that use authorization schemes other than OAuth 2.0, such as mutual-TLS or signed URLs.",
"_filename": "CapabilityStatement-SelectiveSupplier - BulkExport.json",
"package_name": "ca.infoway.io.ca-csd",
"format": [ "application/fhir+xml", "application/fhir+json" ],
"date": null,
"publisher": "Canada Health Infoway",
"fhirVersion": "4.0.1",
"name": "CA_CSD_Care_Services_Selective_Supplier_BulkExport",
"copyright": "Copyright © 2024+ Canada Health Infoway. All rights reserved. [Terms of Use and License Agreements](https://ic.infoway-inforoute.ca/en/about/tou). [Privacy Policy](https://www.infoway-inforoute.ca/en/legal/privacy-policy).",
"type": null,
"experimental": null,
"resourceType": "CapabilityStatement",
"title": "CA:CSD Care Services Selective Supplier BulkExport",
"package_version": "1.1.1-dft-preBallot",
"status": "draft",
"id": "07da2c3b-f27b-4738-a56f-4cd19ce1e0b4",
"kind": "requirements",
"url": "http://fhir.infoway-inforoute.ca/io/CA-CSD/CapabilityStatement/CA-CSD-CareServicesSelectiveSupplier-BulkExport",
"version": null,
"contact": [ {
"name": "Canada Health Infoway",
"telecom": [ {
"value": "interoperability@infoway-inforoute.ca",
"system": "email"
} ]
} ],
"rest": [ {
"mode": "client",
"resource": [ {
"type": "HealthcareService",
"interaction": [ {
"code": "search-type",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
}, {
"code": "read",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
} ],
"supportedProfile": [ "http://fhir.infoway-inforoute.ca/io/CA-CSD/StructureDefinition/CA-CSD-HealthcareService" ]
}, {
"type": "Location",
"interaction": [ {
"code": "search-type",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
}, {
"code": "read",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
} ],
"supportedProfile": [ "http://fhir.infoway-inforoute.ca/io/CA-CSD/StructureDefinition/CA-CSD-Location" ]
}, {
"type": "Organization",
"interaction": [ {
"code": "search-type",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
}, {
"code": "read",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
} ],
"supportedProfile": [ "http://fhir.infoway-inforoute.ca/io/CA-CSD/StructureDefinition/CA-CSD-Organization" ]
}, {
"type": "OrganizationAffiliation",
"interaction": [ {
"code": "search-type",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
}, {
"code": "read",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
} ],
"supportedProfile": [ "http://fhir.infoway-inforoute.ca/io/CA-CSD/StructureDefinition/CA-CSD-OrganizationAffiliation" ]
}, {
"type": "Practitioner",
"interaction": [ {
"code": "search-type",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
}, {
"code": "read",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
} ],
"supportedProfile": [ "http://fhir.infoway-inforoute.ca/io/CA-CSD/StructureDefinition/CA-CSD-Practitioner" ]
}, {
"type": "PractitionerRole",
"interaction": [ {
"code": "search-type",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
}, {
"code": "read",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHOULD"
} ]
} ],
"supportedProfile": [ "http://fhir.infoway-inforoute.ca/io/CA-CSD/StructureDefinition/CA-CSD-PractitionerRole" ]
} ],
"security": {
"description": "Servers are required to implement OAuth 2.0 access management for bulk data export in accordance with the SMART Backend Services: Authorization Guide. Implementations MAY also support alternative authentication mechanisms such as mutual-TLS or signed URLs."
},
"operation": [ {
"name": "bulk-export",
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation",
"valueCode": "SHALL"
} ],
"definition": "http://fhir.infoway-inforoute.ca/io/CA-CSD/OperationDefinition/bulk-export",
"documentation": "FHIR Operation to export data from a FHIR server. This supports use cases like backing up a server, or exporting terminology data by restricting the resources returned using the `_type` parameter."
} ]
} ]
}